← All training manualsBoreholes and Water Pumps · read-onlyGet the PDF with Teacher Copy (GH¢50)
Training module · National Proficiency I · CTVET formatTrainee Manual

Boreholes and Water Pumps

Clean water from the ground, safely and legally. Learn how a borehole works, how pumps lift the water, how to keep it clean, and how to start earning from pump care and repair.

A borehole cut open: casing, submersible pump, tank, solar panel and a hand pump A cross-section of the ground. A narrow cased borehole goes down through soil and rock to a blue water table. A submersible pump hangs near the bottom on a pipe that rises to a tank on a steel stand on the left. A solar panel on a frame stands beside the tank. On the right, a hand pump with a long handle stands over a second borehole, and a person fills a yellow bucket at its spout. TANK + SOLARPUMPHAND PUMPSAFE WATER · LICENSED DRILLERS
Trainee name
Training centre
Start date
Instructor
Prepared by De-Graft Afful · Version 1.1.0 · November 2026
01

About this module

Clean water is the first thing a home, a farm or a school needs. A borehole gives it, but only if the borehole is sited, drilled, pumped and kept clean by people who know their work. This module teaches you the basics so you can help, learn more and earn.

Who it is for. People with no formal certificate, aged 18 or over. National Proficiency I is a bridging level for people with little or no formal education; holders do routine tasks under supervision. In Ghana, nobody under 18 may do hazardous work.

Why boreholes and pumps

  • Rural and small-town water in Ghana depends heavily on boreholes. At its Western Region 25th anniversary in 2024, the Community Water and Sanitation Agency (CWSA) said it oversees 31,388 boreholes with hand pumps, 383 solar boreholes and 1,924 piped systems nationwide.
  • Every pump, tank and hand pump needs someone to look after it. A hand-pump committee that has no mechanic nearby waits days for repairs.
  • The Hub (HSM Agrictech and Innovation Hub) uses water for its farm, so you will see real tanks and pipes while you train.

This module is not a CTVET curriculum, and it is not a drilling course. The CTVET list of approved competency-based programmes that we found does not include borehole drilling, so we wrote this module from public sources. Ask a qualified expert. Drilling must be done by a company holding a Water Resources Commission (WRC) drilling licence. Pump wiring must be done by a certified electrician. This is general information, not legal advice; ask the Water Resources Commission or a qualified lawyer before you act on any licence matter.

Boreholes in Takoradi

The Sekondi-Takoradi Metropolitan Assembly (STMA) says master artisans must register all their trainees. Ground conditions differ from place to place, and we found no Western Region borehole success figure, so always ask a local licensed driller what they find in your area (not verified).

How the module works

Each unit has learning outcomes, performance criteria, the range and the evidence your assessor needs. You are judged Competent or Not Yet Competent by being watched at work, by answering questions, and by your logbook. Every unit ends with a practical task, homework and three "Check yourself" questions.

02

Unit 1 · Work safely at wells, pumps and tanks

A well or a tank can look harmless and still kill. Mains power and water are a dangerous mix. Learn these rules before you touch anything.

Competency standard

Learning outcome Performance criteria — the trainee…
1.1 Wear the right PPE wears boots, gloves, safety glasses and cotton work clothes
1.2 Stay out of confined spaces refuses to enter a well, a tank, a pit or a borehole casing
1.3 Respect electricity treats every pump cable as live; leaves all wiring to a certified electrician
1.4 Lift and carry safely lifts with the legs; uses two or more people for heavy pump parts
1.5 Keep a clean, safe site covers openings; keeps children away; keeps tools tidy

Range. Hand pump sites, pump rigs, tanks and workshop. Evidence. Observation every session; oral questions.

Ask a qualified expert. For electrical, gas, welding, chemical or other dangerous work, use a licensed electrician or a qualified safety officer. In Ghana, indoor and pump wiring belongs to an Energy Commission-certified electrician. Do not attempt work you are not trained and authorised to do. For any injury or illness, see a doctor or nurse. This unit teaches awareness and good practice, not medical treatment.

The big dangers

Danger What can happen The rule
Wells, tanks, pits Bad air or no air; you fall in; people die trying to rescue Never enter. Call a trained rescue team or the fire service on 112
Electricity Shock, burns, death, especially with wet hands or wet ground Switch off at the board; leave wiring to a certified electrician
Open boreholes and well mouths A child or animal falls in; things drop in and pollute Keep every opening capped or covered
Heavy pump parts and pipe Back injury; crushed fingers Lift with your legs; get a second person; use a rope and a stand
Sun, heat and long work Heat illness Drink water; rest in the shade
Chemicals (bleach, fuel, oil) Burns; fumes; poisoning Gloves and glasses; read the label; never mix chemicals

(These are good-practice rules, not Ghana law.)

Never enter a well, tank or casing

A confined space is a place that is small, hard to leave and may hold bad air. People have died in wells and tanks because they went in to help or to clean. Stay outside. Clean tanks from the outside or with trained staff; ask a qualified safety officer for confined-space work.

Electricity and water

  • Water carries electricity. A pump cable that looks fine can still be damaged.
  • Never touch a pump, cable or control box with wet hands, and never plug in or switch on a pump you did not set up with a certified electrician.
  • Pump wiring, earthing and protection are done by an Energy Commission-certified electrician; trainees may only assist with pipe and tank work.
  • Solar pumps have panels that make power in daylight, so the wires can be live even when the pump is off. Leave solar wiring to a licensed installer.

Safe or unsafe?

Your trainer describes eight scenes. For each, say safe or unsafe and why.

Site safety walk

  1. Walk a hand-pump site or the Hub water point with your trainer.
  2. List every opening, cable, tank and chemical you see.
  3. For each, write the danger and the rule from the table.
  4. Check that every borehole opening is capped and the control box is closed.
  5. Put on your PPE and have a partner check it.
  6. Record the walk in your logbook.

Spot the danger

At home or near your house, find three water or electricity dangers (an open well, a loose cable, a leaking tank). Write what you would tell the owner. Do not touch anything.

From the field: When the water gushes into the sky

The moment. Drilling hit a pressurised water table and the water shot high into the air.

The problem. Near overhead high-tension lines, a shock is almost unavoidable. Some drills have gone through buried electric cables, with fatal injuries.

The cause. No one checked the surroundings or the power company before work began.

The lesson. Look up and look down before you drill.

Next time. 1. Watch the surroundings carefully. 2. Contact the power company before any work. 3. Keep clear of lines and cables and have a qualified supervisor on site.

Ask a qualified expert: the power company and a qualified safety officer.

International distance rule (not Ghana law). A common international rule for tall equipment near overhead lines is the United States OSHA table for cranes and derricks: keep at least about 3 m (10 ft) from lines up to 50 kV, about 4.6 m (15 ft) for over 50 to 200 kV, about 6.1 m (20 ft) for over 200 to 350 kV and about 7.6 m (25 ft) for over 350 to 500 kV. A training source says to use 6.1 m (20 ft) if you do not know the voltage. Rain, mist, fog and dust can carry current from a line to a rig mast. You do not know the line voltage, so ask the power company for it and for its own safe distance, and ask a qualified safety officer. Check this against the Energy Commission and power company rules when you read them (not verified for Ghana).

Safety protocol: working at a pump or borehole site

Before you start

  • Walk the site with the owner and note every opening, cable, tank and chemical.
  • Wear boots, gloves, safety glasses and cotton work clothes; check them with a partner.
  • Confirm the pump is switched off and locked out by the electrician before any work near it.
  • Cap or fence every open borehole.
  • Check for overhead lines and tell the trainer if you see any.

While you work

  • Do work in pairs; do keep children and animals away.
  • Do not enter a well, tank or casing.
  • Do not touch cables, control boxes or solar wiring.
  • Do not lift heavy pump parts alone.
  • Drink water and rest in the shade.

After

  • Close and lock the control box and covers (do not open them yourself).
  • Clean and store tools; count them.
  • Report any damage, leak or open borehole to the trainer or owner.

Emergency

  • Call 112 for any serious injury, fire, shock or someone trapped.
  • Switch off the power at the board only if it is safe to reach it; never touch a person who may be in contact with live equipment.
  • Give first aid you were trained to give and keep the person warm and still until help arrives. This is not medical advice.

Tools and items for this unit

Item What it is and its use Size or type Who may handle Also called
PPE: boots, gloves, safety glasses, hard hat and apron Protective gear for the eyes, hands, head and feet. Chemical gloves and glasses are needed for chlorine. Fit and size per person You safety gear; protective clothing
Barrier tape and cones Mark an open borehole or work area so people and children keep away. Visible colour You danger tape; safety cones
First-aid kit Dressings, gloves and washing water. For injuries get a doctor or nurse; call 112 in an emergency. Kept complete You first-aid box
Warning sign and fence A sign and fence around the water point to keep animals and children out. Visible You guard fence; warning board
Lock and tag (lock-out set) A padlock and tag put on the switch so nobody can switch on while work is being done. Electrician rules apply. Per site Electrician padlock and tag; lockout kit

Check yourself

  1. Why must you never go into a well or tank to rescue someone?
  2. Who may wire a pump in Ghana?
  3. Name two things to wear for pump work.
03

Unit 2 · Where borehole water comes from

Borehole water is rain that soaked into the ground years ago. If you understand where it hides, you understand why one borehole is rich and the next one dry.

Competency standard

Learning outcome Performance criteria — the trainee…
2.1 Explain groundwater explains rain, infiltration, aquifer, water table and recharge in plain words
2.2 Name borehole parts names casing, screen, gravel pack, seal, apron and cap
2.3 Explain yield and water level explains yield, static water level and drawdown
2.4 Read a simple borehole record reads depth, water level and yield from a driller's record

Range. Household and small-farm boreholes. Evidence. Labelled sketch; oral questions.

Ask a qualified expert. Where to drill, how deep and how much water you will get are questions for a hydrogeologist or a licensed driller. Do not promise a customer water at a certain depth. Ask the Water Resources Commission or a licensed driller. This is general information, not an engineering design.

How groundwater works

  1. Rain falls and some soaks into the soil. This is infiltration.
  2. The water moves down until it fills the tiny spaces in sand, gravel or cracked rock. A layer of rock or soil that holds and gives water is an aquifer.
  3. The top of the water-filled ground is the water table. It rises in the wet season and falls in the dry season.
  4. Water that soaks in to refill the aquifer is recharge. If people pump out more than recharge brings in, the water table keeps falling.

Pumping too much groundwater can harm the supply, so pumping should follow the water rules.

Why one borehole gives more than the next

Different rocks hold and give water differently. In a study of 2,788 boreholes in the Ashanti Region, boreholes in the Birimian rocks had a drilling success rate of about 91 percent and an average depth of about 53 m, while granitoid rocks had about 72 percent success and mostly low yields. That is another region, so it is an example, not a promise for Takoradi (not verified for Western Region). Water in cracked hard rock is found along cracks, so a borehole a few metres away can be dry.

The borehole and its parts

Part What it does
Casing Plain pipe that keeps the hole open and stops the walls collapsing
Screen Slotted pipe at the water-bearing layer that lets water in and keeps sand out
Gravel pack Clean gravel around the screen that filters the water
Sanitary seal Clay or cement near the top that stops dirty surface water running down the outside
Apron (platform) Concrete slab around the top that carries spilt water away
Cap or pump base Closes the top so nothing falls in

Three words you must know

  • Static water level (SWL): how far down the water stands when nobody is pumping.
  • Drawdown: how much the water level drops while pumping.
  • Yield: how much water the borehole gives, for example in litres per minute or cubic metres per hour (1 cubic metre = 1,000 litres).

The Ashanti study counted 30 to 60 litres per minute as medium yield and over 60 litres per minute as high yield.

Reading a record

A driller's record (example numbers) says: depth 52 m, static water level 14 m, pumped for 6 hours at 3 cubic metres per hour, water level during pumping 21 m. (1) How deep is the water below the ground when nobody pumps? (2) What was the drawdown? (3) How many litres per hour is the yield? (4) How many litres per minute?

Draw and label

  1. Draw a cut-through of a borehole: ground, soil, rock, water table and aquifer.
  2. Add the casing, screen, gravel pack, sanitary seal, apron and cap.
  3. Mark the static water level and draw a second line for the water level while pumping.
  4. Label the drawdown.
  5. Check your drawing with a partner and your trainer.

Ask a neighbour

Ask a household or farm with a borehole: how deep is it, how long ago was it drilled, and does the water drop in the dry season? Write three lines.

From the field: The borehole with no water

The moment. A client paid for a borehole and did not get the water he hoped for.

The problem. The hole was a total loss to the client.

The cause. No proper assessment was made to find the best place for the water.

The lesson. Find the water on paper before you look for it with a drill.

Next time. 1. Look at the land: low-lying places and the water table. 2. Read the geological map of the area. 3. Ask a qualified hydrogeologist before drilling.

Ask a qualified expert: a hydrogeologist or a licensed driller decides where to drill.

From the field: Salt and no water in some rocks

The moment. Near the coast and in some rock types the water comes out salty, or not at all. Yield changes a lot even on one plot.

The cause. Some rocks give salty water or no water. The geological map shows them.

The lesson. Two holes on one plot can give two different answers.

Next time. 1. Check the map before you choose the spot. 2. Test the water for salt before you buy a pump. 3. Do not promise a yield.

Ask a qualified expert: a hydrogeologist, and an accredited laboratory for the salt test.

Ghana groundwater at a glance (read this as a guide, not a promise)

Rock or area What studies say Tag
Birimian rocks (Ashanti Region study) About 90.6 percent of boreholes succeeded; mostly medium to high yield zones Other region, example
Tarkwaian rocks (Ashanti Region study) About 79.5 percent success; mostly medium yield Other region, example
Granitoids (Ashanti Region study) About 72.3 percent success; mostly low yield Other region, example
Western Region, Mpohor Borehole iron 0.17 to 0.58 mg/L Western Region, one study
Coast Salt-water intrusion into coastal aquifers is an emerging issue; the Keta basin is one example Other region, warning
Whole country The most productive aquifers are fractured and weathered zones in several rock groups, and safe yields are poorly known for most aquifers National review

No Takoradi or Western Region yield or success figure was found, so none is printed here. Ask a local licensed driller what they find in your area.

Salt near the coast. Salty groundwater is common close to the shore and a filter cannot take the salt out. Check it with a conductivity meter before a pump is bought. Ask a hydrogeologist or the Water Resources Commission before you promise anyone fresh water.

Parts of a borehole, every part labelled

Parts of a borehole (cut-through) A vertical cut-through of a borehole showing the cap, apron, sanitary seal, casing, gravel pack, screen, sump, water table and the static and pumping water levels. 1Cap or wellhead 2Concrete apron 3Sanitary seal 11Water table 7Gravel pack 10Aquifer (water-bearing layer) 4Casing (plain pipe) 5Static water level 6Pumping level (drawdown) 8Screen (slotted pipe) 9Sump (silt collects)
A borehole cut through. Numbers match the table. The static water level is the water when nobody pumps; the pumping level is lower when the pump runs.
No. Part What it does Safety rule
1 Cap or wellhead Closes the top; carries pipe and cable Keep it on and locked; never stand on it
2 Concrete apron Sheds spilt water into a drain Keep it clean and crack-free; do not store chemicals on it
3 Sanitary seal Stops dirty surface water running down the outside of the casing Never dig it out
4 Casing Keeps the hole open Never enter it
5 Static water level Water depth when nobody pumps Measure only with a dip meter, never by dropping stones or objects
6 Pumping level Water depth when the pump runs; the gap is the drawdown Record it; do not pump a borehole dry
7 Gravel pack Filters the water at the screen Driller only
8 Screen Lets water in, keeps sand out Driller only
9 Sump Silt settles below the screen Driller only
10 Aquifer The water-bearing layer Not to be polluted: keep pollution sources away
11 Water table Top of the water-filled ground It falls in the dry season

A real dip meter

Photograph of a dip meter reel with graduated tape and probeA real water-level tape on a reel with a blue carrying handle and blue frame, the graduated tape wound on the reel, a length of tape hanging free on the right and a steel probe at its end. Five numbered callouts point to these parts.12345
A real dip meter: the tape is wound on the reel and the probe hangs at the end. Numbers match the table. (Photo: CommanderSkylez, CC BY-SA 3.0)
No. Part What it does Safety rule
1 Carrying handle You hold the reel steady with it Stand on firm ground; do not lean over an open casing
2 Reel Stores the tape; you turn it to wind the tape in Wind slowly; keep fingers clear of the reel
3 Graduated tape Printed length marks show the depth to the water Keep it clean; never let it touch a live cable
4 Probe The steel end of the tape that senses the water Lower it slowly; never into a casing with a live pump cable without the electrician's permission
5 Frame Holds the reel upright when you set it down Set it on a clean surface so the tape and probe stay clean

Parts of a dip meter, every part labelled

Parts of a dip meter (water-level tape) A dip meter with its reel and handle, graduated tape, buzzer and light, battery cover and probe, lowered into a casing to the water level with a reference mark at the top of the casing. 1Reel and handle 3Buzzer and light (sounds when the probe is wet) 4Battery cover (keep dry) 2Graduated tape 5Probe (two metal contacts) 6Reference mark (top of casing) 7Water level
A dip meter. The buzzer and light switch on when the probe touches water; read the tape at the reference mark.
No. Part What it does Safety rule
1 Reel and handle Stores and winds the tape Wind slowly; keep fingers clear of the reel
2 Graduated tape Shows the depth in metres Keep it clean; never let it touch a live cable
3 Buzzer and light Show that the probe has touched water Test it in a bucket before use
4 Battery cover Holds the battery Keep it dry and closed
5 Probe Two contacts that sense water Never lower it into a casing that has a live pump cable without the electrician's permission
6 Reference mark The fixed point on the casing you measure from Mark it with paint and record where it is
7 Water level The reading Record the time and whether the pump is on

Safety protocol: using a dip meter

Before you start

  • Ask the owner; confirm with the electrician that the pump is switched off and locked out, or that the casing has a separate access port.
  • Test the buzzer in a bucket.
  • Wear gloves and safety glasses; keep the borehole cap area clear.

While you work

  • Do lower the probe slowly; do read at the same reference mark every time.
  • Do not force the tape if it snags; do not lean over the open casing.
  • Do not touch any cable.

After

  • Wipe, dry and rewind the tape; remove the battery if the meter is stored for a long time.
  • Replace the cap and padlock.
  • Write the reading, time and date in the logbook; report a stuck tape.

Emergency

  • Call 112 for any serious injury, fire, shock or someone trapped.
  • Switch off the power at the board only if it is safe to reach it; never touch a person who may be in contact with live equipment.
  • Give first aid you were trained to give and keep the person warm and still until help arrives. This is not medical advice.

Tools and items for this unit

Item What it is and its use Size or type Who may handle Also called
Dip meter (water-level tape) A reel of graduated tape with a probe that beeps or lights when it touches water. It gives the static and pumping water level from a fixed mark on the casing. Use before and during pumping. Tape 50, 100 or 150 m You (with trainer) water level meter; well sounder; dip tape
Marked bucket (20 L) A bucket with the volume marked on it. Fill it from the spout or pipe and time it to measure flow (bucket test). Use at hand pumps, taps and pump outlets. 20 L; mark the full line with a measured jug You pail; measuring bucket
Stopwatch Times how long the bucket takes to fill. A phone stopwatch is fine. Seconds You timer
Conductivity (EC) or TDS meter Measures dissolved salts as electrical conductivity (uS/cm) or total dissolved solids (mg/L). A quick check for salty water, important near the coast. Use before and during pumping. 0 to 2,000 uS/cm or wider You EC meter; TDS meter; salinity meter
Resistivity set and GPS Instruments used by the hydrogeologist or driller to site a borehole. A trainee only needs the names. n/a Hydrogeologist resistivity meter; survey set
Casing Plain pipe lining the borehole so it does not collapse and so water from above cannot get in. uPVC, steel or HDPE; diameter 100 to 200 mm Driller well casing; lining pipe
Screen (slotted casing) Slotted pipe opposite the water-bearing layer. Water enters through the slots; sand is kept out. Slot size in mm; open area Driller well screen; slotted casing; strainer pipe
Gravel pack (filter pack) Clean, rounded, sized gravel around the screen. It holds back fine sand and keeps the slots open. Grain size in mm; volume Driller filter pack; gravel filter
Sanitary seal (cement or bentonite grout) A sealed collar near the top of the annulus so dirty surface water cannot run down the outside of the casing. Depth and material set by the driller Driller annular seal; grout seal; sanitary grout
Concrete apron, drain and soak-away A concrete slab around the borehole head that sheds spilt water into a drain. Dimensions set by the designer You (assist) platform; pump base; wash slab
Wellhead (well cap and seal plate) The top closure of the borehole. It carries the pipe and cable and keeps dirt and insects out. Fits the casing size Technician well cap; well seal; sanitary cap

Check yourself

  1. What is the water table?
  2. What does the sanitary seal stop?
  3. A borehole's water stands 10 m down and drops to 16 m while pumping. What is the drawdown?
04

Unit 3 · The law and the licensed driller

You do not drill. You help people do it the right way. A trainee who knows the law protects the customer, the water and himself.

Competency standard

Learning outcome Performance criteria — the trainee…
3.1 Know who may drill states that drilling needs a Water Resources Commission licence
3.2 Know the penalties and duties explains the risks of hiring an unlicensed driller
3.3 Describe the drilling job lists the main stages from siting to test pumping
3.4 Know your own limits refuses to drill, and refers customers to licensed drillers

Range. Household and small-farm boreholes. Evidence. Role play; oral questions.

Ask a qualified expert. Drilling is only by licensed drillers. This is general information, not legal advice. Ask the Water Resources Commission (WRC) for the current rules, fees and forms, and ask a qualified lawyer before you act on any licence, permit or registration matter. Do not tell a customer that no permit is needed.

The rules we found

  • Drilling needs a licence. Drilling a well without a WRC drilling licence is an offence under the Drilling Licence and Groundwater Development Regulations, 2006 (L.I. 1827); Regulation 23 sets a fine of up to 200 penalty units or up to 12 months in prison, or both.
  • Enforcement is real. The WRC has fined firms GH¢60,000 and seized their rigs, says people who hire unlicensed drillers may be prosecuted, and says owners must register their boreholes.
  • Constructing boreholes without a licence is illegal, the WRC has said. In 2024 the WRC said it was monitoring for unlicensed drillers.
  • Water use rules are separate. The Water Use Regulations, 2001 (L.I. 1692) set water-use permit categories; a summary says small mechanical abstraction may be exempt from a permit but must still be registered, but the exact threshold was not verified. Ask the WRC.
  • Pollution. A summary says boreholes must not be built so that they let pollution reach the groundwater. The exact rule text was not read; ask the WRC.

Not verified. We could not read the WRC's own application form, the fee, how long a licence lasts, or the exact distance a borehole must keep from a latrine or septic tank. One study warns that a borehole within 30 to 50 m of a septic tank is likely to be polluted. Treat that as a guide, and ask the WRC for the rule.

How a licensed driller works (the main stages)

This is general practice, not a Ghana step list. Your job is to know the stages so you can talk to customers.

  1. Siting. A survey (often an electrical resistivity survey) finds where water is likely.
  2. Drilling. A rig makes the hole. The driller keeps a log of the rock layers.
  3. Casing and screen. Pipe goes in; the screen sits at the water layer.
  4. Gravel pack and seal. Gravel around the screen; a clay or cement seal near the top.
  5. Development. The driller cleans the hole so it gives clear water.
  6. Test pumping. Water is pumped for hours and the levels are recorded to find the safe yield.
  7. Water test and disinfection. A sample goes to a laboratory.
  8. Handover. A record of depth, levels and yield, and the apron and cap are finished.

What you may and may not do

You may You may not
Explain the stages to a customer Drill, or hire out as a driller
Ask a driller for his WRC licence before the customer pays Tell a customer drilling needs no licence
Help the customer keep the driller's record Pump from a borehole the driller has not finished and tested
Refer the customer to the WRC Promise how much water the borehole will give

Spot the problem

A customer says: "A man with a small rig will drill my borehole for half the price. He says he does not need a licence." What do you tell the customer? List three risks.

Role play: the cheap driller

  1. Work in pairs: one is the customer, one is the trainee.
  2. The customer wants the cheapest driller.
  3. The trainee explains the licence rule and what to ask for before work starts.
  4. Swap roles.
  5. Write the three questions you would ask any driller.

Ask the WRC

Find the contact of the WRC office that covers the Western Region (use the WRC website or ask your trainer). Write down how you would ask about a drilling licence. Do not phone for the Hub; your trainer will do that.

From the field: The driller with only a drilling machine

The problem. Most drilling companies skip steps, such as development and testing, because they have only the drilling machine and not the other equipment.

The lesson. A drilled hole is not a finished borehole.

Next time. 1. Ask before hiring what equipment they bring. 2. Insist on development and a pump test. 3. Ask for the completion record.

Ask a qualified expert: the Water Resources Commission and a qualified lawyer for the contract.

What a good driller must do and bring (owner's checklist)

  • Shows a current Water Resources Commission drilling licence
  • Has told the Commission before drilling starts (a summary says a contractor must notify the Commission before constructing a well; read the full text)
  • Keeps a log of the rock layers as the hole goes down and gives you a copy
  • Brings the equipment for the later steps: development tools (bailer, surge block or an airlift), a test pump and a way to measure flow and water level
  • Develops the borehole until the water runs clear, then test pumps, then disinfects
  • Gives you a completion record: depth, casing and screen, gravel pack, seal, water levels, test yield and water test (the RWSN Code of Practice has a suggested format)

Ask a qualified expert. This checklist is general good practice and a summary of the regulations. It is not legal advice. Ask the Water Resources Commission for the current rules and ask a qualified lawyer before signing a drilling contract.

Parts of a drilling rig (names only)

Parts of a drilling rig (names only; trainees never operate it) A truck-mounted drilling rig with a mast, rotary head, drill rods, drill bit, compressor, mud pit and casing, with a danger zone marked. 1Mast (watch for overhead lines) 2Rotary head (turns the rods) 3Drill rods 7Cab and controls (driller only) 5Compressor (air for the hammer) 6Truck chassis and levelling jacks 4Drill bit (hammer bit) 8Mud pit or discharge channel
A drilling rig. You learn the parts so you can talk to drillers. You never operate it and you never stand within its danger zone.
No. Part What it does Safety rule
1 Mast Holds the rotary head and rods upright Keep clear of overhead lines and below the mast when it moves
2 Rotary head Turns the drill rods Never go near moving parts; no loose clothes
3 Drill rods Carry the turning force and air down Keep hands clear when rods are joined
4 Drill bit (hammer bit) Breaks the rock Hot and sharp; driller only
5 Compressor Gives high-pressure air for the hammer Hoses can whip if they fail; stay clear
6 Truck chassis and levelling jacks Carry and steady the rig Do not walk under a raised or jacked load
7 Cab and controls Where the driller works the machine Driller only
8 Mud pit or discharge channel Collects cuttings and water Keep children away; deep mud can trap

Safety protocol: visiting a drilling site (watching only)

Before you start

  • Get the driller's and owner's permission; the trainer comes with you and no more than 8 trainees.
  • Wear boots, hard hat, safety glasses, ear protection and gloves.
  • Ask the driller where the overhead lines and buried cables are, and where to stand.
  • Agree a stop signal and a meeting point.

While you work

  • Do stay outside the marked danger zone and upwind of dust.
  • Do not touch rods, hoses, the hammer or the controls.
  • Do not stand near the hole when the driller blows out cuttings: water can gush up.
  • Do not go near overhead lines or wet cables.

After

  • Wash hands and face; check for cuts.
  • Tell the trainer about any near miss.
  • Write notes in your logbook; never take photos near live hazards unless the driller agrees.

Emergency

  • Call 112 for any injury.
  • If water gushes up near power lines, move away on the driller's signal and stay clear until the power company says it is safe.
  • Do not run into the danger zone to help.

Tools and items for this unit

Item What it is and its use Size or type Who may handle Also called
Drilling rig, compressor, DTH hammer, drill bit, drill rods and mud pump The driller's machine and tools. A down-the-hole (DTH) hammer breaks hard rock with air; a mud pump circulates drilling fluid. You only need the names. Never operate them. Per driller Driller drill rig; drilling machine
Casing Plain pipe lining the borehole so it does not collapse and so water from above cannot get in. uPVC, steel or HDPE; diameter 100 to 200 mm Driller well casing; lining pipe
Screen (slotted casing) Slotted pipe opposite the water-bearing layer. Water enters through the slots; sand is kept out. Slot size in mm; open area Driller well screen; slotted casing; strainer pipe
Sump and centraliser The sump is a plain pipe below the screen where silt settles. Centralisers keep the casing in the middle of the hole. Casing size Driller tail pipe; bottom cap
Gravel pack (filter pack) Clean, rounded, sized gravel around the screen. It holds back fine sand and keeps the slots open. Grain size in mm; volume Driller filter pack; gravel filter
Sanitary seal (cement or bentonite grout) A sealed collar near the top of the annulus so dirty surface water cannot run down the outside of the casing. Depth and material set by the driller Driller annular seal; grout seal; sanitary grout
Bailer and surge block Development tools. A bailer lifts mud out; a surge block moves water in and out of the screen to loosen fines. Per driller Driller sand bailer; mud bucket
Airlift (compressor and eductor pipe) Uses compressed air to lift water and mud from the hole during development. Per driller Driller air-lift development
Test-pumping pump and generator (contractor's) The driller's test pump and its power for the yield test. Check that it can run the full test period. Flow and head to suit the test Driller contractor's test pump

Check yourself

  1. Who may drill a borehole in Ghana?
  2. Can a customer be in trouble for hiring an unlicensed driller?
  3. Name two stages of a drilling job.
05

Unit 4 · Hand pumps and community water points

A hand pump needs no electricity. But a hand pump that nobody looks after soon stops, and a village goes back to dirty water.

Competency standard

Learning outcome Performance criteria — the trainee…
4.1 Name hand pump parts names handle, pump head, rising main, rods, cylinder and plinth
4.2 Do a sanitary inspection checks the apron, drainage, cap and surroundings and records faults
4.3 Do caretaker checks tightens, greases and cleans the water point
4.4 Know who repairs explains the area mechanic and committee roles

Range. Community hand pumps (India Mark II type and similar), with the owner's permission. Evidence. Inspection sheet; oral questions.

Ask a qualified expert. Pulling a hand pump apart and replacing parts in the borehole is for a trained area mechanic. Water from a hand pump that tastes or smells wrong, or that people think made them ill, must be tested at an accredited laboratory: ask the Water Resources Commission and a health worker. Anyone who is ill should see a doctor or nurse. This is general information, not medical advice.

How a deep-well hand pump works

Moving the handle moves a rod up and down inside the rising main. At the bottom, a cylinder with a valve (a one-way door) lifts a little water on each stroke. The India Mark II is designed to lift water from deep wells up to about 50 m. Ghana's CWSA guidelines list four standard hand pumps: Nira, Afridev, the Ghana-modified India Mark II and the French Vergnet.

Who looks after it

Under the community-based model, a water and sanitation team signs a contract with an area mechanic for regular maintenance, and the mechanic is paid from water sales; each pump should have two trained caretakers, a man and a woman. Those guidelines are from 2010 and may have changed; ask your local CWSA or Assembly office (not verified for today).

Reality check. One monitoring summary found that half of the community management team members said it takes more than three days to get a mechanic. A trained local helper who can do the simple jobs fast keeps the village supplied.

Caretaker checks (daily, weekly, monthly)

How often Check
Every day Look for leaks; spout and apron clean; no animals; cap and cover in place
Every week Handle bolts tight; drainage channel clear; no standing water near the pump
Every month Pump head and handle bearings greased as the maker says; fix small cracks in the apron; tell the mechanic about heavy or stiff handles

(Good practice, from pump makers' manuals in general; follow your own pump's manual.)

Sanitary inspection

Walk around the water point and look for anything that can bring dirt to the water: a cracked apron, standing water, a latrine or rubbish pit near the pump, an uncovered opening, animals, a broken drain. Record each fault as yes or no and give the list to the committee.

Hand pump check

  1. Visit a hand pump with the committee's permission.
  2. Do the daily and weekly checks from the table. Time how long it takes to fill a 20-litre bucket and count the strokes.
  3. Do the sanitary inspection and write down every fault.
  4. Tighten loose handle bolts with the right spanner (do not open the pump).
  5. Fill in the inspection sheet and give a copy to the caretaker.
  6. Record it in your logbook.

Who is the mechanic?

Find out who the caretaker or area mechanic is for one hand pump near you. Ask how long the last repair took and what it cost. Write down the answer and the date.

From the field: The seal that always goes

The problem. On hand pumps the rubber seals fail most often.

The lesson. Keep spare seals before the pump stops.

Next time. 1. Keep a seal kit with the community. 2. Learn the replacement steps. 3. Check the seals at every visit.

Ask a qualified expert: the area mechanic does the replacement.

Hand pump parts card (Afridev and India Mark II type)

Part (top to bottom) What it does Common fault
Handle and pump head Turns your hand movement into rod movement Loose bolts; worn bearings
Rising main Carries the water up Corroded steel pipe or cracked plastic pipe
Pump rods and couplings Carry the movement down to the plunger Loose or broken couplings
Cylinder and plunger Lift the water at each stroke Worn cup seal or U seal
Foot valve Holds the water in the cylinder Dirt under the valve

A study that took apart 145 handpump boreholes in three African countries found the rising mains in poor condition, with 53 percent of galvanised pipes corroded and 82 percent of uPVC pipes damaged. The standard Afridev manual has a replacement-interval table for wearing parts.

Seals. Keep a set of seals in the spares kit. A caretaker does not replace seals inside the borehole: that is the area mechanic's job, using the maker's manual.

A real hand pump

Photograph of a deep-well hand pumpA real hand pump standing on a concrete apron in dry ground: a long handle on the left, a boxy pump head, a spout on the right, a steel column, a round base plate and the concrete apron around it. Six numbered callouts point to these parts.123456
A real deep-well hand pump of the India Mark II type, standing on its concrete apron. Numbers match the table. (Photo: Greg Carlson, CC0)
No. Part What it does Safety rule
1 Handle You move it up and down to work the pump Keep fingers clear of the pivot; do not hang on it or let children swing on it
2 Pump head Holds the pivot and joins the handle to the rods below Report loose bolts or cracks to the area mechanic
3 Spout The water comes out here Keep the place under it clean; do not let dirty containers touch it
4 Column Holds the head above the borehole and covers the pipe and rod inside Do not unbolt it; opening it is the mechanic's job
5 Base plate Sits on top of the borehole and keeps dirt out Report a loose or cracked plate; never leave the borehole open
6 Concrete apron A slab with a raised rim around the pump that keeps spilt water off the borehole Keep it clean and the drain clear; report cracks

Parts of a hand pump, every part labelled

Parts of a deep-well hand pump A hand pump with its handle, fulcrum, pump head, spout, plinth, rising main, pump rod, cylinder, plunger with cup seal, foot valve and casing. 1Handle 2Fulcrum (pivot) 3Pump head 4Spout 5Plinth and apron (concrete) 6Rising main 7Pump rod (inside the rising main) 11Casing 8Cylinder 9Plunger with cup seal 10Foot valve
A deep-well hand pump (Afridev and India Mark II type). The handle moves the rod up and down; the plunger and cup seal in the cylinder lift the water.
No. Part What it does Safety rule
1 Handle Your hand movement Keep fingers clear of the pivot; do not hang on it
2 Fulcrum (pivot) Lets the handle swing Grease as the maker says; keep bolts tight
3 Pump head Holds the handle and joins the rod to the main Do not open; area mechanic only
4 Spout Delivers the water Keep the apron clean
5 Plinth and apron Concrete base that sheds spilt water Repair cracks; keep the drain clear
6 Rising main Carries the water up Mechanic only to pull
7 Pump rod Moves the plunger Do not pull; it can drop and injure
8 Cylinder Where the water is lifted Mechanic only
9 Plunger with cup seal Seals and lifts; the seal wears first Mechanic only; spare kit kept
10 Foot valve Holds the water in the cylinder Mechanic only
11 Casing Lines the borehole Never enter

Safety protocol: hand pump caretaker checks

Before you start

  • Wear gloves and boots; tell the committee you are checking.
  • Bring the right spanner, grease, a clean bucket and a stopwatch.
  • Look for children or animals near the pump.

While you work

  • Do tighten loose handle bolts; do clear the drain; do grease as the maker says.
  • Do not open the pump head or pull rods or pipes.
  • Do not use the pump handle for hanging or lifting.

After

  • Wipe the pump and apron; store tools.
  • Record faults and the bucket-test time in the logbook.
  • Tell the area mechanic the same day about a stiff handle, low flow or loose parts.

Emergency

  • Call 112 for any serious injury, fire, shock or someone trapped.
  • Switch off the power at the board only if it is safe to reach it; never touch a person who may be in contact with live equipment.
  • Give first aid you were trained to give and keep the person warm and still until help arrives. This is not medical advice.

Tools and items for this unit

Item What it is and its use Size or type Who may handle Also called
Hand pump (Afridev, India Mark II, Nira, Vergnet) A pump worked by arm or foot with no electricity. Afridev and India Mark II lift water with a handle, rods and a cylinder in the borehole; Nira and Vergnet are other designs on the CWSA list. India Mark II lifts to about 50 m Area mechanic village pump; community pump
Pump head, handle and fulcrum The part above ground that you move. The handle turns the hand movement into up and down rod movement. Per pump model Caretaker pump head assembly
Pump rod and rod coupling Rods inside the rising main that carry the up and down movement to the plunger. Couplings join rods. Stainless steel or fibreglass; per metre Area mechanic sucker rod; lift rod
Cylinder and plunger (piston) The cylinder sits in the water. The plunger moves inside it and lifts water on each stroke. Per pump model Area mechanic pump cylinder; working barrel
Cup seal (piston seal) and U seal Rubber lips that seal the plunger against the cylinder wall. They wear first and are the most frequent repair on community hand pumps. Per pump model; use maker parts Area mechanic piston seal; bucket seal; U-seal
Bobbin and rod centraliser Plastic guides that keep the pump rod in the middle of the rising main so it does not rub. Per pump model Area mechanic rod guide; centraliser
Spares kit (seals, rod couplings, bobbins and bolts) A box of the parts that wear most, kept by the committee so repairs are quick. Per pump model Committee and mechanic seal kit; repair kit
Marked bucket (20 L) A bucket with the volume marked on it. Fill it from the spout or pipe and time it to measure flow (bucket test). Use at hand pumps, taps and pump outlets. 20 L; mark the full line with a measured jug You pail; measuring bucket
Stopwatch Times how long the bucket takes to fill. A phone stopwatch is fine. Seconds You timer
Hacksaw, pipe wrench, spanners and vice The plumber's hand tools: cut pipe, grip and turn pipe, tighten bolts, hold work. Pipe wrench 14 to 24 inch You pipe saw
Screwdrivers, hammer and pliers Basic hand tools for the hand pump and tank. Standard sizes You hand tools

Check yourself

  1. What does the rising main carry?
  2. Name two things you look for in a sanitary inspection.
  3. Who signs a contract with the area mechanic under the CWSA model?
06

Unit 5 · Electric and solar submersible pumps

A submersible pump works at the bottom of the borehole, out of sight. You must know what is down there, what the electrician does and what you do.

Competency standard

Learning outcome Performance criteria — the trainee…
5.1 Name the parts of a pump system names pump, motor, rising main, cable, control box, float, tank and valves
5.2 Choose between pump types explains hand, submersible, surface and solar pumps and when each fits
5.3 Assist with the pipework pipes a pump to a tank with isolation and check valves
5.4 Know the licences states who may wire, who may install a solar pump

Range. Household and small-farm systems. Evidence. Pump-and-tank rig; oral questions.

Ask a qualified expert. Pump wiring is for an Energy Commission-certified electrician, and a solar water pump must be installed by a licensed solar pump installer. Do not connect power, open the control box or touch solar wiring. For pipes and fittings, see Basic Plumbing in this library. This is general information, not legal advice.

The parts of a submersible system

  • Pump and motor hang in the water inside the casing, below the lowest water level.
  • Rising main (drop pipe) carries water up.
  • Cable brings power down and must be rated for use in water.
  • Control box or switch starts and protects the motor.
  • Float switch in the tank stops the pump when the tank is full.
  • Check valve and isolation valves stop water running back and let you cut off the pump for repair.
  • Tank stores water so the pump does not run all day.

Which pump?

Type Where it sits Good for Watch out
Hand pump On top of the borehole Villages, no power Slow; needs a caretaker
Submersible Inside the borehole, under water Deep boreholes; homes and farms Wiring and pulling it up need skilled people
Surface pump At the surface, next to the tank Shallow water or tanks Cannot lift from deep boreholes
Solar pump Panels at the surface; pump in or beside the borehole Farms and places without grid power Needs a licensed installer; sized to the sun

Do not buy a pump by price alone. Many cheap listings are sewage or garden pumps, and the pump must fit the borehole and the job.

The solar pump and the tank

A solar pump system has panels, a mounting, a pump controller, a surface or submersible pump, and pipes or a storage tank. Pumping water up to a raised tank is a cheaper way to store energy than batteries. In Ghana, a solar water pump installer needs an Energy Commission licence for solar pump service providers, a CEWP certificate for the solar side and an NVTI Grade 1 plumbing certificate for the pump side.

Pump-and-tank pipework (what you may do)

  • Put the pump on a tank, not directly on the mains. Basic Plumbing in this library explains why connecting a pump to the mains is an illegal connection.
  • Fit an isolation valve on each side of the pump, a check valve after it, and a float or automatic control. The electrician wires the control.
  • Prices are examples: in Greater Accra listings in October 2026, a 1 HP submersible pump was about GH¢1,095 and a DC solar 1 HP surface pump was about GH¢6,500. These are classified-ad prices, not a market survey.

How long to fill?

Example: a pump gives 1,500 litres per hour (1.5 cubic metres per hour). (1) How long to fill a 1,000-litre tank from empty? (2) How long to fill a 3,000-litre tank? (3) A 1,000-litre tank was listed at about GH¢1,815. How much would three tanks cost?

Pump-and-tank rig

  1. Study a submersible pump (cut-away or spare) and name its parts.
  2. Pipe a small pump to a tank on the rig: isolation valve, pump, check valve, tank inlet, float, overflow.
  3. The certified electrician connects power. Stay clear of the control box.
  4. Fill the tank and write down the time; compare with the exercise.
  5. Check every joint for leaks, then record the work in your logbook.

Price check

Visit or phone two pump shops. Write down the price of a 1 HP submersible pump and a 1,000-litre tank, with the shop name and date.

From the field: The rating that was not true

The problem. Many pumps have a capacity written on them far above what they deliver, and give up after a few days.

The lesson. Do not trust the number on the box.

Next time. 1. Compare with the pump curve. 2. Test the flow with a bucket and a timer. 3. Keep the receipt and ask for a guarantee.

Ask a qualified expert: the pump supplier or a GhIE-registered engineer.

Bucket test for a pump outlet

  1. Fill the marked bucket from the pump outlet and start the stopwatch at the first drop.
  2. Stop the stopwatch when the bucket is full to the mark.
  3. Flow in litres per minute = 1,200 divided by the seconds taken (for a 20 L bucket).
  4. Flow in cubic metres per hour = 72 divided by the seconds taken.
  5. Example: 40 seconds gives 1,200 ÷ 40 = 30 L/min, which is 72 ÷ 40 = 1.8 m3/h.

Ask a qualified expert. Pump wiring, earthing and protection are for an Energy Commission-certified electrician, and solar wiring for a licensed solar installer. Do not open a control box. This is general information, not electrical advice.

A real submersible pump

Photograph of a submersible pump with its power cableA real submersible pump lying on a floor: a long stainless steel body, a perforated intake band near the upper end, a blue power cable and a threaded steel pipe stub at the lower end. Four numbered callouts point to these parts.1234
A real submersible pump lying on a floor before installation. Numbers match the table. (Photo: Mar11, CC BY-SA 4.0)
No. Part What it does Safety rule
1 Power cable Carries electricity to the motor Never lift or carry the pump by its cable; the electrician makes every cable connection
2 Intake strainer (perforated band) Water enters through the small holes; they keep out large grit A pump set too deep in silt can block it; tell the driller if sand comes out
3 Steel body The watertight casing around the working parts Do not open it; never run the pump out of water
4 Threaded pipe end A steel pipe fitting at one end of the pump, where the pipe joins The installer makes this joint; ask the installer to check a badly rusted fitting

Parts of a submersible pump system, every part labelled

A submersible pump system, parts in place A casing with a submersible pump and motor, a rising main, drop cable, wellhead, check valve, isolation valve, control box, raised tank with float switch and overflow. 1Wellhead cap 2Casing 3Rising main 4Drop cable (dashed) 5Pump end 6Motor 7Check valve 8Isolation valve 9Control box 10Tank 11Float switch 12Overflow pipe
A submersible pump system. Numbers match the table. The dashed line is the drop cable; the electrician connects the control box.
No. Part What it does Safety rule
1 Wellhead cap Closes the casing; holds pipe and cable Keep locked
2 Casing Lines the borehole Never enter
3 Rising main Carries water up Pull only with trained people
4 Drop cable Brings power to the motor Treat as live; never touch or cut
5 Pump end Lifts the water Never touch when powered
6 Motor Drives the pump end Never touch when powered
7 Check valve Stops water running back Fit the arrow in the flow direction
8 Isolation valve Lets you cut off water for repair Close slowly
9 Control box Starts and protects the pump Closed and locked; electrician only
10 Tank Stores water Never enter
11 Float switch Stops the pump when the tank is full Electrician wires it; you only check the float moves freely
12 Overflow pipe Carries away extra water Keep it clear

Safety protocol: working on a pump and tank (pipework only)

Before you start

  • The electrician switches off, locks out and tests the circuit dead before you start; you see the lock.
  • Wear gloves, glasses and boots; keep your hands dry.
  • Check the isolation valve is closed and the tank base is level and strong.

While you work

  • Do join pipes with the right fittings and PTFE tape; do check every joint for leaks.
  • Do not open the control box or touch cables, even a damaged one.
  • Do not switch the pump on yourself; do not run it dry.

After

  • Clean up spilt water; remove tools.
  • Tell the electrician when the pipework is finished; the electrician removes the lock.
  • Write the work in your logbook.

Emergency

  • Call 112 for any serious injury, fire, shock or someone trapped.
  • Switch off the power at the board only if it is safe to reach it; never touch a person who may be in contact with live equipment.
  • Give first aid you were trained to give and keep the person warm and still until help arrives. This is not medical advice.

Hand tools protocol

Safety protocol: hacksaw, pipe wrench and spanner use

Before you start

  • Check the tool is the right size and in good condition; cracked handles are thrown away.
  • Clamp the pipe in a vice or have a partner hold it; wear gloves and glasses.

While you work

  • Do pull the wrench towards you; do cut away from your body.
  • Do not use a pipe as an extension on a wrench; do not use a spanner as a hammer.

After

  • Deburr cut edges; clean and store tools; count them.
  • Report any damaged tool.

Emergency

  • Cuts: press with a clean cloth and get a nurse or doctor. Call 112 for a severe injury.

Tools and items for this unit

Item What it is and its use Size or type Who may handle Also called
Submersible pump Pump and motor in one unit hung under the water. The pump end lifts the water and the motor drives it. Use for deep boreholes. Diameter 3, 4 or 6 inch; kW; single or three phase Electrician and technician submersible borehole pump; deep-well pump
Control box or starter (DOL, star-delta) Switches and protects the motor. Opening it is electrician-only work. kW; phase Electrician starter; motor starter; control panel
Breaker (MCB), RCD and fuse Switch off on overload or earth fault. The RCD protects people from shock. Amps; RCD mA set by the electrician Electrician circuit breaker; MCB; trip switch
Float switch (tank) A float that rises with the water and stops or starts the pump at set levels. Type to suit the control Electrician and you float control; tank level switch
Drop cable (submersible cable) Waterproof cable from the control box down to the motor. mm2; cores; length Electrician submersible cable; flat pump cable
Rising main (drop pipe) The pipe that carries water from the pump up to the surface. uPVC, HDPE or galvanised steel; size; pressure class PN Technician drop pipe; riser pipe; column pipe
Check valve (non-return valve) Lets water flow one way only so the pipe does not drain and the pump does not spin backwards. Same size as the pipe; spring or swing Technician non-return valve (NRV); one-way valve
Isolation valve (gate or ball valve) Opens or shuts the flow so one part can be cut off for repair. Pipe size; PN You stop valve; shut-off valve
Tank, stand, overflow, vent screen and manhole cover Tank stores water; stand lifts it for pressure; overflow carries surplus away; vent screen keeps insects out; manhole cover is the lockable lid. Litres; plastic or concrete You (assist) storage tank; reservoir
Solar pump and controller A pump driven by solar panels. The controller (with MPPT) converts and protects. Array kWp; voltage; flow and head Licensed installer solar borehole pump; PV pump
Solar panel (PV module) and array A panel makes DC power in daylight. An array is panels joined together. Wires can be live even when the pump is off. Wp per panel; number Licensed installer solar panel; PV panel
PTFE tape, jointing compound and solvent cement PTFE tape seals threaded joints; jointing compound seals larger threads; solvent cement welds uPVC pipe joints. Per product label You thread seal tape; plumber's tape
Marked bucket (20 L) A bucket with the volume marked on it. Fill it from the spout or pipe and time it to measure flow (bucket test). Use at hand pumps, taps and pump outlets. 20 L; mark the full line with a measured jug You pail; measuring bucket
Stopwatch Times how long the bucket takes to fill. A phone stopwatch is fine. Seconds You timer

Check yourself

  1. What does a check valve do?
  2. Who connects the power to a pump?
  3. Why is a raised tank useful with a solar pump?
07

Unit 6 · Storage, water quality and tests

Clear water is not always safe water. Germs and metals cannot be seen. The only way to know is to test.

Competency standard

Learning outcome Performance criteria — the trainee…
6.1 Keep stored water safe keeps tanks closed, clean and covered
6.2 Know common problems names iron, germs and turbidity and the signs of each
6.3 Take a water sample fills a clean sample bottle the right way
6.4 Clean and sanitise a small tank uses the bleach dose with the trainer

Range. Household and small-farm water. Evidence. Sample record; tank cleaning record; oral questions.

Ask a qualified expert. Water quality advice needs an expert. Ask the Water Resources Commission and test your water at an accredited laboratory before anyone drinks it. Treat the results as the expert's, not yours. Bleach is a chemical: wear gloves and glasses, never mix it with another cleaner, and keep children away. Anyone who is ill should see a doctor or nurse. This is general information, not medical advice.

What can be wrong with borehole water

  • Iron and manganese make water taste of metal and leave brown or black stains. In a study of Mpohor in the Western Region, borehole iron ranged from 0.17 to 0.58 mg/L and manganese from 0.03 to 0.14 mg/L. The draft Ghana Standard asks for iron not above 0.3 mg/L. That standard was a public review draft, so check the final one, and note that sources differ on the iron limit (not verified).
  • Germs. The draft standard asks for no E. coli or total coliform in 100 ml of drinking water. You cannot see germs. Only a laboratory test shows them.
  • Muddy water (turbidity). The draft standard asks for turbidity not above 5 units and pH between 6.5 and 8.5.
  • Some Ghana groundwater has iron or fluoride that need treatment, so test borehole water before drinking. An accredited Ghana Standards Authority laboratory is the place for a drinking-water test.

An example price: a water-quality test was estimated at GH¢300 to 800 in a 2026 article. This is a blog estimate; ask the laboratory.

Taking a sample

  1. Ask the laboratory for their own sterile bottle and their rules.
  2. Wash your hands; do not touch the inside of the cap or bottle.
  3. Run the tap or pump for a few minutes first.
  4. Fill the bottle, close it, label it (place, date, time, your name).
  5. Keep it cool and take it to the laboratory the same day, as the laboratory instructs.

Tank care and sanitising

  • Keep tank lids closed and locked, and clean out dirt before you dose.
  • To sanitise a household tank, use about 1 to 1.5 fluid ounces (2 to 3 tablespoons) of plain household bleach (5.25%) for every 500 US gallons, stir, close the tank and wait at least 8 hours; do not drink until the smell has gone. Convert the tank size from litres first (1 US gallon is about 3.8 litres).
  • Do not enter the tank. Clean from outside or with trained staff.

Check the bleach. Bleach strengths differ by brand. Read the label; if it is not 5%, ask your trainer to help you adjust the dose.

Bleach dose

Example: a 2,000-litre tank. (1) How many US gallons is that (use 3.8 litres per gallon)? (2) The dose is 1 to 1.5 fluid ounces per 500 gallons. What is the dose range for this tank?

Sample and clean

  1. Practise taking a sample with a clean bottle from the Hub tap. Label it. (Your trainer decides whether to send it to a laboratory.)
  2. With the trainer, clean and sanitise a small tank from outside: remove dirt, calculate the dose, dose, close and wait.
  3. Put a clear notice on the tank: "Not for drinking until the smell has gone".
  4. Write the date, tank size, bleach strength and dose in your logbook.

Laboratory price

Phone or visit an accredited laboratory in Takoradi or Accra. Ask what a drinking-water test costs and how to bring the sample. Write the answer with the date.

Salt is common in borehole water near the coast. Ask for a salt (conductivity) check as well as the germ test.

Water test card

What to check Limit or guide Who checks Source and tag
E. coli and total coliform None in 100 mL Accredited laboratory Draft Ghana Standard; WHO guidelines also say none
Iron Not above 0.3 mg/L Laboratory or iron test kit Draft Ghana Standard, final text not read
Turbidity Not above 5 NTU Laboratory or turbidity tube Draft Ghana Standard
pH 6.5 to 8.5 pH strip or meter Draft Ghana Standard
Salt (conductivity) Fresh water has low conductivity; ask the laboratory for the limit Conductivity meter Not verified for Ghana

Sample bottle rules. Use the laboratory's own bottle; do not touch the inside of the cap or bottle; label place, date and time; keep cool; deliver the same day if the laboratory says so.

Tank cleaning card

  • Wear gloves and glasses; never enter the tank
  • Scrub and rinse from outside or have trained staff do it
  • Dose with bleach as in this unit; calculate from the tank volume and the bleach strength on the label
  • Close the lid, wait the time (at least 8 hours), then flush
  • Put a notice "Not for drinking until the smell has gone"
  • Write date, tank size, strength and dose in the logbook

Safety protocol: mixing bleach (chlorine) and cleaning a tank from outside

Before you start

  • Read the label; know the strength (percent).
  • Wear gloves, glasses, an apron and boots; work in open air.
  • Have clean water ready to wash your skin or eyes.
  • Never mix bleach with another cleaner, acid or fuel.

While you work

  • Do measure with a jug, add bleach to water, not water to bleach, and stir with a clean stick.
  • Do not breathe the fumes or enter the tank.
  • Do not leave bleach where children can reach it.

After

  • Close the tank; put the notice on it; wash tools and your hands.
  • Store the bleach cool, closed and labelled.
  • Write the date, tank size, strength and dose in the logbook.

Emergency

  • Bleach in the eyes: rinse with clean water for 15 minutes and get a nurse or doctor (first aid, not medical advice). Swallowed: do not make the person vomit; call 112.
  • Strong fumes: move to fresh air.

Tools and items for this unit

Item What it is and its use Size or type Who may handle Also called
Sample bottles Sterile bottles from the laboratory for germ tests and clean bottles for chemistry. The laboratory tells you which and how to keep the sample. 250 or 500 mL You sample container; sample jar
Clean hose, bucket and jug for sampling Clean tools for taking a sample without touching the inside of the bottle. Clean and rinsed You sampling hose
pH meter or pH strip Shows how acid or alkaline the water is, on a scale of 0 to 14. Use on a fresh sample. 0 to 14 You pH tester; pH strip
Test strips and colour comparator Small paper strips or colour charts for quick checks on pH, chlorine and hardness. Per product You test paper; colour chart
Conductivity (EC) or TDS meter Measures dissolved salts as electrical conductivity (uS/cm) or total dissolved solids (mg/L). A quick check for salty water, important near the coast. Use before and during pumping. 0 to 2,000 uS/cm or wider You EC meter; TDS meter; salinity meter
Chlorine (HTH granules or liquid bleach) The disinfectant. HTH is strong granular calcium hypochlorite (strength on the label); household bleach is weaker (often 3.5 to 5 percent: read the label). Strength on the label You (with trainer) calcium hypochlorite; sodium hypochlorite (bleach)
Measuring jug and clean bucket Measure and mix the dose of chlorine. 1 L jug; 10 to 20 L bucket You measuring cup
PPE: boots, gloves, safety glasses, hard hat and apron Protective gear for the eyes, hands, head and feet. Chemical gloves and glasses are needed for chlorine. Fit and size per person You safety gear; protective clothing
Tank, stand, overflow, vent screen and manhole cover Tank stores water; stand lifts it for pressure; overflow carries surplus away; vent screen keeps insects out; manhole cover is the lockable lid. Litres; plastic or concrete You (assist) storage tank; reservoir

Check yourself

  1. Can you tell by looking that water is safe to drink?
  2. Where should a drinking-water test be done?
  3. Why must you never enter a tank to clean it?
08

Unit 7 · Your location, business ideas and marketing yourself

You can earn without drilling a single hole. Water needs care, checking, cleaning and repair, in every town.

Competency standard

Learning outcome Performance criteria — the trainee…
7.1 Choose a good location picks where customers have boreholes, tanks and pumps and few helpers
7.2 List business ideas names three lawful services he or she can offer
7.3 Do simple money maths works out cost, price and profit for a month
7.4 Market yourself sets up WhatsApp Business and asks for referrals

Range. One small service business. Evidence. Costing sheet; one-page plan; oral questions.

Ask a qualified expert. Business registration, tax and loans need an expert. This is general information, not legal or financial advice. Check with the Sekondi-Takoradi Metropolitan Assembly, the Ghana Revenue Authority (GRA) or a qualified accountant before you register or borrow. Never advertise drilling, wiring or solar installation unless you hold the licence.

Where there is work

  • Homes, schools, clinics, churches and farms with a borehole and a tank.
  • Places far from town where a mechanic takes days to come: a trained local helper is valuable.
  • Near suppliers and shops, so you can buy fittings fast.

Business ideas you may lawfully offer

Service Notes
Hand pump caretaker or helper to the area mechanic Under the committee or mechanic; no drilling
Pump-and-tank pipework helper With a licensed plumber or contractor; electrician does wiring
Tank cleaning from outside, water sampling runs Never enter a tank; use the laboratory
Water point inspection reports for farms and schools Sanitary inspection sheet
Selling fittings and spares Shop or mobile

Stay inside the law: no drilling without a WRC licence, no wiring without certification and no solar pump installation without the Energy Commission licences.

Money maths (all numbers are examples)

One month as a hand-pump and tank helper

You do 4 service jobs in a month. Each job: you charge GH¢150; parts and grease cost GH¢40; transport costs GH¢20. (1) Total income? (2) Total costs? (3) Profit? (4) Profit as a share of income, as a percentage?

Marketing yourself

  • Set up WhatsApp Business with your name, services and area.
  • Ask every happy customer for a referral and a photo of the finished job (with permission).
  • Keep a simple portfolio: photo, date, what you did.
  • Put a Google Business Profile in your name when you have steady customers.
  • Never promise what you may not do: no "borehole drilling" if you are not licensed.

Registering

A sole proprietor business name was GH¢130 to register at the Office of the Registrar of Companies in 2026, with GH¢70 a year to renew. Assembly operating permits are applied for through the Assembly; fees are in the STMA fee-fixing resolution. Ask STMA which permit applies to you (not verified).

Accessibility

Persons with disabilities can do many tasks in this field. Under the Persons with Disability Act 2006, you have the right to training and work. Workable tasks: written sanitary-inspection sheets, record keeping, water-sampling runs, shop and parts sales, WhatsApp marketing, customer visits, tank-level logs. Helpful changes: a helper for heavy lifting, a stool at the bench, large-print or voice-note checklists, and clear step cards for deaf trainees. Ask the Assembly or the Department of Social Welfare about support.

Your one-page plan

  1. Choose one service from the table.
  2. Write the area you will serve and ten possible customers.
  3. List your tools and parts and what they cost (example prices are fine).
  4. Work out a price for one job.
  5. Write a WhatsApp Business message to introduce yourself.
  6. Show your plan to your trainer.

Three customers

Ask three people with a tank, pump or hand pump what problem costs them most. Write their answers and what you could offer.

Tools and items for this unit

Item What it is and its use Size or type Who may handle Also called
Hacksaw, pipe wrench, spanners and vice The plumber's hand tools: cut pipe, grip and turn pipe, tighten bolts, hold work. Pipe wrench 14 to 24 inch You pipe saw
Screwdrivers, hammer and pliers Basic hand tools for the hand pump and tank. Standard sizes You hand tools
PTFE tape, jointing compound and solvent cement PTFE tape seals threaded joints; jointing compound seals larger threads; solvent cement welds uPVC pipe joints. Per product label You thread seal tape; plumber's tape
Spares kit (seals, rod couplings, bobbins and bolts) A box of the parts that wear most, kept by the committee so repairs are quick. Per pump model Committee and mechanic seal kit; repair kit
Marked bucket (20 L) A bucket with the volume marked on it. Fill it from the spout or pipe and time it to measure flow (bucket test). Use at hand pumps, taps and pump outlets. 20 L; mark the full line with a measured jug You pail; measuring bucket
Stopwatch Times how long the bucket takes to fill. A phone stopwatch is fine. Seconds You timer
Sample bottles Sterile bottles from the laboratory for germ tests and clean bottles for chemistry. The laboratory tells you which and how to keep the sample. 250 or 500 mL You sample container; sample jar

Check yourself

  1. Name two services you may offer without a drilling licence.
  2. Why must you never advertise drilling?
  3. A job earns GH¢200 and costs GH¢80. What is the profit?
09

Glossary

Term Meaning
Aquifer Rock or soil layer that holds and gives water
Apron Concrete slab around a borehole or hand pump
Area mechanic Trained person paid to look after hand pumps
Casing Plain pipe that keeps a borehole open
Competent / Not Yet Competent The two possible results of a CBT assessment
Drawdown How far the water level drops when pumping
Gravel pack Clean gravel around the screen
Recharge Rain water that refills the aquifer
Rising main The pipe that carries water up
Sanitary seal Clay or cement that stops dirty water running down the hole
Static water level Water depth when nobody is pumping
Yield How much water a borehole gives
10

Logbook

Copy these pages into an exercise book. Your logbook is part of your assessment evidence.

  • Unit 1: site safety walk; dangers list
  • Unit 2: labelled borehole drawing; record reading
  • Unit 3: role play notes; questions for a driller
  • Unit 4: hand pump checks; sanitary inspection sheet; bucket test
  • Unit 5: pump parts list; rig record; price check
  • Unit 6: sample record; tank cleaning record; laboratory price
  • Unit 7: costing sheet; one-page plan; customers list
  • Every homework, dated
11

Self-check quiz

  1. Why must you never enter a well or tank?
  2. Who may wire a pump in Ghana?
  3. What is the water table?
  4. What does the sanitary seal stop?
  5. What is drawdown?
  6. Who may drill a borehole?
  7. What can happen to a person who hires an unlicensed driller?
  8. Name two checks a hand pump caretaker does.
  9. Which pipe carries water up from a submersible pump?
  10. Why is a float switch fitted in the tank?
  11. Why test borehole water at an accredited laboratory?
  12. Name two services you may offer without a drilling licence.
12

Appendix A · Bench card pack

One page each. Print them and keep them in your toolbox. Numbers marked international come from foreign standards and must be checked against the Ghana text when you read it.

Ask a qualified expert. These cards give good practice for electrical, chemical, pressure and lifting hazards. They are not a substitute for a certified electrician, a licensed driller or a qualified safety officer. Water quality advice must come from an accredited laboratory and the Water Resources Commission. This is general information, not legal or medical advice.

Card 1 · Safety

Hazard Rule
Well, tank, pit, casing Never enter. Call trained rescue or 112
Electricity Switch off, lock out, and leave wiring to the certified electrician. Water carries current
Overhead lines Ask the power company before work; keep the distance in the Unit 1 box (international rule)
Buried cables Ask the power company and utilities before any digging or drilling
Pressurised water A drill can hit water that shoots up high. Stand clear and follow the driller's stop signal
Lifting Two people for heavy pump parts; never lift with your back
Chemicals Gloves and glasses; never mix chemicals
Open holes Cap or cover every borehole opening

Card 2 · Parts of a borehole and pump (what you see)

Part Where Tag
Borehole cap or wellhead On top of the casing Do not remove
Apron Concrete around the head Check for cracks
Rising main Pipe from the pump up Technician only
Drop cable and control box Wire down; box on the wall Do not touch; electrician only
Float and tank Float in the tank stops the pump You may check from outside
Hand pump head, handle Above the borehole Caretaker greases and tightens

Card 3 · Law (who does what)

Rule Who What it means for you
Drilling licence (L.I. 1827) Water Resources Commission; the drilling company Drilling without a licence is an offence; ask for the licence
Register your borehole Owner The WRC says owners must register boreholes
Water use rules (L.I. 1692) WRC Permit categories; exact exemption threshold not verified
Wiring and solar pumps Energy Commission-certified electrician; licensed solar installer You assist; you do not connect

Card 4 · Hand pump caretaker (daily, weekly, monthly)

See the table in Unit 4. Add: when the handle goes stiff or the flow drops, tell the area mechanic the same day.

Card 5 · Sanitary inspection (yes or no list)

  • Apron cracked?
  • Water standing near the pump?
  • Latrine, rubbish pit or animals near the pump?
  • Drain blocked or broken?
  • Cap or cover missing?
  • Fence or gate broken?

The World Health Organization published new sanitary inspection forms for a tubewell with a hand pump and for a borehole with a motorised pump in 2024. This card is a simplified list; keep the laboratory test as the evidence of safe water.

Card 6 · Simple faults and who to call

Fault First check Call
No water from the hand pump Handle loose? Water level low? Area mechanic
Little flow, stiff handle Grease; bolts Area mechanic
Electric pump does not start Power at the board? Tank already full? Electrician
Pump runs, no water Valves open? Tank level? Technician, then electrician
Water tastes or smells wrong Stop drinking; test Laboratory and the WRC

Card 7 · Conversions

To change Multiply by
m3 to litres 1,000
L/s to m3/h 3.6
m3/h to L/min 16.67
bar to metres of water head about 10.2
HP to kW 0.746
US gallon to litres 3.785 (the Unit 6 text rounds this to 3.8)
inch to mm 25.4

Abbreviations

Short form Meaning
SWL Static water level
PWL Pumping water level
TDH Total dynamic head
WRC Water Resources Commission
CWSA Community Water and Sanitation Agency
WSMT, WATSAN Water and sanitation management team (community)
PPE Personal protective equipment
NTU Nephelometric turbidity units (cloudiness)
mg/L Milligrams per litre
13

Appendix B · What went wrong (cases)

Real lessons. Names and places are removed.

Ask a qualified expert. Cases are for learning. Do not copy a fix without a licensed driller, a certified electrician or a qualified engineer checking your own site.

Case What happened Cause What to do next time
1. The dry borehole A client paid for a hole and got no useful water No proper site assessment Use a desk study, a site walk and a survey by a qualified person before drilling
2. The pump that gave up A pump labelled for a large flow failed after a few days Rated far above what it delivered; chosen by price Check the maker's curve and test flow with a bucket
3. The seals A village pump kept stopping Rubber seals worn; none in stock Keep a spares kit and a trained mechanic
4. The skipped steps A new borehole gave muddy water Development, testing and completion were skipped Ask for the checklist and the completion record
5. Gush and lines Water shot upward near overhead lines Pressurised water layer; lines not checked Contact the power company first; keep the distance
6. Handpump study Many pumps in a field study were in poor condition Corroded and damaged rising mains; cylinders near the water level Use good parts; check pipes at every service
14

Appendix C · Common mistakes catalogue

Mistake What you will see How to avoid it
Drilling with no assessment Dry or salty hole Desk study, site walk, survey
Pump chosen by price Little water, short pump life Calculate depth, head and flow; read the curve
Believing the label Flow far below the label Bucket-and-stopwatch test
Open borehole Rubbish or a fallen child or animal Cap and fence
Wiring by a helper Shock, fire Certified electrician only
No spares for the hand pump Pump idle for days Keep a spares kit
Bleach mixed with other cleaners Poison fumes Never mix chemicals
Entering a tank Collapse from bad air Never enter
Skipping the licence check Poor job, legal trouble Ask for the WRC licence
No water test Unseen germs or salt Test at an accredited laboratory
15

Appendix D · Tools and Items Glossary

Every tool and part named in this book, with what it is and what it does. Local names differ from town to town: use the standard name and show the picture or the part. Sizes are general; check Ghana supplier data sheets (not verified for Ghana stock).

Item What it is and its use Size or type Who may handle Also called
Airlift (compressor and eductor pipe) Uses compressed air to lift water and mud from the hole during development. Per driller Driller air-lift development
Bailer and surge block Development tools. A bailer lifts mud out; a surge block moves water in and out of the screen to loosen fines. Per driller Driller sand bailer; mud bucket
Barrier tape and cones Mark an open borehole or work area so people and children keep away. Visible colour You danger tape; safety cones
Bobbin and rod centraliser Plastic guides that keep the pump rod in the middle of the rising main so it does not rub. Per pump model Area mechanic rod guide; centraliser
Breaker (MCB), RCD and fuse Switch off on overload or earth fault. The RCD protects people from shock. Amps; RCD mA set by the electrician Electrician circuit breaker; MCB; trip switch
Casing Plain pipe lining the borehole so it does not collapse and so water from above cannot get in. uPVC, steel or HDPE; diameter 100 to 200 mm Driller well casing; lining pipe
Check valve (non-return valve) Lets water flow one way only so the pipe does not drain and the pump does not spin backwards. Same size as the pipe; spring or swing Technician non-return valve (NRV); one-way valve
Chlorine (HTH granules or liquid bleach) The disinfectant. HTH is strong granular calcium hypochlorite (strength on the label); household bleach is weaker (often 3.5 to 5 percent: read the label). Strength on the label You (with trainer) calcium hypochlorite; sodium hypochlorite (bleach)
Clean hose, bucket and jug for sampling Clean tools for taking a sample without touching the inside of the bottle. Clean and rinsed You sampling hose
Concrete apron, drain and soak-away A concrete slab around the borehole head that sheds spilt water into a drain. Dimensions set by the designer You (assist) platform; pump base; wash slab
Conductivity (EC) or TDS meter Measures dissolved salts as electrical conductivity (uS/cm) or total dissolved solids (mg/L). A quick check for salty water, important near the coast. Use before and during pumping. 0 to 2,000 uS/cm or wider You EC meter; TDS meter; salinity meter
Control box or starter (DOL, star-delta) Switches and protects the motor. Opening it is electrician-only work. kW; phase Electrician starter; motor starter; control panel
Cup seal (piston seal) and U seal Rubber lips that seal the plunger against the cylinder wall. They wear first and are the most frequent repair on community hand pumps. Per pump model; use maker parts Area mechanic piston seal; bucket seal; U-seal
Cylinder and plunger (piston) The cylinder sits in the water. The plunger moves inside it and lifts water on each stroke. Per pump model Area mechanic pump cylinder; working barrel
Dip meter (water-level tape) A reel of graduated tape with a probe that beeps or lights when it touches water. It gives the static and pumping water level from a fixed mark on the casing. Use before and during pumping. Tape 50, 100 or 150 m You (with trainer) water level meter; well sounder; dip tape
Drilling rig, compressor, DTH hammer, drill bit, drill rods and mud pump The driller's machine and tools. A down-the-hole (DTH) hammer breaks hard rock with air; a mud pump circulates drilling fluid. You only need the names. Never operate them. Per driller Driller drill rig; drilling machine
Drop cable (submersible cable) Waterproof cable from the control box down to the motor. mm2; cores; length Electrician submersible cable; flat pump cable
First-aid kit Dressings, gloves and washing water. For injuries get a doctor or nurse; call 112 in an emergency. Kept complete You first-aid box
Float switch (tank) A float that rises with the water and stops or starts the pump at set levels. Type to suit the control Electrician and you float control; tank level switch
Gravel pack (filter pack) Clean, rounded, sized gravel around the screen. It holds back fine sand and keeps the slots open. Grain size in mm; volume Driller filter pack; gravel filter
Hacksaw, pipe wrench, spanners and vice The plumber's hand tools: cut pipe, grip and turn pipe, tighten bolts, hold work. Pipe wrench 14 to 24 inch You pipe saw
Hand pump (Afridev, India Mark II, Nira, Vergnet) A pump worked by arm or foot with no electricity. Afridev and India Mark II lift water with a handle, rods and a cylinder in the borehole; Nira and Vergnet are other designs on the CWSA list. India Mark II lifts to about 50 m Area mechanic village pump; community pump
Isolation valve (gate or ball valve) Opens or shuts the flow so one part can be cut off for repair. Pipe size; PN You stop valve; shut-off valve
Lock and tag (lock-out set) A padlock and tag put on the switch so nobody can switch on while work is being done. Electrician rules apply. Per site Electrician padlock and tag; lockout kit
Marked bucket (20 L) A bucket with the volume marked on it. Fill it from the spout or pipe and time it to measure flow (bucket test). Use at hand pumps, taps and pump outlets. 20 L; mark the full line with a measured jug You pail; measuring bucket
Measuring jug and clean bucket Measure and mix the dose of chlorine. 1 L jug; 10 to 20 L bucket You measuring cup
pH meter or pH strip Shows how acid or alkaline the water is, on a scale of 0 to 14. Use on a fresh sample. 0 to 14 You pH tester; pH strip
PPE: boots, gloves, safety glasses, hard hat and apron Protective gear for the eyes, hands, head and feet. Chemical gloves and glasses are needed for chlorine. Fit and size per person You safety gear; protective clothing
PTFE tape, jointing compound and solvent cement PTFE tape seals threaded joints; jointing compound seals larger threads; solvent cement welds uPVC pipe joints. Per product label You thread seal tape; plumber's tape
Pump head, handle and fulcrum The part above ground that you move. The handle turns the hand movement into up and down rod movement. Per pump model Caretaker pump head assembly
Pump rod and rod coupling Rods inside the rising main that carry the up and down movement to the plunger. Couplings join rods. Stainless steel or fibreglass; per metre Area mechanic sucker rod; lift rod
Resistivity set and GPS Instruments used by the hydrogeologist or driller to site a borehole. A trainee only needs the names. n/a Hydrogeologist resistivity meter; survey set
Rising main (drop pipe) The pipe that carries water from the pump up to the surface. uPVC, HDPE or galvanised steel; size; pressure class PN Technician drop pipe; riser pipe; column pipe
Sample bottles Sterile bottles from the laboratory for germ tests and clean bottles for chemistry. The laboratory tells you which and how to keep the sample. 250 or 500 mL You sample container; sample jar
Sanitary seal (cement or bentonite grout) A sealed collar near the top of the annulus so dirty surface water cannot run down the outside of the casing. Depth and material set by the driller Driller annular seal; grout seal; sanitary grout
Screen (slotted casing) Slotted pipe opposite the water-bearing layer. Water enters through the slots; sand is kept out. Slot size in mm; open area Driller well screen; slotted casing; strainer pipe
Screwdrivers, hammer and pliers Basic hand tools for the hand pump and tank. Standard sizes You hand tools
Solar panel (PV module) and array A panel makes DC power in daylight. An array is panels joined together. Wires can be live even when the pump is off. Wp per panel; number Licensed installer solar panel; PV panel
Solar pump and controller A pump driven by solar panels. The controller (with MPPT) converts and protects. Array kWp; voltage; flow and head Licensed installer solar borehole pump; PV pump
Spares kit (seals, rod couplings, bobbins and bolts) A box of the parts that wear most, kept by the committee so repairs are quick. Per pump model Committee and mechanic seal kit; repair kit
Stopwatch Times how long the bucket takes to fill. A phone stopwatch is fine. Seconds You timer
Submersible pump Pump and motor in one unit hung under the water. The pump end lifts the water and the motor drives it. Use for deep boreholes. Diameter 3, 4 or 6 inch; kW; single or three phase Electrician and technician submersible borehole pump; deep-well pump
Sump and centraliser The sump is a plain pipe below the screen where silt settles. Centralisers keep the casing in the middle of the hole. Casing size Driller tail pipe; bottom cap
Surface pump (jet or centrifugal) A pump above ground that sucks water up. Suction lift is limited to a few metres. Use from tanks and shallow sources. HP; suction size Technician centrifugal pump; jet pump; self-priming pump
Tank level gauge A float or sight tube that shows how full the tank is. Used in the monitoring log. Marked in litres You level gauge; sight tube
Tank, stand, overflow, vent screen and manhole cover Tank stores water; stand lifts it for pressure; overflow carries surplus away; vent screen keeps insects out; manhole cover is the lockable lid. Litres; plastic or concrete You (assist) storage tank; reservoir
Tape measure, plumb bob and spirit level Measure lengths and heights, hang a vertical line, and check that a tank base is level. 5 m to 30 m tape You measuring tape; plumb line and level
Test strips and colour comparator Small paper strips or colour charts for quick checks on pH, chlorine and hardness. Per product You test paper; colour chart
Test-pumping pump and generator (contractor's) The driller's test pump and its power for the yield test. Check that it can run the full test period. Flow and head to suit the test Driller contractor's test pump
Warning sign and fence A sign and fence around the water point to keep animals and children out. Visible You guard fence; warning board
Wellhead (well cap and seal plate) The top closure of the borehole. It carries the pipe and cable and keeps dirt and insects out. Fits the casing size Technician well cap; well seal; sanitary cap
16

Appendix E · Index

Look for Go to
Aquifer, recharge, water table Unit 2
Bleach dose Unit 6, Card in Appendix A
Bucket test Unit 5
Check valve Unit 5, Appendix D
Dry borehole case Unit 2 box, Appendix B
Drilling licence Unit 3, Appendix A Card 3
Hand pump parts Unit 4
Law card Appendix A
Overhead lines Unit 1 box
Salt (coast) Unit 2, Unit 6
Safety rules Unit 1, Appendix A Card 1
Sample bottle Unit 6
Seals Unit 4
Tools and items Appendix D
17

Further reading and sources

Best next reads: the RWSN India Mark II manual; the WRC website; your pump maker's manual; Basic Plumbing in this library for pipes and fittings; Solar Energy in this library for solar pumps; Boreholes and Water Pumps Level 2.

What this module does not cover: drilling, siting surveys, pump wiring, solar installation, pulling submersible pumps, well digging, water treatment plants, and current Ghana borehole prices (blog estimates only; ask licensed drillers for written quotes).

Every source used in this manual is listed, with links, in the Teacher Copy.

One application of the Cold-Start Learning Kit, which stays general-purpose and can build a guide on any topic in any field. Written in CTVET format; not a CTVET curriculum.