About this module
Clean water is the first thing a home, a farm or a school needs. A borehole gives it, but only if the borehole is sited, drilled, pumped and kept clean by people who know their work. This module teaches you the basics so you can help, learn more and earn.
Who it is for. People with no formal certificate, aged 18 or over. National Proficiency I is a bridging level for people with little or no formal education; holders do routine tasks under supervision. In Ghana, nobody under 18 may do hazardous work.
Why boreholes and pumps
- Rural and small-town water in Ghana depends heavily on boreholes. At its Western Region 25th anniversary in 2024, the Community Water and Sanitation Agency (CWSA) said it oversees 31,388 boreholes with hand pumps, 383 solar boreholes and 1,924 piped systems nationwide.
- Every pump, tank and hand pump needs someone to look after it. A hand-pump committee that has no mechanic nearby waits days for repairs.
- The Hub (HSM Agrictech and Innovation Hub) uses water for its farm, so you will see real tanks and pipes while you train.
This module is not a CTVET curriculum, and it is not a drilling course. The CTVET list of approved competency-based programmes that we found does not include borehole drilling, so we wrote this module from public sources. Ask a qualified expert. Drilling must be done by a company holding a Water Resources Commission (WRC) drilling licence. Pump wiring must be done by a certified electrician. This is general information, not legal advice; ask the Water Resources Commission or a qualified lawyer before you act on any licence matter.
Boreholes in Takoradi
The Sekondi-Takoradi Metropolitan Assembly (STMA) says master artisans must register all their trainees. Ground conditions differ from place to place, and we found no Western Region borehole success figure, so always ask a local licensed driller what they find in your area (not verified).
How the module works
Each unit has learning outcomes, performance criteria, the range and the evidence your assessor needs. You are judged Competent or Not Yet Competent by being watched at work, by answering questions, and by your logbook. Every unit ends with a practical task, homework and three "Check yourself" questions.
Unit 1 · Work safely at wells, pumps and tanks
A well or a tank can look harmless and still kill. Mains power and water are a dangerous mix. Learn these rules before you touch anything.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 1.1 Wear the right PPE | wears boots, gloves, safety glasses and cotton work clothes |
| 1.2 Stay out of confined spaces | refuses to enter a well, a tank, a pit or a borehole casing |
| 1.3 Respect electricity | treats every pump cable as live; leaves all wiring to a certified electrician |
| 1.4 Lift and carry safely | lifts with the legs; uses two or more people for heavy pump parts |
| 1.5 Keep a clean, safe site | covers openings; keeps children away; keeps tools tidy |
Range. Hand pump sites, pump rigs, tanks and workshop. Evidence. Observation every session; oral questions.
Ask a qualified expert. For electrical, gas, welding, chemical or other dangerous work, use a licensed electrician or a qualified safety officer. In Ghana, indoor and pump wiring belongs to an Energy Commission-certified electrician. Do not attempt work you are not trained and authorised to do. For any injury or illness, see a doctor or nurse. This unit teaches awareness and good practice, not medical treatment.
The big dangers
| Danger | What can happen | The rule |
|---|---|---|
| Wells, tanks, pits | Bad air or no air; you fall in; people die trying to rescue | Never enter. Call a trained rescue team or the fire service on 112 |
| Electricity | Shock, burns, death, especially with wet hands or wet ground | Switch off at the board; leave wiring to a certified electrician |
| Open boreholes and well mouths | A child or animal falls in; things drop in and pollute | Keep every opening capped or covered |
| Heavy pump parts and pipe | Back injury; crushed fingers | Lift with your legs; get a second person; use a rope and a stand |
| Sun, heat and long work | Heat illness | Drink water; rest in the shade |
| Chemicals (bleach, fuel, oil) | Burns; fumes; poisoning | Gloves and glasses; read the label; never mix chemicals |
(These are good-practice rules, not Ghana law.)
Never enter a well, tank or casing
A confined space is a place that is small, hard to leave and may hold bad air. People have died in wells and tanks because they went in to help or to clean. Stay outside. Clean tanks from the outside or with trained staff; ask a qualified safety officer for confined-space work.
Electricity and water
- Water carries electricity. A pump cable that looks fine can still be damaged.
- Never touch a pump, cable or control box with wet hands, and never plug in or switch on a pump you did not set up with a certified electrician.
- Pump wiring, earthing and protection are done by an Energy Commission-certified electrician; trainees may only assist with pipe and tank work.
- Solar pumps have panels that make power in daylight, so the wires can be live even when the pump is off. Leave solar wiring to a licensed installer.
Safe or unsafe?
Your trainer describes eight scenes. For each, say safe or unsafe and why.
Site safety walk
- Walk a hand-pump site or the Hub water point with your trainer.
- List every opening, cable, tank and chemical you see.
- For each, write the danger and the rule from the table.
- Check that every borehole opening is capped and the control box is closed.
- Put on your PPE and have a partner check it.
- Record the walk in your logbook.
Spot the danger
At home or near your house, find three water or electricity dangers (an open well, a loose cable, a leaking tank). Write what you would tell the owner. Do not touch anything.
From the field: When the water gushes into the sky
The moment. Drilling hit a pressurised water table and the water shot high into the air.
The problem. Near overhead high-tension lines, a shock is almost unavoidable. Some drills have gone through buried electric cables, with fatal injuries.
The cause. No one checked the surroundings or the power company before work began.
The lesson. Look up and look down before you drill.
Next time. 1. Watch the surroundings carefully. 2. Contact the power company before any work. 3. Keep clear of lines and cables and have a qualified supervisor on site.
Ask a qualified expert: the power company and a qualified safety officer.
International distance rule (not Ghana law). A common international rule for tall equipment near overhead lines is the United States OSHA table for cranes and derricks: keep at least about 3 m (10 ft) from lines up to 50 kV, about 4.6 m (15 ft) for over 50 to 200 kV, about 6.1 m (20 ft) for over 200 to 350 kV and about 7.6 m (25 ft) for over 350 to 500 kV. A training source says to use 6.1 m (20 ft) if you do not know the voltage. Rain, mist, fog and dust can carry current from a line to a rig mast. You do not know the line voltage, so ask the power company for it and for its own safe distance, and ask a qualified safety officer. Check this against the Energy Commission and power company rules when you read them (not verified for Ghana).
Safety protocol: working at a pump or borehole site
Before you start
- Walk the site with the owner and note every opening, cable, tank and chemical.
- Wear boots, gloves, safety glasses and cotton work clothes; check them with a partner.
- Confirm the pump is switched off and locked out by the electrician before any work near it.
- Cap or fence every open borehole.
- Check for overhead lines and tell the trainer if you see any.
While you work
- Do work in pairs; do keep children and animals away.
- Do not enter a well, tank or casing.
- Do not touch cables, control boxes or solar wiring.
- Do not lift heavy pump parts alone.
- Drink water and rest in the shade.
After
- Close and lock the control box and covers (do not open them yourself).
- Clean and store tools; count them.
- Report any damage, leak or open borehole to the trainer or owner.
Emergency
- Call 112 for any serious injury, fire, shock or someone trapped.
- Switch off the power at the board only if it is safe to reach it; never touch a person who may be in contact with live equipment.
- Give first aid you were trained to give and keep the person warm and still until help arrives. This is not medical advice.
Tools and items for this unit
| Item | What it is and its use | Size or type | Who may handle | Also called |
|---|---|---|---|---|
| PPE: boots, gloves, safety glasses, hard hat and apron | Protective gear for the eyes, hands, head and feet. Chemical gloves and glasses are needed for chlorine. | Fit and size per person | You | safety gear; protective clothing |
| Barrier tape and cones | Mark an open borehole or work area so people and children keep away. | Visible colour | You | danger tape; safety cones |
| First-aid kit | Dressings, gloves and washing water. For injuries get a doctor or nurse; call 112 in an emergency. | Kept complete | You | first-aid box |
| Warning sign and fence | A sign and fence around the water point to keep animals and children out. | Visible | You | guard fence; warning board |
| Lock and tag (lock-out set) | A padlock and tag put on the switch so nobody can switch on while work is being done. Electrician rules apply. | Per site | Electrician | padlock and tag; lockout kit |
Check yourself
- Why must you never go into a well or tank to rescue someone?
- Who may wire a pump in Ghana?
- Name two things to wear for pump work.
Unit 2 · Where borehole water comes from
Borehole water is rain that soaked into the ground years ago. If you understand where it hides, you understand why one borehole is rich and the next one dry.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 2.1 Explain groundwater | explains rain, infiltration, aquifer, water table and recharge in plain words |
| 2.2 Name borehole parts | names casing, screen, gravel pack, seal, apron and cap |
| 2.3 Explain yield and water level | explains yield, static water level and drawdown |
| 2.4 Read a simple borehole record | reads depth, water level and yield from a driller's record |
Range. Household and small-farm boreholes. Evidence. Labelled sketch; oral questions.
Ask a qualified expert. Where to drill, how deep and how much water you will get are questions for a hydrogeologist or a licensed driller. Do not promise a customer water at a certain depth. Ask the Water Resources Commission or a licensed driller. This is general information, not an engineering design.
How groundwater works
- Rain falls and some soaks into the soil. This is infiltration.
- The water moves down until it fills the tiny spaces in sand, gravel or cracked rock. A layer of rock or soil that holds and gives water is an aquifer.
- The top of the water-filled ground is the water table. It rises in the wet season and falls in the dry season.
- Water that soaks in to refill the aquifer is recharge. If people pump out more than recharge brings in, the water table keeps falling.
Pumping too much groundwater can harm the supply, so pumping should follow the water rules.
Why one borehole gives more than the next
Different rocks hold and give water differently. In a study of 2,788 boreholes in the Ashanti Region, boreholes in the Birimian rocks had a drilling success rate of about 91 percent and an average depth of about 53 m, while granitoid rocks had about 72 percent success and mostly low yields. That is another region, so it is an example, not a promise for Takoradi (not verified for Western Region). Water in cracked hard rock is found along cracks, so a borehole a few metres away can be dry.
The borehole and its parts
| Part | What it does |
|---|---|
| Casing | Plain pipe that keeps the hole open and stops the walls collapsing |
| Screen | Slotted pipe at the water-bearing layer that lets water in and keeps sand out |
| Gravel pack | Clean gravel around the screen that filters the water |
| Sanitary seal | Clay or cement near the top that stops dirty surface water running down the outside |
| Apron (platform) | Concrete slab around the top that carries spilt water away |
| Cap or pump base | Closes the top so nothing falls in |
Three words you must know
- Static water level (SWL): how far down the water stands when nobody is pumping.
- Drawdown: how much the water level drops while pumping.
- Yield: how much water the borehole gives, for example in litres per minute or cubic metres per hour (1 cubic metre = 1,000 litres).
The Ashanti study counted 30 to 60 litres per minute as medium yield and over 60 litres per minute as high yield.
Reading a record
A driller's record (example numbers) says: depth 52 m, static water level 14 m, pumped for 6 hours at 3 cubic metres per hour, water level during pumping 21 m. (1) How deep is the water below the ground when nobody pumps? (2) What was the drawdown? (3) How many litres per hour is the yield? (4) How many litres per minute?
Draw and label
- Draw a cut-through of a borehole: ground, soil, rock, water table and aquifer.
- Add the casing, screen, gravel pack, sanitary seal, apron and cap.
- Mark the static water level and draw a second line for the water level while pumping.
- Label the drawdown.
- Check your drawing with a partner and your trainer.
Ask a neighbour
Ask a household or farm with a borehole: how deep is it, how long ago was it drilled, and does the water drop in the dry season? Write three lines.
From the field: The borehole with no water
The moment. A client paid for a borehole and did not get the water he hoped for.
The problem. The hole was a total loss to the client.
The cause. No proper assessment was made to find the best place for the water.
The lesson. Find the water on paper before you look for it with a drill.
Next time. 1. Look at the land: low-lying places and the water table. 2. Read the geological map of the area. 3. Ask a qualified hydrogeologist before drilling.
Ask a qualified expert: a hydrogeologist or a licensed driller decides where to drill.
From the field: Salt and no water in some rocks
The moment. Near the coast and in some rock types the water comes out salty, or not at all. Yield changes a lot even on one plot.
The cause. Some rocks give salty water or no water. The geological map shows them.
The lesson. Two holes on one plot can give two different answers.
Next time. 1. Check the map before you choose the spot. 2. Test the water for salt before you buy a pump. 3. Do not promise a yield.
Ask a qualified expert: a hydrogeologist, and an accredited laboratory for the salt test.
Ghana groundwater at a glance (read this as a guide, not a promise)
| Rock or area | What studies say | Tag |
|---|---|---|
| Birimian rocks (Ashanti Region study) | About 90.6 percent of boreholes succeeded; mostly medium to high yield zones | Other region, example |
| Tarkwaian rocks (Ashanti Region study) | About 79.5 percent success; mostly medium yield | Other region, example |
| Granitoids (Ashanti Region study) | About 72.3 percent success; mostly low yield | Other region, example |
| Western Region, Mpohor | Borehole iron 0.17 to 0.58 mg/L | Western Region, one study |
| Coast | Salt-water intrusion into coastal aquifers is an emerging issue; the Keta basin is one example | Other region, warning |
| Whole country | The most productive aquifers are fractured and weathered zones in several rock groups, and safe yields are poorly known for most aquifers | National review |
No Takoradi or Western Region yield or success figure was found, so none is printed here. Ask a local licensed driller what they find in your area.
Salt near the coast. Salty groundwater is common close to the shore and a filter cannot take the salt out. Check it with a conductivity meter before a pump is bought. Ask a hydrogeologist or the Water Resources Commission before you promise anyone fresh water.
Parts of a borehole, every part labelled
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Cap or wellhead | Closes the top; carries pipe and cable | Keep it on and locked; never stand on it |
| 2 | Concrete apron | Sheds spilt water into a drain | Keep it clean and crack-free; do not store chemicals on it |
| 3 | Sanitary seal | Stops dirty surface water running down the outside of the casing | Never dig it out |
| 4 | Casing | Keeps the hole open | Never enter it |
| 5 | Static water level | Water depth when nobody pumps | Measure only with a dip meter, never by dropping stones or objects |
| 6 | Pumping level | Water depth when the pump runs; the gap is the drawdown | Record it; do not pump a borehole dry |
| 7 | Gravel pack | Filters the water at the screen | Driller only |
| 8 | Screen | Lets water in, keeps sand out | Driller only |
| 9 | Sump | Silt settles below the screen | Driller only |
| 10 | Aquifer | The water-bearing layer | Not to be polluted: keep pollution sources away |
| 11 | Water table | Top of the water-filled ground | It falls in the dry season |
A real dip meter
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Carrying handle | You hold the reel steady with it | Stand on firm ground; do not lean over an open casing |
| 2 | Reel | Stores the tape; you turn it to wind the tape in | Wind slowly; keep fingers clear of the reel |
| 3 | Graduated tape | Printed length marks show the depth to the water | Keep it clean; never let it touch a live cable |
| 4 | Probe | The steel end of the tape that senses the water | Lower it slowly; never into a casing with a live pump cable without the electrician's permission |
| 5 | Frame | Holds the reel upright when you set it down | Set it on a clean surface so the tape and probe stay clean |
Parts of a dip meter, every part labelled
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Reel and handle | Stores and winds the tape | Wind slowly; keep fingers clear of the reel |
| 2 | Graduated tape | Shows the depth in metres | Keep it clean; never let it touch a live cable |
| 3 | Buzzer and light | Show that the probe has touched water | Test it in a bucket before use |
| 4 | Battery cover | Holds the battery | Keep it dry and closed |
| 5 | Probe | Two contacts that sense water | Never lower it into a casing that has a live pump cable without the electrician's permission |
| 6 | Reference mark | The fixed point on the casing you measure from | Mark it with paint and record where it is |
| 7 | Water level | The reading | Record the time and whether the pump is on |
Safety protocol: using a dip meter
Before you start
- Ask the owner; confirm with the electrician that the pump is switched off and locked out, or that the casing has a separate access port.
- Test the buzzer in a bucket.
- Wear gloves and safety glasses; keep the borehole cap area clear.
While you work
- Do lower the probe slowly; do read at the same reference mark every time.
- Do not force the tape if it snags; do not lean over the open casing.
- Do not touch any cable.
After
- Wipe, dry and rewind the tape; remove the battery if the meter is stored for a long time.
- Replace the cap and padlock.
- Write the reading, time and date in the logbook; report a stuck tape.
Emergency
- Call 112 for any serious injury, fire, shock or someone trapped.
- Switch off the power at the board only if it is safe to reach it; never touch a person who may be in contact with live equipment.
- Give first aid you were trained to give and keep the person warm and still until help arrives. This is not medical advice.
Tools and items for this unit
| Item | What it is and its use | Size or type | Who may handle | Also called |
|---|---|---|---|---|
| Dip meter (water-level tape) | A reel of graduated tape with a probe that beeps or lights when it touches water. It gives the static and pumping water level from a fixed mark on the casing. Use before and during pumping. | Tape 50, 100 or 150 m | You (with trainer) | water level meter; well sounder; dip tape |
| Marked bucket (20 L) | A bucket with the volume marked on it. Fill it from the spout or pipe and time it to measure flow (bucket test). Use at hand pumps, taps and pump outlets. | 20 L; mark the full line with a measured jug | You | pail; measuring bucket |
| Stopwatch | Times how long the bucket takes to fill. A phone stopwatch is fine. | Seconds | You | timer |
| Conductivity (EC) or TDS meter | Measures dissolved salts as electrical conductivity (uS/cm) or total dissolved solids (mg/L). A quick check for salty water, important near the coast. Use before and during pumping. | 0 to 2,000 uS/cm or wider | You | EC meter; TDS meter; salinity meter |
| Resistivity set and GPS | Instruments used by the hydrogeologist or driller to site a borehole. A trainee only needs the names. | n/a | Hydrogeologist | resistivity meter; survey set |
| Casing | Plain pipe lining the borehole so it does not collapse and so water from above cannot get in. | uPVC, steel or HDPE; diameter 100 to 200 mm | Driller | well casing; lining pipe |
| Screen (slotted casing) | Slotted pipe opposite the water-bearing layer. Water enters through the slots; sand is kept out. | Slot size in mm; open area | Driller | well screen; slotted casing; strainer pipe |
| Gravel pack (filter pack) | Clean, rounded, sized gravel around the screen. It holds back fine sand and keeps the slots open. | Grain size in mm; volume | Driller | filter pack; gravel filter |
| Sanitary seal (cement or bentonite grout) | A sealed collar near the top of the annulus so dirty surface water cannot run down the outside of the casing. | Depth and material set by the driller | Driller | annular seal; grout seal; sanitary grout |
| Concrete apron, drain and soak-away | A concrete slab around the borehole head that sheds spilt water into a drain. | Dimensions set by the designer | You (assist) | platform; pump base; wash slab |
| Wellhead (well cap and seal plate) | The top closure of the borehole. It carries the pipe and cable and keeps dirt and insects out. | Fits the casing size | Technician | well cap; well seal; sanitary cap |
Check yourself
- What is the water table?
- What does the sanitary seal stop?
- A borehole's water stands 10 m down and drops to 16 m while pumping. What is the drawdown?
Unit 3 · The law and the licensed driller
You do not drill. You help people do it the right way. A trainee who knows the law protects the customer, the water and himself.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 3.1 Know who may drill | states that drilling needs a Water Resources Commission licence |
| 3.2 Know the penalties and duties | explains the risks of hiring an unlicensed driller |
| 3.3 Describe the drilling job | lists the main stages from siting to test pumping |
| 3.4 Know your own limits | refuses to drill, and refers customers to licensed drillers |
Range. Household and small-farm boreholes. Evidence. Role play; oral questions.
Ask a qualified expert. Drilling is only by licensed drillers. This is general information, not legal advice. Ask the Water Resources Commission (WRC) for the current rules, fees and forms, and ask a qualified lawyer before you act on any licence, permit or registration matter. Do not tell a customer that no permit is needed.
The rules we found
- Drilling needs a licence. Drilling a well without a WRC drilling licence is an offence under the Drilling Licence and Groundwater Development Regulations, 2006 (L.I. 1827); Regulation 23 sets a fine of up to 200 penalty units or up to 12 months in prison, or both.
- Enforcement is real. The WRC has fined firms GH¢60,000 and seized their rigs, says people who hire unlicensed drillers may be prosecuted, and says owners must register their boreholes.
- Constructing boreholes without a licence is illegal, the WRC has said. In 2024 the WRC said it was monitoring for unlicensed drillers.
- Water use rules are separate. The Water Use Regulations, 2001 (L.I. 1692) set water-use permit categories; a summary says small mechanical abstraction may be exempt from a permit but must still be registered, but the exact threshold was not verified. Ask the WRC.
- Pollution. A summary says boreholes must not be built so that they let pollution reach the groundwater. The exact rule text was not read; ask the WRC.
Not verified. We could not read the WRC's own application form, the fee, how long a licence lasts, or the exact distance a borehole must keep from a latrine or septic tank. One study warns that a borehole within 30 to 50 m of a septic tank is likely to be polluted. Treat that as a guide, and ask the WRC for the rule.
How a licensed driller works (the main stages)
This is general practice, not a Ghana step list. Your job is to know the stages so you can talk to customers.
- Siting. A survey (often an electrical resistivity survey) finds where water is likely.
- Drilling. A rig makes the hole. The driller keeps a log of the rock layers.
- Casing and screen. Pipe goes in; the screen sits at the water layer.
- Gravel pack and seal. Gravel around the screen; a clay or cement seal near the top.
- Development. The driller cleans the hole so it gives clear water.
- Test pumping. Water is pumped for hours and the levels are recorded to find the safe yield.
- Water test and disinfection. A sample goes to a laboratory.
- Handover. A record of depth, levels and yield, and the apron and cap are finished.
What you may and may not do
| You may | You may not |
|---|---|
| Explain the stages to a customer | Drill, or hire out as a driller |
| Ask a driller for his WRC licence before the customer pays | Tell a customer drilling needs no licence |
| Help the customer keep the driller's record | Pump from a borehole the driller has not finished and tested |
| Refer the customer to the WRC | Promise how much water the borehole will give |
Spot the problem
A customer says: "A man with a small rig will drill my borehole for half the price. He says he does not need a licence." What do you tell the customer? List three risks.
Role play: the cheap driller
- Work in pairs: one is the customer, one is the trainee.
- The customer wants the cheapest driller.
- The trainee explains the licence rule and what to ask for before work starts.
- Swap roles.
- Write the three questions you would ask any driller.
Ask the WRC
Find the contact of the WRC office that covers the Western Region (use the WRC website or ask your trainer). Write down how you would ask about a drilling licence. Do not phone for the Hub; your trainer will do that.
From the field: The driller with only a drilling machine
The problem. Most drilling companies skip steps, such as development and testing, because they have only the drilling machine and not the other equipment.
The lesson. A drilled hole is not a finished borehole.
Next time. 1. Ask before hiring what equipment they bring. 2. Insist on development and a pump test. 3. Ask for the completion record.
Ask a qualified expert: the Water Resources Commission and a qualified lawyer for the contract.
What a good driller must do and bring (owner's checklist)
- Shows a current Water Resources Commission drilling licence
- Has told the Commission before drilling starts (a summary says a contractor must notify the Commission before constructing a well; read the full text)
- Keeps a log of the rock layers as the hole goes down and gives you a copy
- Brings the equipment for the later steps: development tools (bailer, surge block or an airlift), a test pump and a way to measure flow and water level
- Develops the borehole until the water runs clear, then test pumps, then disinfects
- Gives you a completion record: depth, casing and screen, gravel pack, seal, water levels, test yield and water test (the RWSN Code of Practice has a suggested format)
Ask a qualified expert. This checklist is general good practice and a summary of the regulations. It is not legal advice. Ask the Water Resources Commission for the current rules and ask a qualified lawyer before signing a drilling contract.
Parts of a drilling rig (names only)
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Mast | Holds the rotary head and rods upright | Keep clear of overhead lines and below the mast when it moves |
| 2 | Rotary head | Turns the drill rods | Never go near moving parts; no loose clothes |
| 3 | Drill rods | Carry the turning force and air down | Keep hands clear when rods are joined |
| 4 | Drill bit (hammer bit) | Breaks the rock | Hot and sharp; driller only |
| 5 | Compressor | Gives high-pressure air for the hammer | Hoses can whip if they fail; stay clear |
| 6 | Truck chassis and levelling jacks | Carry and steady the rig | Do not walk under a raised or jacked load |
| 7 | Cab and controls | Where the driller works the machine | Driller only |
| 8 | Mud pit or discharge channel | Collects cuttings and water | Keep children away; deep mud can trap |
Safety protocol: visiting a drilling site (watching only)
Before you start
- Get the driller's and owner's permission; the trainer comes with you and no more than 8 trainees.
- Wear boots, hard hat, safety glasses, ear protection and gloves.
- Ask the driller where the overhead lines and buried cables are, and where to stand.
- Agree a stop signal and a meeting point.
While you work
- Do stay outside the marked danger zone and upwind of dust.
- Do not touch rods, hoses, the hammer or the controls.
- Do not stand near the hole when the driller blows out cuttings: water can gush up.
- Do not go near overhead lines or wet cables.
After
- Wash hands and face; check for cuts.
- Tell the trainer about any near miss.
- Write notes in your logbook; never take photos near live hazards unless the driller agrees.
Emergency
- Call 112 for any injury.
- If water gushes up near power lines, move away on the driller's signal and stay clear until the power company says it is safe.
- Do not run into the danger zone to help.
Tools and items for this unit
| Item | What it is and its use | Size or type | Who may handle | Also called |
|---|---|---|---|---|
| Drilling rig, compressor, DTH hammer, drill bit, drill rods and mud pump | The driller's machine and tools. A down-the-hole (DTH) hammer breaks hard rock with air; a mud pump circulates drilling fluid. You only need the names. Never operate them. | Per driller | Driller | drill rig; drilling machine |
| Casing | Plain pipe lining the borehole so it does not collapse and so water from above cannot get in. | uPVC, steel or HDPE; diameter 100 to 200 mm | Driller | well casing; lining pipe |
| Screen (slotted casing) | Slotted pipe opposite the water-bearing layer. Water enters through the slots; sand is kept out. | Slot size in mm; open area | Driller | well screen; slotted casing; strainer pipe |
| Sump and centraliser | The sump is a plain pipe below the screen where silt settles. Centralisers keep the casing in the middle of the hole. | Casing size | Driller | tail pipe; bottom cap |
| Gravel pack (filter pack) | Clean, rounded, sized gravel around the screen. It holds back fine sand and keeps the slots open. | Grain size in mm; volume | Driller | filter pack; gravel filter |
| Sanitary seal (cement or bentonite grout) | A sealed collar near the top of the annulus so dirty surface water cannot run down the outside of the casing. | Depth and material set by the driller | Driller | annular seal; grout seal; sanitary grout |
| Bailer and surge block | Development tools. A bailer lifts mud out; a surge block moves water in and out of the screen to loosen fines. | Per driller | Driller | sand bailer; mud bucket |
| Airlift (compressor and eductor pipe) | Uses compressed air to lift water and mud from the hole during development. | Per driller | Driller | air-lift development |
| Test-pumping pump and generator (contractor's) | The driller's test pump and its power for the yield test. Check that it can run the full test period. | Flow and head to suit the test | Driller | contractor's test pump |
Check yourself
- Who may drill a borehole in Ghana?
- Can a customer be in trouble for hiring an unlicensed driller?
- Name two stages of a drilling job.
Unit 4 · Hand pumps and community water points
A hand pump needs no electricity. But a hand pump that nobody looks after soon stops, and a village goes back to dirty water.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 4.1 Name hand pump parts | names handle, pump head, rising main, rods, cylinder and plinth |
| 4.2 Do a sanitary inspection | checks the apron, drainage, cap and surroundings and records faults |
| 4.3 Do caretaker checks | tightens, greases and cleans the water point |
| 4.4 Know who repairs | explains the area mechanic and committee roles |
Range. Community hand pumps (India Mark II type and similar), with the owner's permission. Evidence. Inspection sheet; oral questions.
Ask a qualified expert. Pulling a hand pump apart and replacing parts in the borehole is for a trained area mechanic. Water from a hand pump that tastes or smells wrong, or that people think made them ill, must be tested at an accredited laboratory: ask the Water Resources Commission and a health worker. Anyone who is ill should see a doctor or nurse. This is general information, not medical advice.
How a deep-well hand pump works
Moving the handle moves a rod up and down inside the rising main. At the bottom, a cylinder with a valve (a one-way door) lifts a little water on each stroke. The India Mark II is designed to lift water from deep wells up to about 50 m. Ghana's CWSA guidelines list four standard hand pumps: Nira, Afridev, the Ghana-modified India Mark II and the French Vergnet.
Who looks after it
Under the community-based model, a water and sanitation team signs a contract with an area mechanic for regular maintenance, and the mechanic is paid from water sales; each pump should have two trained caretakers, a man and a woman. Those guidelines are from 2010 and may have changed; ask your local CWSA or Assembly office (not verified for today).
Reality check. One monitoring summary found that half of the community management team members said it takes more than three days to get a mechanic. A trained local helper who can do the simple jobs fast keeps the village supplied.
Caretaker checks (daily, weekly, monthly)
| How often | Check |
|---|---|
| Every day | Look for leaks; spout and apron clean; no animals; cap and cover in place |
| Every week | Handle bolts tight; drainage channel clear; no standing water near the pump |
| Every month | Pump head and handle bearings greased as the maker says; fix small cracks in the apron; tell the mechanic about heavy or stiff handles |
(Good practice, from pump makers' manuals in general; follow your own pump's manual.)
Sanitary inspection
Walk around the water point and look for anything that can bring dirt to the water: a cracked apron, standing water, a latrine or rubbish pit near the pump, an uncovered opening, animals, a broken drain. Record each fault as yes or no and give the list to the committee.
Hand pump check
- Visit a hand pump with the committee's permission.
- Do the daily and weekly checks from the table. Time how long it takes to fill a 20-litre bucket and count the strokes.
- Do the sanitary inspection and write down every fault.
- Tighten loose handle bolts with the right spanner (do not open the pump).
- Fill in the inspection sheet and give a copy to the caretaker.
- Record it in your logbook.
Who is the mechanic?
Find out who the caretaker or area mechanic is for one hand pump near you. Ask how long the last repair took and what it cost. Write down the answer and the date.
From the field: The seal that always goes
The problem. On hand pumps the rubber seals fail most often.
The lesson. Keep spare seals before the pump stops.
Next time. 1. Keep a seal kit with the community. 2. Learn the replacement steps. 3. Check the seals at every visit.
Ask a qualified expert: the area mechanic does the replacement.
Hand pump parts card (Afridev and India Mark II type)
| Part (top to bottom) | What it does | Common fault |
|---|---|---|
| Handle and pump head | Turns your hand movement into rod movement | Loose bolts; worn bearings |
| Rising main | Carries the water up | Corroded steel pipe or cracked plastic pipe |
| Pump rods and couplings | Carry the movement down to the plunger | Loose or broken couplings |
| Cylinder and plunger | Lift the water at each stroke | Worn cup seal or U seal |
| Foot valve | Holds the water in the cylinder | Dirt under the valve |
A study that took apart 145 handpump boreholes in three African countries found the rising mains in poor condition, with 53 percent of galvanised pipes corroded and 82 percent of uPVC pipes damaged. The standard Afridev manual has a replacement-interval table for wearing parts.
Seals. Keep a set of seals in the spares kit. A caretaker does not replace seals inside the borehole: that is the area mechanic's job, using the maker's manual.
A real hand pump
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Handle | You move it up and down to work the pump | Keep fingers clear of the pivot; do not hang on it or let children swing on it |
| 2 | Pump head | Holds the pivot and joins the handle to the rods below | Report loose bolts or cracks to the area mechanic |
| 3 | Spout | The water comes out here | Keep the place under it clean; do not let dirty containers touch it |
| 4 | Column | Holds the head above the borehole and covers the pipe and rod inside | Do not unbolt it; opening it is the mechanic's job |
| 5 | Base plate | Sits on top of the borehole and keeps dirt out | Report a loose or cracked plate; never leave the borehole open |
| 6 | Concrete apron | A slab with a raised rim around the pump that keeps spilt water off the borehole | Keep it clean and the drain clear; report cracks |
Parts of a hand pump, every part labelled
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Handle | Your hand movement | Keep fingers clear of the pivot; do not hang on it |
| 2 | Fulcrum (pivot) | Lets the handle swing | Grease as the maker says; keep bolts tight |
| 3 | Pump head | Holds the handle and joins the rod to the main | Do not open; area mechanic only |
| 4 | Spout | Delivers the water | Keep the apron clean |
| 5 | Plinth and apron | Concrete base that sheds spilt water | Repair cracks; keep the drain clear |
| 6 | Rising main | Carries the water up | Mechanic only to pull |
| 7 | Pump rod | Moves the plunger | Do not pull; it can drop and injure |
| 8 | Cylinder | Where the water is lifted | Mechanic only |
| 9 | Plunger with cup seal | Seals and lifts; the seal wears first | Mechanic only; spare kit kept |
| 10 | Foot valve | Holds the water in the cylinder | Mechanic only |
| 11 | Casing | Lines the borehole | Never enter |
Safety protocol: hand pump caretaker checks
Before you start
- Wear gloves and boots; tell the committee you are checking.
- Bring the right spanner, grease, a clean bucket and a stopwatch.
- Look for children or animals near the pump.
While you work
- Do tighten loose handle bolts; do clear the drain; do grease as the maker says.
- Do not open the pump head or pull rods or pipes.
- Do not use the pump handle for hanging or lifting.
After
- Wipe the pump and apron; store tools.
- Record faults and the bucket-test time in the logbook.
- Tell the area mechanic the same day about a stiff handle, low flow or loose parts.
Emergency
- Call 112 for any serious injury, fire, shock or someone trapped.
- Switch off the power at the board only if it is safe to reach it; never touch a person who may be in contact with live equipment.
- Give first aid you were trained to give and keep the person warm and still until help arrives. This is not medical advice.
Tools and items for this unit
| Item | What it is and its use | Size or type | Who may handle | Also called |
|---|---|---|---|---|
| Hand pump (Afridev, India Mark II, Nira, Vergnet) | A pump worked by arm or foot with no electricity. Afridev and India Mark II lift water with a handle, rods and a cylinder in the borehole; Nira and Vergnet are other designs on the CWSA list. | India Mark II lifts to about 50 m | Area mechanic | village pump; community pump |
| Pump head, handle and fulcrum | The part above ground that you move. The handle turns the hand movement into up and down rod movement. | Per pump model | Caretaker | pump head assembly |
| Pump rod and rod coupling | Rods inside the rising main that carry the up and down movement to the plunger. Couplings join rods. | Stainless steel or fibreglass; per metre | Area mechanic | sucker rod; lift rod |
| Cylinder and plunger (piston) | The cylinder sits in the water. The plunger moves inside it and lifts water on each stroke. | Per pump model | Area mechanic | pump cylinder; working barrel |
| Cup seal (piston seal) and U seal | Rubber lips that seal the plunger against the cylinder wall. They wear first and are the most frequent repair on community hand pumps. | Per pump model; use maker parts | Area mechanic | piston seal; bucket seal; U-seal |
| Bobbin and rod centraliser | Plastic guides that keep the pump rod in the middle of the rising main so it does not rub. | Per pump model | Area mechanic | rod guide; centraliser |
| Spares kit (seals, rod couplings, bobbins and bolts) | A box of the parts that wear most, kept by the committee so repairs are quick. | Per pump model | Committee and mechanic | seal kit; repair kit |
| Marked bucket (20 L) | A bucket with the volume marked on it. Fill it from the spout or pipe and time it to measure flow (bucket test). Use at hand pumps, taps and pump outlets. | 20 L; mark the full line with a measured jug | You | pail; measuring bucket |
| Stopwatch | Times how long the bucket takes to fill. A phone stopwatch is fine. | Seconds | You | timer |
| Hacksaw, pipe wrench, spanners and vice | The plumber's hand tools: cut pipe, grip and turn pipe, tighten bolts, hold work. | Pipe wrench 14 to 24 inch | You | pipe saw |
| Screwdrivers, hammer and pliers | Basic hand tools for the hand pump and tank. | Standard sizes | You | hand tools |
Check yourself
- What does the rising main carry?
- Name two things you look for in a sanitary inspection.
- Who signs a contract with the area mechanic under the CWSA model?
Unit 5 · Electric and solar submersible pumps
A submersible pump works at the bottom of the borehole, out of sight. You must know what is down there, what the electrician does and what you do.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 5.1 Name the parts of a pump system | names pump, motor, rising main, cable, control box, float, tank and valves |
| 5.2 Choose between pump types | explains hand, submersible, surface and solar pumps and when each fits |
| 5.3 Assist with the pipework | pipes a pump to a tank with isolation and check valves |
| 5.4 Know the licences | states who may wire, who may install a solar pump |
Range. Household and small-farm systems. Evidence. Pump-and-tank rig; oral questions.
Ask a qualified expert. Pump wiring is for an Energy Commission-certified electrician, and a solar water pump must be installed by a licensed solar pump installer. Do not connect power, open the control box or touch solar wiring. For pipes and fittings, see Basic Plumbing in this library. This is general information, not legal advice.
The parts of a submersible system
- Pump and motor hang in the water inside the casing, below the lowest water level.
- Rising main (drop pipe) carries water up.
- Cable brings power down and must be rated for use in water.
- Control box or switch starts and protects the motor.
- Float switch in the tank stops the pump when the tank is full.
- Check valve and isolation valves stop water running back and let you cut off the pump for repair.
- Tank stores water so the pump does not run all day.
Which pump?
| Type | Where it sits | Good for | Watch out |
|---|---|---|---|
| Hand pump | On top of the borehole | Villages, no power | Slow; needs a caretaker |
| Submersible | Inside the borehole, under water | Deep boreholes; homes and farms | Wiring and pulling it up need skilled people |
| Surface pump | At the surface, next to the tank | Shallow water or tanks | Cannot lift from deep boreholes |
| Solar pump | Panels at the surface; pump in or beside the borehole | Farms and places without grid power | Needs a licensed installer; sized to the sun |
Do not buy a pump by price alone. Many cheap listings are sewage or garden pumps, and the pump must fit the borehole and the job.
The solar pump and the tank
A solar pump system has panels, a mounting, a pump controller, a surface or submersible pump, and pipes or a storage tank. Pumping water up to a raised tank is a cheaper way to store energy than batteries. In Ghana, a solar water pump installer needs an Energy Commission licence for solar pump service providers, a CEWP certificate for the solar side and an NVTI Grade 1 plumbing certificate for the pump side.
Pump-and-tank pipework (what you may do)
- Put the pump on a tank, not directly on the mains. Basic Plumbing in this library explains why connecting a pump to the mains is an illegal connection.
- Fit an isolation valve on each side of the pump, a check valve after it, and a float or automatic control. The electrician wires the control.
- Prices are examples: in Greater Accra listings in October 2026, a 1 HP submersible pump was about GH¢1,095 and a DC solar 1 HP surface pump was about GH¢6,500. These are classified-ad prices, not a market survey.
How long to fill?
Example: a pump gives 1,500 litres per hour (1.5 cubic metres per hour). (1) How long to fill a 1,000-litre tank from empty? (2) How long to fill a 3,000-litre tank? (3) A 1,000-litre tank was listed at about GH¢1,815. How much would three tanks cost?
Pump-and-tank rig
- Study a submersible pump (cut-away or spare) and name its parts.
- Pipe a small pump to a tank on the rig: isolation valve, pump, check valve, tank inlet, float, overflow.
- The certified electrician connects power. Stay clear of the control box.
- Fill the tank and write down the time; compare with the exercise.
- Check every joint for leaks, then record the work in your logbook.
Price check
Visit or phone two pump shops. Write down the price of a 1 HP submersible pump and a 1,000-litre tank, with the shop name and date.
From the field: The rating that was not true
The problem. Many pumps have a capacity written on them far above what they deliver, and give up after a few days.
The lesson. Do not trust the number on the box.
Next time. 1. Compare with the pump curve. 2. Test the flow with a bucket and a timer. 3. Keep the receipt and ask for a guarantee.
Ask a qualified expert: the pump supplier or a GhIE-registered engineer.
Bucket test for a pump outlet
- Fill the marked bucket from the pump outlet and start the stopwatch at the first drop.
- Stop the stopwatch when the bucket is full to the mark.
- Flow in litres per minute = 1,200 divided by the seconds taken (for a 20 L bucket).
- Flow in cubic metres per hour = 72 divided by the seconds taken.
- Example: 40 seconds gives 1,200 ÷ 40 = 30 L/min, which is 72 ÷ 40 = 1.8 m3/h.
Ask a qualified expert. Pump wiring, earthing and protection are for an Energy Commission-certified electrician, and solar wiring for a licensed solar installer. Do not open a control box. This is general information, not electrical advice.
A real submersible pump
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Power cable | Carries electricity to the motor | Never lift or carry the pump by its cable; the electrician makes every cable connection |
| 2 | Intake strainer (perforated band) | Water enters through the small holes; they keep out large grit | A pump set too deep in silt can block it; tell the driller if sand comes out |
| 3 | Steel body | The watertight casing around the working parts | Do not open it; never run the pump out of water |
| 4 | Threaded pipe end | A steel pipe fitting at one end of the pump, where the pipe joins | The installer makes this joint; ask the installer to check a badly rusted fitting |
Parts of a submersible pump system, every part labelled
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Wellhead cap | Closes the casing; holds pipe and cable | Keep locked |
| 2 | Casing | Lines the borehole | Never enter |
| 3 | Rising main | Carries water up | Pull only with trained people |
| 4 | Drop cable | Brings power to the motor | Treat as live; never touch or cut |
| 5 | Pump end | Lifts the water | Never touch when powered |
| 6 | Motor | Drives the pump end | Never touch when powered |
| 7 | Check valve | Stops water running back | Fit the arrow in the flow direction |
| 8 | Isolation valve | Lets you cut off water for repair | Close slowly |
| 9 | Control box | Starts and protects the pump | Closed and locked; electrician only |
| 10 | Tank | Stores water | Never enter |
| 11 | Float switch | Stops the pump when the tank is full | Electrician wires it; you only check the float moves freely |
| 12 | Overflow pipe | Carries away extra water | Keep it clear |
Safety protocol: working on a pump and tank (pipework only)
Before you start
- The electrician switches off, locks out and tests the circuit dead before you start; you see the lock.
- Wear gloves, glasses and boots; keep your hands dry.
- Check the isolation valve is closed and the tank base is level and strong.
While you work
- Do join pipes with the right fittings and PTFE tape; do check every joint for leaks.
- Do not open the control box or touch cables, even a damaged one.
- Do not switch the pump on yourself; do not run it dry.
After
- Clean up spilt water; remove tools.
- Tell the electrician when the pipework is finished; the electrician removes the lock.
- Write the work in your logbook.
Emergency
- Call 112 for any serious injury, fire, shock or someone trapped.
- Switch off the power at the board only if it is safe to reach it; never touch a person who may be in contact with live equipment.
- Give first aid you were trained to give and keep the person warm and still until help arrives. This is not medical advice.
Hand tools protocol
Safety protocol: hacksaw, pipe wrench and spanner use
Before you start
- Check the tool is the right size and in good condition; cracked handles are thrown away.
- Clamp the pipe in a vice or have a partner hold it; wear gloves and glasses.
While you work
- Do pull the wrench towards you; do cut away from your body.
- Do not use a pipe as an extension on a wrench; do not use a spanner as a hammer.
After
- Deburr cut edges; clean and store tools; count them.
- Report any damaged tool.
Emergency
- Cuts: press with a clean cloth and get a nurse or doctor. Call 112 for a severe injury.
Tools and items for this unit
| Item | What it is and its use | Size or type | Who may handle | Also called |
|---|---|---|---|---|
| Submersible pump | Pump and motor in one unit hung under the water. The pump end lifts the water and the motor drives it. Use for deep boreholes. | Diameter 3, 4 or 6 inch; kW; single or three phase | Electrician and technician | submersible borehole pump; deep-well pump |
| Control box or starter (DOL, star-delta) | Switches and protects the motor. Opening it is electrician-only work. | kW; phase | Electrician | starter; motor starter; control panel |
| Breaker (MCB), RCD and fuse | Switch off on overload or earth fault. The RCD protects people from shock. | Amps; RCD mA set by the electrician | Electrician | circuit breaker; MCB; trip switch |
| Float switch (tank) | A float that rises with the water and stops or starts the pump at set levels. | Type to suit the control | Electrician and you | float control; tank level switch |
| Drop cable (submersible cable) | Waterproof cable from the control box down to the motor. | mm2; cores; length | Electrician | submersible cable; flat pump cable |
| Rising main (drop pipe) | The pipe that carries water from the pump up to the surface. | uPVC, HDPE or galvanised steel; size; pressure class PN | Technician | drop pipe; riser pipe; column pipe |
| Check valve (non-return valve) | Lets water flow one way only so the pipe does not drain and the pump does not spin backwards. | Same size as the pipe; spring or swing | Technician | non-return valve (NRV); one-way valve |
| Isolation valve (gate or ball valve) | Opens or shuts the flow so one part can be cut off for repair. | Pipe size; PN | You | stop valve; shut-off valve |
| Tank, stand, overflow, vent screen and manhole cover | Tank stores water; stand lifts it for pressure; overflow carries surplus away; vent screen keeps insects out; manhole cover is the lockable lid. | Litres; plastic or concrete | You (assist) | storage tank; reservoir |
| Solar pump and controller | A pump driven by solar panels. The controller (with MPPT) converts and protects. | Array kWp; voltage; flow and head | Licensed installer | solar borehole pump; PV pump |
| Solar panel (PV module) and array | A panel makes DC power in daylight. An array is panels joined together. Wires can be live even when the pump is off. | Wp per panel; number | Licensed installer | solar panel; PV panel |
| PTFE tape, jointing compound and solvent cement | PTFE tape seals threaded joints; jointing compound seals larger threads; solvent cement welds uPVC pipe joints. | Per product label | You | thread seal tape; plumber's tape |
| Marked bucket (20 L) | A bucket with the volume marked on it. Fill it from the spout or pipe and time it to measure flow (bucket test). Use at hand pumps, taps and pump outlets. | 20 L; mark the full line with a measured jug | You | pail; measuring bucket |
| Stopwatch | Times how long the bucket takes to fill. A phone stopwatch is fine. | Seconds | You | timer |
Check yourself
- What does a check valve do?
- Who connects the power to a pump?
- Why is a raised tank useful with a solar pump?
Unit 6 · Storage, water quality and tests
Clear water is not always safe water. Germs and metals cannot be seen. The only way to know is to test.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 6.1 Keep stored water safe | keeps tanks closed, clean and covered |
| 6.2 Know common problems | names iron, germs and turbidity and the signs of each |
| 6.3 Take a water sample | fills a clean sample bottle the right way |
| 6.4 Clean and sanitise a small tank | uses the bleach dose with the trainer |
Range. Household and small-farm water. Evidence. Sample record; tank cleaning record; oral questions.
Ask a qualified expert. Water quality advice needs an expert. Ask the Water Resources Commission and test your water at an accredited laboratory before anyone drinks it. Treat the results as the expert's, not yours. Bleach is a chemical: wear gloves and glasses, never mix it with another cleaner, and keep children away. Anyone who is ill should see a doctor or nurse. This is general information, not medical advice.
What can be wrong with borehole water
- Iron and manganese make water taste of metal and leave brown or black stains. In a study of Mpohor in the Western Region, borehole iron ranged from 0.17 to 0.58 mg/L and manganese from 0.03 to 0.14 mg/L. The draft Ghana Standard asks for iron not above 0.3 mg/L. That standard was a public review draft, so check the final one, and note that sources differ on the iron limit (not verified).
- Germs. The draft standard asks for no E. coli or total coliform in 100 ml of drinking water. You cannot see germs. Only a laboratory test shows them.
- Muddy water (turbidity). The draft standard asks for turbidity not above 5 units and pH between 6.5 and 8.5.
- Some Ghana groundwater has iron or fluoride that need treatment, so test borehole water before drinking. An accredited Ghana Standards Authority laboratory is the place for a drinking-water test.
An example price: a water-quality test was estimated at GH¢300 to 800 in a 2026 article. This is a blog estimate; ask the laboratory.
Taking a sample
- Ask the laboratory for their own sterile bottle and their rules.
- Wash your hands; do not touch the inside of the cap or bottle.
- Run the tap or pump for a few minutes first.
- Fill the bottle, close it, label it (place, date, time, your name).
- Keep it cool and take it to the laboratory the same day, as the laboratory instructs.
Tank care and sanitising
- Keep tank lids closed and locked, and clean out dirt before you dose.
- To sanitise a household tank, use about 1 to 1.5 fluid ounces (2 to 3 tablespoons) of plain household bleach (5.25%) for every 500 US gallons, stir, close the tank and wait at least 8 hours; do not drink until the smell has gone. Convert the tank size from litres first (1 US gallon is about 3.8 litres).
- Do not enter the tank. Clean from outside or with trained staff.
Check the bleach. Bleach strengths differ by brand. Read the label; if it is not 5%, ask your trainer to help you adjust the dose.
Bleach dose
Example: a 2,000-litre tank. (1) How many US gallons is that (use 3.8 litres per gallon)? (2) The dose is 1 to 1.5 fluid ounces per 500 gallons. What is the dose range for this tank?
Sample and clean
- Practise taking a sample with a clean bottle from the Hub tap. Label it. (Your trainer decides whether to send it to a laboratory.)
- With the trainer, clean and sanitise a small tank from outside: remove dirt, calculate the dose, dose, close and wait.
- Put a clear notice on the tank: "Not for drinking until the smell has gone".
- Write the date, tank size, bleach strength and dose in your logbook.
Laboratory price
Phone or visit an accredited laboratory in Takoradi or Accra. Ask what a drinking-water test costs and how to bring the sample. Write the answer with the date.
Salt is common in borehole water near the coast. Ask for a salt (conductivity) check as well as the germ test.
Water test card
| What to check | Limit or guide | Who checks | Source and tag |
|---|---|---|---|
| E. coli and total coliform | None in 100 mL | Accredited laboratory | Draft Ghana Standard; WHO guidelines also say none |
| Iron | Not above 0.3 mg/L | Laboratory or iron test kit | Draft Ghana Standard, final text not read |
| Turbidity | Not above 5 NTU | Laboratory or turbidity tube | Draft Ghana Standard |
| pH | 6.5 to 8.5 | pH strip or meter | Draft Ghana Standard |
| Salt (conductivity) | Fresh water has low conductivity; ask the laboratory for the limit | Conductivity meter | Not verified for Ghana |
Sample bottle rules. Use the laboratory's own bottle; do not touch the inside of the cap or bottle; label place, date and time; keep cool; deliver the same day if the laboratory says so.
Tank cleaning card
- Wear gloves and glasses; never enter the tank
- Scrub and rinse from outside or have trained staff do it
- Dose with bleach as in this unit; calculate from the tank volume and the bleach strength on the label
- Close the lid, wait the time (at least 8 hours), then flush
- Put a notice "Not for drinking until the smell has gone"
- Write date, tank size, strength and dose in the logbook
Safety protocol: mixing bleach (chlorine) and cleaning a tank from outside
Before you start
- Read the label; know the strength (percent).
- Wear gloves, glasses, an apron and boots; work in open air.
- Have clean water ready to wash your skin or eyes.
- Never mix bleach with another cleaner, acid or fuel.
While you work
- Do measure with a jug, add bleach to water, not water to bleach, and stir with a clean stick.
- Do not breathe the fumes or enter the tank.
- Do not leave bleach where children can reach it.
After
- Close the tank; put the notice on it; wash tools and your hands.
- Store the bleach cool, closed and labelled.
- Write the date, tank size, strength and dose in the logbook.
Emergency
- Bleach in the eyes: rinse with clean water for 15 minutes and get a nurse or doctor (first aid, not medical advice). Swallowed: do not make the person vomit; call 112.
- Strong fumes: move to fresh air.
Tools and items for this unit
| Item | What it is and its use | Size or type | Who may handle | Also called |
|---|---|---|---|---|
| Sample bottles | Sterile bottles from the laboratory for germ tests and clean bottles for chemistry. The laboratory tells you which and how to keep the sample. | 250 or 500 mL | You | sample container; sample jar |
| Clean hose, bucket and jug for sampling | Clean tools for taking a sample without touching the inside of the bottle. | Clean and rinsed | You | sampling hose |
| pH meter or pH strip | Shows how acid or alkaline the water is, on a scale of 0 to 14. Use on a fresh sample. | 0 to 14 | You | pH tester; pH strip |
| Test strips and colour comparator | Small paper strips or colour charts for quick checks on pH, chlorine and hardness. | Per product | You | test paper; colour chart |
| Conductivity (EC) or TDS meter | Measures dissolved salts as electrical conductivity (uS/cm) or total dissolved solids (mg/L). A quick check for salty water, important near the coast. Use before and during pumping. | 0 to 2,000 uS/cm or wider | You | EC meter; TDS meter; salinity meter |
| Chlorine (HTH granules or liquid bleach) | The disinfectant. HTH is strong granular calcium hypochlorite (strength on the label); household bleach is weaker (often 3.5 to 5 percent: read the label). | Strength on the label | You (with trainer) | calcium hypochlorite; sodium hypochlorite (bleach) |
| Measuring jug and clean bucket | Measure and mix the dose of chlorine. | 1 L jug; 10 to 20 L bucket | You | measuring cup |
| PPE: boots, gloves, safety glasses, hard hat and apron | Protective gear for the eyes, hands, head and feet. Chemical gloves and glasses are needed for chlorine. | Fit and size per person | You | safety gear; protective clothing |
| Tank, stand, overflow, vent screen and manhole cover | Tank stores water; stand lifts it for pressure; overflow carries surplus away; vent screen keeps insects out; manhole cover is the lockable lid. | Litres; plastic or concrete | You (assist) | storage tank; reservoir |
Check yourself
- Can you tell by looking that water is safe to drink?
- Where should a drinking-water test be done?
- Why must you never enter a tank to clean it?
Unit 7 · Your location, business ideas and marketing yourself
You can earn without drilling a single hole. Water needs care, checking, cleaning and repair, in every town.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 7.1 Choose a good location | picks where customers have boreholes, tanks and pumps and few helpers |
| 7.2 List business ideas | names three lawful services he or she can offer |
| 7.3 Do simple money maths | works out cost, price and profit for a month |
| 7.4 Market yourself | sets up WhatsApp Business and asks for referrals |
Range. One small service business. Evidence. Costing sheet; one-page plan; oral questions.
Ask a qualified expert. Business registration, tax and loans need an expert. This is general information, not legal or financial advice. Check with the Sekondi-Takoradi Metropolitan Assembly, the Ghana Revenue Authority (GRA) or a qualified accountant before you register or borrow. Never advertise drilling, wiring or solar installation unless you hold the licence.
Where there is work
- Homes, schools, clinics, churches and farms with a borehole and a tank.
- Places far from town where a mechanic takes days to come: a trained local helper is valuable.
- Near suppliers and shops, so you can buy fittings fast.
Business ideas you may lawfully offer
| Service | Notes |
|---|---|
| Hand pump caretaker or helper to the area mechanic | Under the committee or mechanic; no drilling |
| Pump-and-tank pipework helper | With a licensed plumber or contractor; electrician does wiring |
| Tank cleaning from outside, water sampling runs | Never enter a tank; use the laboratory |
| Water point inspection reports for farms and schools | Sanitary inspection sheet |
| Selling fittings and spares | Shop or mobile |
Stay inside the law: no drilling without a WRC licence, no wiring without certification and no solar pump installation without the Energy Commission licences.
Money maths (all numbers are examples)
One month as a hand-pump and tank helper
You do 4 service jobs in a month. Each job: you charge GH¢150; parts and grease cost GH¢40; transport costs GH¢20. (1) Total income? (2) Total costs? (3) Profit? (4) Profit as a share of income, as a percentage?
Marketing yourself
- Set up WhatsApp Business with your name, services and area.
- Ask every happy customer for a referral and a photo of the finished job (with permission).
- Keep a simple portfolio: photo, date, what you did.
- Put a Google Business Profile in your name when you have steady customers.
- Never promise what you may not do: no "borehole drilling" if you are not licensed.
Registering
A sole proprietor business name was GH¢130 to register at the Office of the Registrar of Companies in 2026, with GH¢70 a year to renew. Assembly operating permits are applied for through the Assembly; fees are in the STMA fee-fixing resolution. Ask STMA which permit applies to you (not verified).
Accessibility
Persons with disabilities can do many tasks in this field. Under the Persons with Disability Act 2006, you have the right to training and work. Workable tasks: written sanitary-inspection sheets, record keeping, water-sampling runs, shop and parts sales, WhatsApp marketing, customer visits, tank-level logs. Helpful changes: a helper for heavy lifting, a stool at the bench, large-print or voice-note checklists, and clear step cards for deaf trainees. Ask the Assembly or the Department of Social Welfare about support.
Your one-page plan
- Choose one service from the table.
- Write the area you will serve and ten possible customers.
- List your tools and parts and what they cost (example prices are fine).
- Work out a price for one job.
- Write a WhatsApp Business message to introduce yourself.
- Show your plan to your trainer.
Three customers
Ask three people with a tank, pump or hand pump what problem costs them most. Write their answers and what you could offer.
Tools and items for this unit
| Item | What it is and its use | Size or type | Who may handle | Also called |
|---|---|---|---|---|
| Hacksaw, pipe wrench, spanners and vice | The plumber's hand tools: cut pipe, grip and turn pipe, tighten bolts, hold work. | Pipe wrench 14 to 24 inch | You | pipe saw |
| Screwdrivers, hammer and pliers | Basic hand tools for the hand pump and tank. | Standard sizes | You | hand tools |
| PTFE tape, jointing compound and solvent cement | PTFE tape seals threaded joints; jointing compound seals larger threads; solvent cement welds uPVC pipe joints. | Per product label | You | thread seal tape; plumber's tape |
| Spares kit (seals, rod couplings, bobbins and bolts) | A box of the parts that wear most, kept by the committee so repairs are quick. | Per pump model | Committee and mechanic | seal kit; repair kit |
| Marked bucket (20 L) | A bucket with the volume marked on it. Fill it from the spout or pipe and time it to measure flow (bucket test). Use at hand pumps, taps and pump outlets. | 20 L; mark the full line with a measured jug | You | pail; measuring bucket |
| Stopwatch | Times how long the bucket takes to fill. A phone stopwatch is fine. | Seconds | You | timer |
| Sample bottles | Sterile bottles from the laboratory for germ tests and clean bottles for chemistry. The laboratory tells you which and how to keep the sample. | 250 or 500 mL | You | sample container; sample jar |
Check yourself
- Name two services you may offer without a drilling licence.
- Why must you never advertise drilling?
- A job earns GH¢200 and costs GH¢80. What is the profit?
Glossary
| Term | Meaning |
|---|---|
| Aquifer | Rock or soil layer that holds and gives water |
| Apron | Concrete slab around a borehole or hand pump |
| Area mechanic | Trained person paid to look after hand pumps |
| Casing | Plain pipe that keeps a borehole open |
| Competent / Not Yet Competent | The two possible results of a CBT assessment |
| Drawdown | How far the water level drops when pumping |
| Gravel pack | Clean gravel around the screen |
| Recharge | Rain water that refills the aquifer |
| Rising main | The pipe that carries water up |
| Sanitary seal | Clay or cement that stops dirty water running down the hole |
| Static water level | Water depth when nobody is pumping |
| Yield | How much water a borehole gives |
Logbook
Copy these pages into an exercise book. Your logbook is part of your assessment evidence.
- Unit 1: site safety walk; dangers list
- Unit 2: labelled borehole drawing; record reading
- Unit 3: role play notes; questions for a driller
- Unit 4: hand pump checks; sanitary inspection sheet; bucket test
- Unit 5: pump parts list; rig record; price check
- Unit 6: sample record; tank cleaning record; laboratory price
- Unit 7: costing sheet; one-page plan; customers list
- Every homework, dated
Self-check quiz
- Why must you never enter a well or tank?
- Who may wire a pump in Ghana?
- What is the water table?
- What does the sanitary seal stop?
- What is drawdown?
- Who may drill a borehole?
- What can happen to a person who hires an unlicensed driller?
- Name two checks a hand pump caretaker does.
- Which pipe carries water up from a submersible pump?
- Why is a float switch fitted in the tank?
- Why test borehole water at an accredited laboratory?
- Name two services you may offer without a drilling licence.
Appendix A · Bench card pack
One page each. Print them and keep them in your toolbox. Numbers marked international come from foreign standards and must be checked against the Ghana text when you read it.
Ask a qualified expert. These cards give good practice for electrical, chemical, pressure and lifting hazards. They are not a substitute for a certified electrician, a licensed driller or a qualified safety officer. Water quality advice must come from an accredited laboratory and the Water Resources Commission. This is general information, not legal or medical advice.
Card 1 · Safety
| Hazard | Rule |
|---|---|
| Well, tank, pit, casing | Never enter. Call trained rescue or 112 |
| Electricity | Switch off, lock out, and leave wiring to the certified electrician. Water carries current |
| Overhead lines | Ask the power company before work; keep the distance in the Unit 1 box (international rule) |
| Buried cables | Ask the power company and utilities before any digging or drilling |
| Pressurised water | A drill can hit water that shoots up high. Stand clear and follow the driller's stop signal |
| Lifting | Two people for heavy pump parts; never lift with your back |
| Chemicals | Gloves and glasses; never mix chemicals |
| Open holes | Cap or cover every borehole opening |
Card 2 · Parts of a borehole and pump (what you see)
| Part | Where | Tag |
|---|---|---|
| Borehole cap or wellhead | On top of the casing | Do not remove |
| Apron | Concrete around the head | Check for cracks |
| Rising main | Pipe from the pump up | Technician only |
| Drop cable and control box | Wire down; box on the wall | Do not touch; electrician only |
| Float and tank | Float in the tank stops the pump | You may check from outside |
| Hand pump head, handle | Above the borehole | Caretaker greases and tightens |
Card 3 · Law (who does what)
| Rule | Who | What it means for you |
|---|---|---|
| Drilling licence (L.I. 1827) | Water Resources Commission; the drilling company | Drilling without a licence is an offence; ask for the licence |
| Register your borehole | Owner | The WRC says owners must register boreholes |
| Water use rules (L.I. 1692) | WRC | Permit categories; exact exemption threshold not verified |
| Wiring and solar pumps | Energy Commission-certified electrician; licensed solar installer | You assist; you do not connect |
Card 4 · Hand pump caretaker (daily, weekly, monthly)
See the table in Unit 4. Add: when the handle goes stiff or the flow drops, tell the area mechanic the same day.
Card 5 · Sanitary inspection (yes or no list)
- Apron cracked?
- Water standing near the pump?
- Latrine, rubbish pit or animals near the pump?
- Drain blocked or broken?
- Cap or cover missing?
- Fence or gate broken?
The World Health Organization published new sanitary inspection forms for a tubewell with a hand pump and for a borehole with a motorised pump in 2024. This card is a simplified list; keep the laboratory test as the evidence of safe water.
Card 6 · Simple faults and who to call
| Fault | First check | Call |
|---|---|---|
| No water from the hand pump | Handle loose? Water level low? | Area mechanic |
| Little flow, stiff handle | Grease; bolts | Area mechanic |
| Electric pump does not start | Power at the board? Tank already full? | Electrician |
| Pump runs, no water | Valves open? Tank level? | Technician, then electrician |
| Water tastes or smells wrong | Stop drinking; test | Laboratory and the WRC |
Card 7 · Conversions
| To change | Multiply by |
|---|---|
| m3 to litres | 1,000 |
| L/s to m3/h | 3.6 |
| m3/h to L/min | 16.67 |
| bar to metres of water head | about 10.2 |
| HP to kW | 0.746 |
| US gallon to litres | 3.785 (the Unit 6 text rounds this to 3.8) |
| inch to mm | 25.4 |
Abbreviations
| Short form | Meaning |
|---|---|
| SWL | Static water level |
| PWL | Pumping water level |
| TDH | Total dynamic head |
| WRC | Water Resources Commission |
| CWSA | Community Water and Sanitation Agency |
| WSMT, WATSAN | Water and sanitation management team (community) |
| PPE | Personal protective equipment |
| NTU | Nephelometric turbidity units (cloudiness) |
| mg/L | Milligrams per litre |
Appendix B · What went wrong (cases)
Real lessons. Names and places are removed.
Ask a qualified expert. Cases are for learning. Do not copy a fix without a licensed driller, a certified electrician or a qualified engineer checking your own site.
| Case | What happened | Cause | What to do next time |
|---|---|---|---|
| 1. The dry borehole | A client paid for a hole and got no useful water | No proper site assessment | Use a desk study, a site walk and a survey by a qualified person before drilling |
| 2. The pump that gave up | A pump labelled for a large flow failed after a few days | Rated far above what it delivered; chosen by price | Check the maker's curve and test flow with a bucket |
| 3. The seals | A village pump kept stopping | Rubber seals worn; none in stock | Keep a spares kit and a trained mechanic |
| 4. The skipped steps | A new borehole gave muddy water | Development, testing and completion were skipped | Ask for the checklist and the completion record |
| 5. Gush and lines | Water shot upward near overhead lines | Pressurised water layer; lines not checked | Contact the power company first; keep the distance |
| 6. Handpump study | Many pumps in a field study were in poor condition | Corroded and damaged rising mains; cylinders near the water level | Use good parts; check pipes at every service |
Appendix C · Common mistakes catalogue
| Mistake | What you will see | How to avoid it |
|---|---|---|
| Drilling with no assessment | Dry or salty hole | Desk study, site walk, survey |
| Pump chosen by price | Little water, short pump life | Calculate depth, head and flow; read the curve |
| Believing the label | Flow far below the label | Bucket-and-stopwatch test |
| Open borehole | Rubbish or a fallen child or animal | Cap and fence |
| Wiring by a helper | Shock, fire | Certified electrician only |
| No spares for the hand pump | Pump idle for days | Keep a spares kit |
| Bleach mixed with other cleaners | Poison fumes | Never mix chemicals |
| Entering a tank | Collapse from bad air | Never enter |
| Skipping the licence check | Poor job, legal trouble | Ask for the WRC licence |
| No water test | Unseen germs or salt | Test at an accredited laboratory |
Appendix D · Tools and Items Glossary
Every tool and part named in this book, with what it is and what it does. Local names differ from town to town: use the standard name and show the picture or the part. Sizes are general; check Ghana supplier data sheets (not verified for Ghana stock).
| Item | What it is and its use | Size or type | Who may handle | Also called |
|---|---|---|---|---|
| Airlift (compressor and eductor pipe) | Uses compressed air to lift water and mud from the hole during development. | Per driller | Driller | air-lift development |
| Bailer and surge block | Development tools. A bailer lifts mud out; a surge block moves water in and out of the screen to loosen fines. | Per driller | Driller | sand bailer; mud bucket |
| Barrier tape and cones | Mark an open borehole or work area so people and children keep away. | Visible colour | You | danger tape; safety cones |
| Bobbin and rod centraliser | Plastic guides that keep the pump rod in the middle of the rising main so it does not rub. | Per pump model | Area mechanic | rod guide; centraliser |
| Breaker (MCB), RCD and fuse | Switch off on overload or earth fault. The RCD protects people from shock. | Amps; RCD mA set by the electrician | Electrician | circuit breaker; MCB; trip switch |
| Casing | Plain pipe lining the borehole so it does not collapse and so water from above cannot get in. | uPVC, steel or HDPE; diameter 100 to 200 mm | Driller | well casing; lining pipe |
| Check valve (non-return valve) | Lets water flow one way only so the pipe does not drain and the pump does not spin backwards. | Same size as the pipe; spring or swing | Technician | non-return valve (NRV); one-way valve |
| Chlorine (HTH granules or liquid bleach) | The disinfectant. HTH is strong granular calcium hypochlorite (strength on the label); household bleach is weaker (often 3.5 to 5 percent: read the label). | Strength on the label | You (with trainer) | calcium hypochlorite; sodium hypochlorite (bleach) |
| Clean hose, bucket and jug for sampling | Clean tools for taking a sample without touching the inside of the bottle. | Clean and rinsed | You | sampling hose |
| Concrete apron, drain and soak-away | A concrete slab around the borehole head that sheds spilt water into a drain. | Dimensions set by the designer | You (assist) | platform; pump base; wash slab |
| Conductivity (EC) or TDS meter | Measures dissolved salts as electrical conductivity (uS/cm) or total dissolved solids (mg/L). A quick check for salty water, important near the coast. Use before and during pumping. | 0 to 2,000 uS/cm or wider | You | EC meter; TDS meter; salinity meter |
| Control box or starter (DOL, star-delta) | Switches and protects the motor. Opening it is electrician-only work. | kW; phase | Electrician | starter; motor starter; control panel |
| Cup seal (piston seal) and U seal | Rubber lips that seal the plunger against the cylinder wall. They wear first and are the most frequent repair on community hand pumps. | Per pump model; use maker parts | Area mechanic | piston seal; bucket seal; U-seal |
| Cylinder and plunger (piston) | The cylinder sits in the water. The plunger moves inside it and lifts water on each stroke. | Per pump model | Area mechanic | pump cylinder; working barrel |
| Dip meter (water-level tape) | A reel of graduated tape with a probe that beeps or lights when it touches water. It gives the static and pumping water level from a fixed mark on the casing. Use before and during pumping. | Tape 50, 100 or 150 m | You (with trainer) | water level meter; well sounder; dip tape |
| Drilling rig, compressor, DTH hammer, drill bit, drill rods and mud pump | The driller's machine and tools. A down-the-hole (DTH) hammer breaks hard rock with air; a mud pump circulates drilling fluid. You only need the names. Never operate them. | Per driller | Driller | drill rig; drilling machine |
| Drop cable (submersible cable) | Waterproof cable from the control box down to the motor. | mm2; cores; length | Electrician | submersible cable; flat pump cable |
| First-aid kit | Dressings, gloves and washing water. For injuries get a doctor or nurse; call 112 in an emergency. | Kept complete | You | first-aid box |
| Float switch (tank) | A float that rises with the water and stops or starts the pump at set levels. | Type to suit the control | Electrician and you | float control; tank level switch |
| Gravel pack (filter pack) | Clean, rounded, sized gravel around the screen. It holds back fine sand and keeps the slots open. | Grain size in mm; volume | Driller | filter pack; gravel filter |
| Hacksaw, pipe wrench, spanners and vice | The plumber's hand tools: cut pipe, grip and turn pipe, tighten bolts, hold work. | Pipe wrench 14 to 24 inch | You | pipe saw |
| Hand pump (Afridev, India Mark II, Nira, Vergnet) | A pump worked by arm or foot with no electricity. Afridev and India Mark II lift water with a handle, rods and a cylinder in the borehole; Nira and Vergnet are other designs on the CWSA list. | India Mark II lifts to about 50 m | Area mechanic | village pump; community pump |
| Isolation valve (gate or ball valve) | Opens or shuts the flow so one part can be cut off for repair. | Pipe size; PN | You | stop valve; shut-off valve |
| Lock and tag (lock-out set) | A padlock and tag put on the switch so nobody can switch on while work is being done. Electrician rules apply. | Per site | Electrician | padlock and tag; lockout kit |
| Marked bucket (20 L) | A bucket with the volume marked on it. Fill it from the spout or pipe and time it to measure flow (bucket test). Use at hand pumps, taps and pump outlets. | 20 L; mark the full line with a measured jug | You | pail; measuring bucket |
| Measuring jug and clean bucket | Measure and mix the dose of chlorine. | 1 L jug; 10 to 20 L bucket | You | measuring cup |
| pH meter or pH strip | Shows how acid or alkaline the water is, on a scale of 0 to 14. Use on a fresh sample. | 0 to 14 | You | pH tester; pH strip |
| PPE: boots, gloves, safety glasses, hard hat and apron | Protective gear for the eyes, hands, head and feet. Chemical gloves and glasses are needed for chlorine. | Fit and size per person | You | safety gear; protective clothing |
| PTFE tape, jointing compound and solvent cement | PTFE tape seals threaded joints; jointing compound seals larger threads; solvent cement welds uPVC pipe joints. | Per product label | You | thread seal tape; plumber's tape |
| Pump head, handle and fulcrum | The part above ground that you move. The handle turns the hand movement into up and down rod movement. | Per pump model | Caretaker | pump head assembly |
| Pump rod and rod coupling | Rods inside the rising main that carry the up and down movement to the plunger. Couplings join rods. | Stainless steel or fibreglass; per metre | Area mechanic | sucker rod; lift rod |
| Resistivity set and GPS | Instruments used by the hydrogeologist or driller to site a borehole. A trainee only needs the names. | n/a | Hydrogeologist | resistivity meter; survey set |
| Rising main (drop pipe) | The pipe that carries water from the pump up to the surface. | uPVC, HDPE or galvanised steel; size; pressure class PN | Technician | drop pipe; riser pipe; column pipe |
| Sample bottles | Sterile bottles from the laboratory for germ tests and clean bottles for chemistry. The laboratory tells you which and how to keep the sample. | 250 or 500 mL | You | sample container; sample jar |
| Sanitary seal (cement or bentonite grout) | A sealed collar near the top of the annulus so dirty surface water cannot run down the outside of the casing. | Depth and material set by the driller | Driller | annular seal; grout seal; sanitary grout |
| Screen (slotted casing) | Slotted pipe opposite the water-bearing layer. Water enters through the slots; sand is kept out. | Slot size in mm; open area | Driller | well screen; slotted casing; strainer pipe |
| Screwdrivers, hammer and pliers | Basic hand tools for the hand pump and tank. | Standard sizes | You | hand tools |
| Solar panel (PV module) and array | A panel makes DC power in daylight. An array is panels joined together. Wires can be live even when the pump is off. | Wp per panel; number | Licensed installer | solar panel; PV panel |
| Solar pump and controller | A pump driven by solar panels. The controller (with MPPT) converts and protects. | Array kWp; voltage; flow and head | Licensed installer | solar borehole pump; PV pump |
| Spares kit (seals, rod couplings, bobbins and bolts) | A box of the parts that wear most, kept by the committee so repairs are quick. | Per pump model | Committee and mechanic | seal kit; repair kit |
| Stopwatch | Times how long the bucket takes to fill. A phone stopwatch is fine. | Seconds | You | timer |
| Submersible pump | Pump and motor in one unit hung under the water. The pump end lifts the water and the motor drives it. Use for deep boreholes. | Diameter 3, 4 or 6 inch; kW; single or three phase | Electrician and technician | submersible borehole pump; deep-well pump |
| Sump and centraliser | The sump is a plain pipe below the screen where silt settles. Centralisers keep the casing in the middle of the hole. | Casing size | Driller | tail pipe; bottom cap |
| Surface pump (jet or centrifugal) | A pump above ground that sucks water up. Suction lift is limited to a few metres. Use from tanks and shallow sources. | HP; suction size | Technician | centrifugal pump; jet pump; self-priming pump |
| Tank level gauge | A float or sight tube that shows how full the tank is. Used in the monitoring log. | Marked in litres | You | level gauge; sight tube |
| Tank, stand, overflow, vent screen and manhole cover | Tank stores water; stand lifts it for pressure; overflow carries surplus away; vent screen keeps insects out; manhole cover is the lockable lid. | Litres; plastic or concrete | You (assist) | storage tank; reservoir |
| Tape measure, plumb bob and spirit level | Measure lengths and heights, hang a vertical line, and check that a tank base is level. | 5 m to 30 m tape | You | measuring tape; plumb line and level |
| Test strips and colour comparator | Small paper strips or colour charts for quick checks on pH, chlorine and hardness. | Per product | You | test paper; colour chart |
| Test-pumping pump and generator (contractor's) | The driller's test pump and its power for the yield test. Check that it can run the full test period. | Flow and head to suit the test | Driller | contractor's test pump |
| Warning sign and fence | A sign and fence around the water point to keep animals and children out. | Visible | You | guard fence; warning board |
| Wellhead (well cap and seal plate) | The top closure of the borehole. It carries the pipe and cable and keeps dirt and insects out. | Fits the casing size | Technician | well cap; well seal; sanitary cap |
Appendix E · Index
| Look for | Go to |
|---|---|
| Aquifer, recharge, water table | Unit 2 |
| Bleach dose | Unit 6, Card in Appendix A |
| Bucket test | Unit 5 |
| Check valve | Unit 5, Appendix D |
| Dry borehole case | Unit 2 box, Appendix B |
| Drilling licence | Unit 3, Appendix A Card 3 |
| Hand pump parts | Unit 4 |
| Law card | Appendix A |
| Overhead lines | Unit 1 box |
| Salt (coast) | Unit 2, Unit 6 |
| Safety rules | Unit 1, Appendix A Card 1 |
| Sample bottle | Unit 6 |
| Seals | Unit 4 |
| Tools and items | Appendix D |
Further reading and sources
Best next reads: the RWSN India Mark II manual; the WRC website; your pump maker's manual; Basic Plumbing in this library for pipes and fittings; Solar Energy in this library for solar pumps; Boreholes and Water Pumps Level 2.
What this module does not cover: drilling, siting surveys, pump wiring, solar installation, pulling submersible pumps, well digging, water treatment plants, and current Ghana borehole prices (blog estimates only; ask licensed drillers for written quotes).
Every source used in this manual is listed, with links, in the Teacher Copy.