Test part by part, repair the board, understand the power supply, and be honest about what is worth mending. Safe, systematic and paid work.

A soldering iron, a circuit board and a multimeter on a repair bench A bench with a blue circuit board in the middle holding a few small parts. A soldering iron rests on the board with a small curl of smoke rising. To the left a digital multimeter with a round dial and two probes. To the right a small radio with an antenna and a hand-held torch ready to be mended. 4.7 TEST FIRSTSOLDER NEATLYMEND AND SELL
Trainee name
Training centre
Start date
Instructor
Prepared by De-Graft Afful · Version 1.1.0 · November 2026
01

About this module

At Level 1 you mended things that run on batteries. At Level 2 you go deeper: you test every kind of part, you repair boards, and you meet the power supplies that sit between the wall and the device. This is also where the danger rises, so safety comes first again.

Who it is for. Trainees who have completed Electronics Repair and Soldering (Level 1) or who can show the same skills: safe soldering, multimeter use and low-voltage fault finding. Aged 18 or over. National Proficiency II continues to National Certificate I in the national framework.

CTVET status. Electronics competency-based courses were listed at NP I and NP II with dates that ended in April 2025, so current accreditation is not verified. The unit list was not found, so this module is not that curriculum. Ask CTVET or the regional TVET Service office for the current standard.

Bridge from Level 1: what you already know

  • Low voltage only; never open mains items without the rules in this module
  • Solder fume, lead and burn safety
  • Resistor codes, multimeter voltage, resistance and continuity
  • Ten good solder joints and desoldering
  • The fault-finding order: ask, look, power, path, fix one thing, record
  • Mend, refer or refuse
  • Pricing with cost and mark-up

How the module works

Each unit has learning outcomes, performance criteria, a range and evidence. You are judged Competent or Not Yet Competent by being watched at work, by your repairs, by answering questions and by your logbook. Each unit ends with homework and Check yourself, and the module ends with a 12-question quiz.

02

Unit 1 · Bridge and the safe bench

At Level 1 the safe rule was "no mains". At Level 2 the rule becomes a ladder, with clear steps and clear stop signs. Stay on the step you are cleared for.

Competency standard

Learning outcome Performance criteria — the trainee…
1.1 Use the permission ladder classes every item as Tier A, B or C before touching it
1.2 Isolate and test dead unplugs, removes batteries, waits, discharges and confirms with a meter
1.3 Control static and fume repeats the Level 1 controls; chooses when a wrist strap is not allowed
1.4 Handle e-waste sorts and stores waste and batteries properly
1.5 Report and refer records dangerous finds and refers them

Range. All workshop work. Evidence. Observation every session; oral questions; set-up check sheet.

Ask a qualified expert. Mains-powered equipment can kill. For electrical work, ask an Energy Commission-certified electrician or a qualified electronics technician. Never work alone on a mains-powered unit, and never power one up on your own. For burns, shocks or any injury, see a doctor or nurse; in an emergency call 112.

The permission ladder

Tier What it is What you may do
A Battery and low-voltage items (torches, radios on batteries, leads, power banks from the outside) Test, mend and solder on your own, after Level 1 rules
B Mains-powered items such as small radios, amplifiers and power-supply boards Only unplugged, discharged, with a qualified technician present: look, test components with the meter on power-off ranges, replace parts. No powered tests by trainees.
C Never for trainees: live mains testing, CRT televisions and monitors, microwave ovens, anything with a high-voltage tube or capacitor-charged unit you do not understand, wall wiring, plugs on building circuits Refuse and refer

Indoor wiring may legally be done only by Certified Electrical Wiring Professionals under L.I. 2008. Powered testing of a mains unit is the job of a qualified technician or a certified electrician, never a trainee alone.

Stop sign. If you are unsure which tier an item is in, it is a higher tier than you think. Stop and ask.

Isolate, wait, discharge, test dead

  1. Unplug the unit from the wall socket. Do not rely on the switch. Remove batteries if it has them.
  2. Wait. Big capacitors can store a dangerous charge after unplugging.
  3. Discharge the large capacitors in the power part under supervision. Common advice in foreign repair guides is to place a resistor across the capacitor, for example 4.7 kΩ at 10 W for capacitors up to about 600 V DC, and never a screwdriver; the guides differ on values, so follow the service manual for the unit when you have one. The qualified technician chooses the value and does the discharge.
  4. Confirm dead with the meter on DC volts across the capacitor. It must read close to zero before you touch the board. Check twice.
  5. Test dead. Use the meter only on power-off ranges: resistance, continuity, diode test.
  6. Never power a repaired unit up alone. The qualified person does the first power-up, with an isolation transformer where appropriate.
  7. Record the steps in your logbook.

Capacitor discharge tool

Capacitor discharge tool (resistor with insulated leads) with every part numbered A power resistor in an insulating holder with two insulated leads and clips connected to the terminals of a large capacitor, and a multimeter beside it confirming zero volts. capacitor 0.0 V meter: confirm dead 1 2 3 4 5 6 7 Parts (numbers match the drawing) 1 Capacitor being discharged 2 Power resistor (value and watts set by the qualified technician) 3 Insulated holder and handle 4 Insulated lead 5 Insulated clip on the terminal 6 Second clip on the other terminal 7 Meter on DC volts: confirm dead
A discharge tool: a power resistor in an insulated holder with insulated leads and clips, joined to the capacitor terminals. A meter then confirms zero volts. The qualified technician chooses the resistor. Source: author's drawing; RepairFAQ Safety.
No. Part What it does Safety rule
1 Capacitor being discharged Holds stored charge after unplugging Treat as live until the meter says otherwise
2 Power resistor Turns the stored energy into heat slowly; value and watts are chosen from the service manual by the qualified technician A resistor that is too small in watts can burn; a screwdriver is never used
3 Insulated holder and handle Keeps your hand away from the leads Hold only the insulated part
4 Insulated lead Joins resistor to clip Replace if the insulation is cracked
5 First clip Grips one capacitor terminal Clip on with the unit dead; never touch the bare clip
6 Second clip Grips the other terminal Both clips on before you wait
7 Meter on DC volts Confirms the voltage has fallen to near zero Check twice

How long does it take? A capacitor discharges through a resistor with a time constant of R times C. Worked example (example numbers, checked by script): a 220 microfarad capacitor charged to 400 V with a 4.7 kilohm resistor has a time constant of 4.7 k x 220 uF = 1.03 s. It falls to 50 V in about 2.2 s and to 5 V in about 4.5 s. The stored energy is half x C x V squared = 17.6 joules, and the resistor starts at V squared over R, about 34 W for a moment. This is why the resistor must be chosen by a qualified person; sources differ on values. Without a resistor, a 10 megohm meter alone takes a very long time (a time constant of about 2,200 s), so never rely on the meter to drain it.

SAFETY PROTOCOL: discharging a capacitor (Tier B, qualified technician present) Before you start. Unplug the unit from the wall and remove batteries. Wait. Put on safety glasses. Stand on a dry floor with an insulating mat. Keep one hand behind your back. Have the qualified technician approve the resistor value and watts. While you work. Clip on the insulated leads with the resistor already in the loop. Hold for the time the technician states. Never use a screwdriver, never short with wire, never touch the terminals. Confirm with the meter on DC volts across the capacitor: it must read close to zero. Check twice. After. Remove the leads. Write the voltage reading and time in the logbook and job card. Only then start the dead tests. Keep the discharge tool clean and dry. Emergency. A spark, pop or shock: stop, step back, keep others away, switch off at the wall if it is safe to reach, and call your trainer. Call 112 for a serious shock, burn or fire. Do not touch a person still in contact with mains: switch off at the source first. Ask a qualified expert. A qualified electronics technician or electrical engineer must approve every discharge instruction before you do it. For any shock, see a doctor or nurse.

Static and fume, again

  • Static can damage small parts without a spark you feel. Unplug, ground the work surface, and use a wrist strap with its built-in resistor where the unit is battery or low voltage.
  • Do not wear a wrist strap on a mains power supply or a CRT. On such boards, touch earth before you start and then work with one hand where you can.
  • Control solder fume as before: move fume away from the face; extraction is better than a mask. Wash hands before eating.

Low-voltage, mains and the law

Ghana's Energy Commission only allows certified electricians for indoor wiring. Appliance rules also apply to what is sold: the Commission's standards and labelling regime regulates imports of electrical appliances; the current position on imports from December 2025 was not verified. Do not give advice on legal sales of appliances; refer to the Energy Commission or the Ghana Standards Authority.

Which tier?

Your trainer shows ten items. Say Tier A, B or C and what you may do.

Isolate and confirm dead (supervised)

  1. With a qualified technician present, unplug a scrap mains-powered amplifier and place it on a heat-proof mat.
  2. Wait at least five minutes, then open the case.
  3. Identify the large capacitors in the power section.
  4. The technician discharges them with the discharge resistor.
  5. You measure DC volts across each capacitor and read the meter aloud.
  6. Write the readings in your logbook. Close the unit.

Tier list

List 10 items in your home or on your street and give each a tier. Write one rule you will follow for each tier.

Check yourself

  1. Why unplug and not just switch off?
  2. Which tools never discharge a capacitor?
  3. Who does the first power-up of a repaired mains unit?
03

Unit 2 · Test components in depth

A board is just parts joined together. Test each part the right way and the faulty one will stand out.

Competency standard

Learning outcome Performance criteria — the trainee…
2.1 Test resistors and fuses measures out of circuit and compares with the colour code
2.2 Test capacitors identifies bulged or leaking capacitors; measures capacitance where the meter allows
2.3 Test diodes and LEDs uses the diode range to find the forward and reverse readings
2.4 Test transistors tests a simple transistor as two diodes
2.5 Test coils, switches and speakers measures continuity and resistance and judges the result
2.6 Test in and out of circuit explains why in-circuit readings can mislead

Range. Loose parts and low-voltage boards; Tier B boards only with a supervisor and dead. Evidence. Observation; test table in the logbook.

Ask a qualified expert. Test only dead boards. For mains-powered boards, a qualified technician must be present; for building wiring, ask an Energy Commission-certified electrician. For injury, see a doctor or nurse.

Tools and items for this unit

Item What it is and what it does Size or type Also called Tier Safety rule
True-RMS multimeter A meter that reads the heating value of a changing signal correctly Hand-held true RMS DMM A for batteries; Tier B for dead tests Cheap average-reading meters misread some inverter waveforms
Capacitor ESR meter Measures the hidden resistance of a capacitor; a high ESR means a tired capacitor Hand-held or pocket ESR tester B Discharge the capacitor first; compare with a known-good part, not a made-up number
LCR meter Measures inductance (L), capacitance (C) and resistance (R) Bench or hand-held LCR bridge B Dead parts only
Component tester A small meter that finds the type and legs of a transistor, diode or capacitor Pocket transistor tester B Discharge the part first
Clamp meter Measures current by clamping round one wire Hand-held tong tester C for mains work Mains current is for a qualified person
USB power meter A small plug that shows volts and amps passing Inline USB USB tester A Use on USB ports only
Infrared thermometer Reads the surface temperature from a distance Pocket IR gun A Do not point at eyes
Hydrometer Reads the density of the acid in a flooded lead-acid cell Squeeze bulb acid tester B Acid and gloves: ask the supplier
Battery capacity tester Discharges a battery into a known load to measure how much it holds Bench battery load tester B Do not use on swollen batteries

SAFETY PROTOCOL: test instruments in general Before you start. Know the tier of the item and have the qualified person present for Tier B. Check the instrument's leads and case. Set the instrument to the right function and range before touching the circuit. Read the manual for the exact meter. While you work. Instruments go on dead items unless the supervisor says otherwise. Keep one hand away from the circuit. Never exceed the instrument's rating; the safety category (CAT) is the maker's claim for the place it is used. Do not use a damaged instrument. After. Switch off, remove leads, store dry. Record readings. Emergency. Shock, burn, smoke: switch off at the source, keep others away, call your trainer; call 112 for a serious injury. Ask a qualified expert. For mains measurements, ask a qualified electrician; for injury, see a doctor or nurse.

Out of circuit and in circuit

A part is out of circuit when one leg is lifted or the part is removed. Other parts around it can change the reading when it is in circuit. A resistor read in circuit may read lower than its true value because other paths run in parallel. For a sure reading, lift one leg.

The tests

Part Meter setting Good reading Bad sign
Resistor Ω Close to the colour code (within tolerance) Much higher, or open (OL)
Fuse Continuity Beep No beep
Switch Continuity Beep when closed; none when open No change
Coil or speaker Ω Low value, a few ohms for a speaker Open (OL)
Diode Diode test One direction shows about 0.5 to 0.7 V (silicon); other shows OL Both directions beep or both OL
LED Diode test May light faintly; one direction Both OL
Electrolytic capacitor Capacitance (if available), or visual Close to marked value; flat top Bulged top, leaking, no reading
Transistor Diode test Like two diodes joined Reading in both directions between two pins

The silicon diode reading of about 0.5 to 0.7 V is a typical foreign teaching value; your meter may show a different number, so compare with a known good part.

Capacitors

  • An electrolytic capacitor has a plus and a minus leg. The minus is marked by a stripe. Fit it the right way.
  • A bulged top, leaking brown fluid, or a cracked case means the capacitor has failed. Replace it with one of the same capacitance and a voltage rating equal or higher (not lower), and the same or higher temperature rating where marked.
  • Capacitors in power supplies can store charge: discharge before testing (Unit 1).
  • A capacitor can fail without looking bad. If you have a capacitance meter, measure it out of circuit and compare with the marking.
Aluminium electrolytic capacitor, good and bulged, with every part numbered An upright electrolytic capacitor with sleeve, minus stripe, scored vent top, rubber seal and two leads, next to a bulged failing capacitor. - bulged top: replace 1 2 3 4 5 6 7 Parts (numbers match the drawing) 1 Aluminium can with plastic sleeve 2 Minus stripe (negative side) 3 Scored vent on top 4 Rubber seal at the base 5 Longer lead: plus (new part) 6 Shorter lead: minus 7 Bulged top: faulty, replace
An electrolytic capacitor and a failing one. A bulged top means the part has failed. Source: author's drawing.
No. Part What it does Safety rule
1 Aluminium can with sleeve Holds the foil and liquid; the sleeve prints the value and voltage Never fit a lower-voltage part than the original
2 Minus stripe Marks the negative leg Wrong polarity can heat and burst the part
3 Scored vent Opens safely if pressure builds Keep your face away from a bulged one
4 Rubber seal Closes the base Leaking brown fluid means failure
5 Longer lead Plus on a new part Use the stripe if legs were trimmed
6 Shorter lead Minus
7 Bulged top A failed capacitor Replace with the same value and voltage, or higher voltage and the same size

Ask a qualified expert. A capacitor can hold a charge: discharge by the method above, with a qualified technician present, before touching it.

Diodes and LEDs

  1. Set the meter to the diode symbol.
  2. Touch the red probe to the anode (the end without the stripe) and the black probe to the cathode (the striped end). A silicon diode shows a number such as 0.5 to 0.7. Reverse the probes: it should show OL.
  3. A diode that shows OL in both directions is open. One that shows a very low reading both ways is shorted.
  4. An LED tested this way may glow faintly; do not use this test on a circuit that is powered.

Transistors

A simple bipolar transistor has three legs: base, collector and emitter. With the meter in diode range, the base to collector and the base to emitter each behave like a diode in one direction and OL in the other. Collector to emitter should read OL both ways. A reading in both directions between two legs means a faulty transistor. Many types differ; look up the pinout in the data sheet or service manual.

Parts you will meet on boards

Part Mark Remark
Resistor Colour bands or number Surface mount has numbers: 103 means 10 followed by three zeros = 10 kΩ
Capacitor Value and voltage Electrolytics have a stripe
Diode Black band Check direction
Transistor Three legs Look up the pinout
Regulator Three legs, numbered Gives a steady voltage
Chip (IC) Rows of legs Mark pin 1 before removing

Read and decide

  1. A resistor marked brown, black, red, gold measures 1,050 Ω in circuit but 1,000 Ω with one leg lifted. Is it good?
  2. A 1,000 µF 16 V electrolytic with a bulged top. Replace with a 1,000 µF 10 V one?
  3. A diode reads OL in both directions. Good or bad?
  4. A surface-mount resistor is marked 472. Value?

Component test table

  1. Collect 10 parts (resistors, diodes, capacitors, a fuse, a speaker, a switch, an LED).
  2. For each, choose the meter setting and test. Write the reading.
  3. Mark each part Good or Bad with a reason.
  4. Test a resistor in circuit on a practice board, then lift one leg and test again. Note the difference.
  5. Check the polarity marks on three electrolytic capacitors.
  6. Keep the table in your logbook.

Bulged capacitors

Ask permission and look at three old devices (not plugged in and not opened if mains; look from the outside where you can see). List what bulged or burnt parts you find. Do not open anything that plugs into the wall.

Check yourself

  1. Why lift one leg of a part for a sure reading?
  2. What replacement voltage rating is allowed for a capacitor?
  3. What does OL in both directions on a diode mean?
04

Unit 3 · Better soldering and board repair

Good soldering is a skill. Board repair is the same skill with patience: you rebuild what the board has lost.

Competency standard

Learning outcome Performance criteria — the trainee…
3.1 Choose temperature and tip sets the iron for the solder in use and the part size
3.2 Replace parts on a board desolders and fits through-hole parts without damaging tracks
3.3 Repair a lifted pad or broken track makes a wire link or repairs the track
3.4 Fix a cracked joint re-solders suspect joints in connectors and large parts
3.5 Take a first look at SMD identifies SMD parts and places one with tweezers under supervision

Range. Through-hole parts on dead boards; first look at SMD. Evidence. Observation; repaired boards.

Ask a qualified expert. Solder fume and lead need control: if you cough or wheeze, see a doctor or nurse. Mains-powered boards need a qualified technician (Tier B). Ask an Energy Commission-certified electrician for any building wiring.

Temperature

Leaded solder melts at about 183 °C and lead-free SAC305 at about 217 to 220 °C. Foreign guides suggest iron settings of about 315 to 370 °C for leaded and about 340 to 400 °C for lead-free, and they differ. A good rule: set the iron about 50 to 150 °C above the melting point, and use the lowest temperature that gives a joint in two to three seconds.

  • Large pads and big parts take heat away and need a higher setting or a bigger tip.
  • Small parts and thin tracks need lower heat and a fine tip to avoid lifting.
  • A tip that has gone black will not pass heat. Clean and tin it, or replace it.

Alloys, flux and tips

Alloy Melting Note
Sn63Pb37 (leaded) about 183 C Easy to use; contains lead: wash hands
SAC305 (lead-free, tin silver copper) about 217 to 220 C Harder to work; joints may look duller; judge by wetting and shape, not shine
Flux type Use Clean after?
Rosin core in the wire General hand work Usually wipe the residue with isopropyl alcohol
No-clean flux Rework where cleaning is hard Can stay if the maker says so
Water-soluble flux Production work Must be cleaned off completely
Paste or pen flux SMD and desoldering Clean with alcohol

IPC J-STD-001 is the international process standard for soldering and IPC-A-610 is the acceptance standard; IPC-7711 and IPC-7721 cover rework and repair. Check the current edition letters on ipc.org; the standards are copyrighted: this book summarises and never reproduces them.

Flux and cleaning

  • Add a little extra flux (a flux pen) on old or oxidised joints to help the solder flow.
  • After soldering, clean away flux residue with isopropyl alcohol and a brush, in an airy place, away from the hot iron.

Replace a part on a board

  1. Photograph or draw the board before you remove anything, and mark the direction of diodes, capacitors and chips.
  2. Heat each leg and remove the solder with the pump or braid. If the part is stuck, add fresh solder first, which helps the old solder to flow, then remove.
  3. Lift the part gently. Do not pull.
  4. Clean the holes with braid or by heating and pushing a pin through.
  5. Fit the new part the right way, solder each leg, trim.
  6. Re-inspect with a magnifier. Clean with alcohol.

Repair a lifted pad or broken track

  1. Look closely with the magnifier. Find where the copper is broken or lifted. Check with the meter on continuity that it really is open.
  2. Scrape a little of the green coating from each side of the break to show clean copper.
  3. Tin both clean spots.
  4. Lay a short piece of thin enamelled wire across the break and solder each end to the exposed copper.
  5. Check continuity across the repair. Glue the wire down with a dot of adhesive to stop it lifting.
  6. Test the board.

Cracked joints

Connectors, heavy parts and parts that heat up (such as power resistors and transformers) can crack their joints with heat and movement. They look like a thin dark ring around the leg. Re-solder them with fresh solder and a little flux. This often cures intermittent faults.

Surface-mount chip sizes drawn to the same scale with every part numbered Four chip resistor bodies drawn to scale: 1206, 0805, 0603 and 0402 with metal end caps, and two copper pads below. 1206 (3.2 x 1.60 mm) 0805 (2.0 x 1.25 mm) 0603 (1.6 x 0.80 mm) 0402 (1.0 x 0.50 mm) pads on the board 3-digit code on top: 103 = 10 k, 4R7 = 4.7 ohm 1 2 3 4 5 6 7 Parts (numbers match the drawing) 1 1206 chip (largest) 2 0805 chip 3 0603 chip 4 0402 chip (very small) 5 End cap (solder joins here) 6 Pad on the board 7 Printed code (on larger chips only)
Typical chip sizes, drawn to the same scale. Imperial size codes shown; metric codes mean different sizes. Check the data sheet. Source: author's drawing; Vishay SMD Marking.
No. Part What it does Safety or care rule
1 1206 chip (about 3.2 x 1.6 mm) Largest common size; easiest to hand-solder Use a conical or small chisel tip
2 0805 chip (about 2.0 x 1.25 mm) Common on repair boards Use tweezers, not fingers
3 0603 chip (about 1.6 x 0.8 mm) Small; may lose code printing Use a magnifier
4 0402 chip (about 1.0 x 0.5 mm) Very small; easy to lose Work over a tray; beyond Tier A skills
5 End cap The metal end where solder joins Heat quickly; long heat cracks the part
6 Pad on the board The copper the chip sits on Do not lift pads: gentle heat
7 Printed code 3-digit codes on larger chips (see Appendix A3) Measure if unreadable

A first look at surface-mount (SMD)

SMD parts sit on the surface and have no legs through the board. They are small and need good light, a magnifier and tweezers. Under supervision: tin one pad, hold the part with tweezers, touch the tin to the part's end, then solder the other end. Remove by heating both ends together with the iron and sliding the part off. Leave hot-air work for Level 3.

What went wrong?

Each case below shows a result. Say the likely cause and the fix. (1) Pad lifted off the board. (2) Joint dull with a thin dark ring. (3) A new capacitor bulges after switching on. (4) Solder will not stick to a leg.

Rebuild a scrap board

  1. Take a scrap board with several parts. Photograph it and mark polarities.
  2. Remove five parts with the pump or braid. Clean the holes.
  3. Refit them correctly and solder. Check each with the magnifier.
  4. Make a deliberate break in a track on a practice board, and repair it with a wire link. Test continuity.
  5. Re-solder three suspect joints on a heavy part.
  6. Under supervision, place and solder one SMD part on a practice board.
  7. Record the settings and results.

Joint library

Make a card showing a good joint, a dry joint, a cracked joint and a bridge, with a drawing and a one-line note on each.

Check yourself

  1. What do you do before removing a part from a board?
  2. How do you repair a broken track?
  3. What is a sign of a cracked joint?
05

Unit 4 · Power supplies and chargers

A power supply turns the wall's electricity into the small steady supply that a device can use. When it fails, nothing else in the device works. Understand it and you can find most "dead" faults.

Competency standard

Learning outcome Performance criteria — the trainee…
4.1 Explain the blocks draws the blocks of a power supply and says what each does
4.2 Tell linear from switch-mode states two differences and where each is found
4.3 Test dead checks fuse, rectifier, capacitors and resistors dead under supervision
4.4 Use a bench supply sets voltage and current limit and powers a low-voltage board
4.5 Refer and report refers powered tests and sealed units

Range. Low-voltage bench supply work (Tier A); mains power sections dead and supervised (Tier B). Evidence. Observation; logbook; block drawing.

Ask a qualified expert. The input side of a power supply is mains voltage and capacitors can hold a charge after unplugging. Powered tests of mains units must be done by a qualified electronics technician or Energy Commission-certified electrician, never by a trainee alone. For shock or burns, see a doctor or nurse; for an emergency call 112.

The blocks

A simple power supply has these blocks, in order:

  1. Input and fuse: the mains comes in through a fuse that burns out if too much current flows.
  2. Transformer or switching stage: brings the voltage down (or switches it at high speed in a switch-mode supply).
  3. Rectifier: diodes that turn AC into pulsing DC.
  4. Smoothing: a big capacitor that smooths the pulses.
  5. Regulator: keeps the output voltage steady.
  6. Output: the plug or socket that goes to the device.

Linear and switch-mode

Linear Switch-mode (SMPS)
Size and weight Heavy iron transformer Small and light
Where found Old radios, some amplifiers Phone chargers, laptop adapters, TV and decoder supplies
Heat Warm, wastes energy Cooler, efficient
Repair Easier for beginners Harder; needs knowledge

Most modern chargers and adapters are switch-mode and sealed. Do not open sealed units (Tier C for trainees). Your Level 2 work is on board-level supplies in radios and amplifiers under supervision, and on bench supplies.

Switch-mode power supply block diagram with every block numbered Block diagram of a switch-mode supply: mains fuse, inrush thermistor, filter, bridge rectifier, bulk capacitor, switching transistor, controller, transformer, output rectifier, output filter and an optocoupler feedback path back to the controller. Fuse NTC Filter Bridge Bulk cap Switch Controller Transformer Out rectifier Out filter DC out Optocoupler R 1 2 3 4 5 6 7 8 9 10 11 Parts (numbers match the drawing) 1 Mains fuse 2 Inrush thermistor (NTC) 3 Mains filter (X capacitor, choke) 4 Bridge rectifier 5 Bulk (primary) capacitor: DANGER stored charge 6 Switch (MOSFET or transistor) 7 Controller chip 8 Transformer (isolates mains) 9 Output rectifier 10 Output filter capacitor 11 Optocoupler (feedback across the gap)
A switch-mode power supply as blocks. The dangerous parts are on the mains side, left. Source: author's drawing; RepairFAQ Safety.
No. Block or part What it does Safety rule
1 Mains fuse Burns out on a fault to protect the unit A blown fuse is a symptom: find the cause first; never a bigger fuse
2 Inrush thermistor Limits the first surge when switched on Can be hot; wait to cool
3 Filter (X capacitor and choke) Stops noise passing to the mains Safety-marked parts: replace with the same marked type
4 Bridge rectifier Turns mains AC into rough DC Test dead with diode range
5 Bulk capacitor Stores the rough DC; holds a dangerous charge after unplugging Discharge first
6 Switch (MOSFET or transistor) Chops the DC into fast pulses Common failure part
7 Controller chip Decides the pulse width Never guess a replacement
8 Transformer Gives the isolated low-voltage output Do not rewind
9 Output rectifier Turns pulses into DC Short diode is common
10 Output filter capacitor Smooths the output Bulged tops are a sign of failure
11 Optocoupler Sends the output-voltage report across the isolation gap Do not bridge the gap

Ask a qualified expert. Switch-mode supplies contain mains and stored charge. At Tier B you do dead tests only, with a qualified technician present. Standards such as IEC 62368-1 are why safety-marked parts must be replaced with the same marked parts.

Common faults and clues

Symptom Common causes (dead tests)
Totally dead, no light Blown fuse; failed rectifier; open resistor
Fuse blows again A short in the power section or a failed rectifier or switching part
Output low or unstable Failed smoothing capacitor (bulged or weak)
Squeal or hiccup Dried-out capacitors in the switch-mode part
Hot or burnt smell Short circuit; burnt resistor or transformer; stop and refer

Do not replace a blown fuse with a bigger one or with wire. A fuse is the safety link. A blown fuse always has a cause: find it.

Dead tests on a power-supply board (Tier B, supervised)

  1. Isolate and discharge (Unit 1). Confirm dead.
  2. Look: burnt parts, cracked solder, bulged capacitors, loose connectors.
  3. Fuse: continuity. A blown fuse suggests a short.
  4. Rectifier diodes: diode test. A short or open diode is bad.
  5. Smoothing capacitor: look and measure capacitance.
  6. Large resistors near the input: measure out of circuit.
  7. Mark what you find. Replace only parts that are clearly faulty, with the same type.
  8. The qualified person decides on a powered test.
Bench power supply (variable DC with current limit) with every part numbered Front panel of a bench power supply: voltage display, current display, voltage knob, current-limit knob, constant-voltage and constant-current lamps, output on-off button, plus and minus output terminals, an earth terminal and the power switch. 05.00 V 0.50 A + - earth 1 2 3 4 5 6 7 8 9 10 Parts (numbers match the drawing) 1 Voltage display 2 Current display 3 Voltage knob 4 Current-limit knob 5 CV lamp (green) and CC lamp (red) 6 Output on-off button 7 Plus terminal (red) 8 Minus terminal (black) 9 Earth terminal (green) 10 Mains power switch
A bench power supply with a current limit. Source: author's drawing.
No. Part What it does Safety rule
1 Voltage display Shows the set or output voltage Check before connecting
2 Current display Shows the current drawn A sudden jump means a short
3 Voltage knob Sets the output voltage Set before connecting the load
4 Current-limit knob Caps the current so a fault cannot burn the board Set low first
5 CV and CC lamps CV: voltage is regulated; CC: the limit is holding CC lit at start-up means a heavy load or a fault
6 Output on-off button Switches the output Keep off while connecting
7 Plus terminal (red) Positive output Red to plus of the circuit
8 Minus terminal (black) Negative output Never join to plus
9 Earth terminal (green) Case earth Do not use as a return
10 Mains power switch Switches the supply on Unplug to isolate

SAFETY PROTOCOL: bench power supply (Tier A) Before you start. Output off. Set the voltage and the current limit low. Check polarity. Connect leads to the item with the unit dead. While you work. Switch the output on. Watch the current display. If the CC lamp lights at once, switch off and look for a short. Do not touch bare wires. After. Output off, leads off, set the limit and voltage back to low, switch off. Emergency. Smoke or smell: switch off the output and the mains, unplug, keep away. Call 112 for fire. Ask a qualified expert. For mains parts of the supply, ask a qualified technician.

The bench power supply (Tier A)

A bench power supply gives a low, adjustable DC voltage with a current limit that protects the board.

  1. Set the output voltage to the voltage the board needs (from the label or service manual).
  2. Set the current limit low (for example 100 mA) to start. If a short exists, the supply limits the current and the board does not burn.
  3. Connect plus and minus the right way round. Switch on.
  4. If the current jumps to the limit, switch off at once and look for a short.
  5. Raise the limit slowly to the board's normal need.

Series current check. A bench supply with a current limit makes first powering of a repaired low-voltage board much safer. It does not make mains work safe.

Chargers: what you can offer

For sealed chargers and adapters you offer: test output (Level 1 rules), test the lead and plug, advise on buying a good replacement, and refer. Avoid using fake chargers; the Ghana Standards Authority has stepped up its fight against sub-standard electrical products.

Power and current

  1. A 12 V bench supply feeds a board that draws 0.5 A. What is the power in watts?
  2. If the current limit is set at 0.2 A and the board needs 0.5 A, what will happen?
  3. A fuse marked 2 A blows repeatedly. A friend suggests a 10 A fuse. What do you say?

Block drawing and bench supply

  1. Take a scrap linear power supply (unplugged and discharged, with a technician present). Draw its blocks and mark each.
  2. Find the fuse, rectifier, smoothing capacitor and regulator. Test each dead.
  3. Write whether it is linear or switch-mode and how you know.
  4. On a Tier A low-voltage board, power with the bench supply with a low current limit. Record voltage and current.
  5. Increase the limit step by step and record.

Label hunt

Look at three chargers or adapters (not opened). Write the input and output on each. Say whether it looks linear or switch-mode (heavy or light).

Check yourself

  1. Name the six blocks of a simple power supply.
  2. Why never use a bigger fuse?
  3. What does the current limit on a bench supply protect?
06

Unit 5 · Batteries, inverters and UPS

Power cuts make batteries, inverters and UPS units big business. You work on the battery side and the low-voltage side. The mains output side stays with a qualified person.

Competency standard

Learning outcome Performance criteria — the trainee…
5.1 Know battery types tells lead-acid from lithium and gives one care rule for each
5.2 Test a battery measures resting voltage and checks terminals and connections
5.3 Explain an inverter describes how a 12 V battery becomes mains AC and the difference between modified and pure sine
5.4 Do the battery-side checks checks fuse, cable size, terminals and battery before blaming the inverter
5.5 Refuse unsafe work refers mains output work and swollen batteries

Range. Battery side and 12 V wiring; small UPS units dead and supervised. Evidence. Observation; battery log; oral questions.

Ask a qualified expert. Batteries can burn and inverters produce mains voltage. For electrical work ask an Energy Commission-certified electrician; solar charge controllers and panels are covered in the Solar Energy modules and need a licensed electrician for installation. For burns or injury, see a doctor or nurse; in an emergency call 112.

Battery types

Type Where found Care rules
Lead-acid (flooded) Cars, big inverters Top up with distilled water (where it has caps); keep terminals clean; avoid deep discharge
Sealed lead-acid (AGM or gel) UPS units, small inverters No topping up; charge fully; life often 3 to 5 years in foreign guides
Lithium-ion Power banks, phones, laptops, newer inverters Never puncture, crush or open; stop using swollen cells

Lead-acid cautions. The acid can burn skin and eyes; wear gloves and glasses; wash with plenty of water. Batteries give off hydrogen gas when charging: no flame or sparks near them. Do not wear metal rings or tools across the terminals, because a short can burn you.

Test a battery

  1. Look: swelling, leaks, cracks, corrosion on the terminals.
  2. Clean the terminals with a brush and a little water (for lead-acid, wash hands afterwards).
  3. With the meter on DC volts, measure the resting voltage (no load, no charging). A healthy 12 V lead-acid battery rests at about 12.6 V full and falls as it empties (typical foreign values; compare with the battery's own label).
  4. Measure the voltage under load (a lamp). A battery that drops sharply is weak.
  5. During charging, foreign guides give about 13.5 to 14.5 V across a 12 V lead-acid battery. Treat as a guide; follow the charger's manual.
  6. Record the readings and the date.

How an inverter works

An inverter turns the DC of a battery into AC mains-type electricity. The 12 V battery feeds a switching stage and a transformer that produce 230 V AC. A modified sine output is blocky; a pure sine output is smooth. Some equipment, such as some motors and sensitive electronics, may run badly or buzz on modified sine. Ordinary meters can also misread a modified sine voltage.

A UPS (uninterruptible power supply) has a battery and an inverter, with a charger. When mains fails, it switches to the battery in a moment.

Inverter and battery side wiring with every part numbered A 12 V battery connected by thick cables with lugs through an in-line fuse to the DC input terminals of an inverter, which has cooling vents, a power switch, an AC outlet and an earth terminal. DC in switch AC out 1 2 3 4 5 6 7 8 9 10 Parts (numbers match the drawing) 1 Battery (12 V lead-acid shown) 2 Terminals and clamps 3 Battery fuse in the plus cable, close to the battery 4 Thick cable (size from the maker) 5 Lugs (crimped and tight) 6 DC input terminals (red plus, black minus) 7 Inverter body with cooling vents 8 Power switch 9 AC output socket (230 V: qualified only) 10 Earth terminal
Battery, fuse, cables and inverter. Only the battery side is yours at Tier A. Source: author's drawing.
No. Part What it does Safety rule
1 Battery Stores the energy Lead-acid gas can explode: no sparks, ventilate
2 Terminals and clamps Join cable to battery Clean and tight; never reverse
3 Fuse Burns out on a short In the plus cable close to the battery; same rating
4 Thick cable Carries the heavy current Thin cable heats: see Appendix A6
5 Lugs Crimped ends Crimped and tight; loose lugs heat
6 DC input terminals Where the battery meets the inverter Red plus, black minus
7 Body and vents Houses the electronics and the cooling Keep vents clear
8 Power switch Turns the inverter on Off before connecting
9 AC output 230 V from the inverter Not for trainees
10 Earth terminal Safety earth Qualified person only

SAFETY PROTOCOL: batteries and inverters (low-voltage side only) Before you start. Inverter off and unplugged from mains and loads. Remove rings and watches. Wear glasses and gloves. Ventilate. Keep sparks and flames away. While you work. Take off the minus clamp first and put it back last. Never lay a tool across the terminals. Do not touch the AC output. Do not open the inverter. After. Clean terminals, tighten, replace covers, record battery voltage and the fault. Emergency. A battery that is hot, bulging or leaking: stay away, ventilate, no flames. For acid on skin or eyes rinse with plenty of clean water for at least 15 minutes and see a doctor or nurse. Fire or explosion: call 112. Ask a qualified expert. For acid, burns, shocks or any injury see a doctor or nurse; for the mains side, ask a qualified electrician.

Tools and items for this unit

Item What it is and what it does Size or type Also called Safety rule
Battery terminal cleaner A small wire brush for terminal posts Pocket post brush Wear glasses
Terminal grease Stops corrosion on posts Tube petroleum jelly Thin film only
Cable lug A metal end crimped on a thick cable By cable size ring terminal Use the right crimp tool
Battery fuse A heavy fuse for the battery line Rated by the maker fuse link Same rating
Heavy crimp tool Presses a lug onto the cable Hand or hydraulic lug crimper Wear glasses
Battery hydrometer Reads density of acid in flooded cells Bulb acid tester Gloves and glasses

The battery-side checks (Tier A)

Most inverter and UPS complaints are battery side faults:

  • a flat or old battery (3 to 5 years is common for lead-acid in foreign guides),
  • loose or corroded terminals,
  • a blown battery fuse,
  • cables too thin for the current,
  • a charger fault (low or no charging voltage).

Check these first, with the inverter off and disconnected from mains and loads. Replace what is clearly at fault. If the fault points to the output (mains) side or the inside of the inverter, stop and refer to a qualified technician.

Sizing a battery for a load (example)

Current from the battery ≈ load watts ÷ (battery volts × efficiency). Usable energy is usually only about half of a lead-acid battery's rating to protect its life (example rule, not a standard).

How long will it run?

An inverter runs a 300 W load from one 12 V, 100 Ah lead-acid battery. Use an efficiency of 85% and use only half of the battery's capacity. All figures are examples. (1) What current does the battery supply? (2) How long will it run?

Battery log and inverter checks

  1. Test three batteries (look, clean, resting voltage, under load). Record.
  2. With a small inverter disconnected from mains and loads, check the battery fuse and cable ends. Note the cable size and colour (red plus, black minus).
  3. Connect the inverter to a battery with the technician's help and run a small test load (a lamp) under supervision.
  4. Measure the battery voltage with and without load.
  5. Explain, in two sentences, what you would tell a customer whose UPS gives only 5 minutes of back-up.

Power-cut survey

Ask five neighbours what they use in power cuts (UPS, inverter, torch, solar lamp). Note what fails most. Bring a one-page summary.

Check yourself

  1. Name two lead-acid battery cautions.
  2. What does an inverter do?
  3. What should you check first when a UPS gives short back-up?
07

Unit 6 · Radios, amplifiers and TVs

You do not need to know every part. You need to know the blocks and the order in which a signal travels. Then you ask where the signal stops.

Competency standard

Learning outcome Performance criteria — the trainee…
6.1 Draw the block diagram draws a radio and an audio amplifier as blocks
6.2 Find the dead block uses clues (lights, sound, picture) to say which block has failed
6.3 Mend an audio amplifier checks supply, speaker leads and output parts dead and supervised
6.4 Judge a TV fault reads standby light, sound and picture clues and refers correctly
6.5 Decide whether to mend compares repair cost and replacement cost honestly

Range. Radios and small amplifiers (Tier A or B); TVs for diagnosis from the outside and refer. Evidence. Observation; block drawings; job cards.

Ask a qualified expert. TVs and amplifiers plug into the wall and contain mains voltage and charged capacitors. Open only under supervision, dead and discharged. Never touch a CRT: refer it. For electrical work, ask an Energy Commission-certified electrician or a qualified electronics technician. For injury, see a doctor or nurse.

Blocks of a radio and an amplifier

Radio: antenna → tuner → amplifier → speaker, with a power supply feeding all of them. Audio amplifier: input → pre-amplifier (volume and tone) → power amplifier → speaker, with a power supply.

If the supply is dead, everything is dead. If one block has failed, the signal stops there. Use clues: lights on but no sound points past the supply; sound in one channel only points to that channel's amplifier or speaker.

Fault clues for audio

Symptom Likely block
Dead, no lights Power supply, fuse, switch
Lights, no sound Amplifier or speaker lead
One channel dead That channel's amplifier, a connector, or the speaker
Hum Power supply smoothing; poor earth; dry joint
Crackle when volume moves Dirty volume control (clean or replace)
Distorted sound Failed output part; wrong speaker; supply sag

Do not substitute a "close enough" part in an amplifier output. A wrong part can destroy more.

Fault finding on a small amplifier (Tier B, supervised)

  1. Isolate and discharge. Confirm dead.
  2. Open and look: burns, bulged capacitors, loose connectors.
  3. Test the speaker and its leads: continuity and ohms.
  4. Check the power supply section: fuse, rectifier, smoothing capacitor.
  5. Test visibly burnt or suspect parts out of circuit.
  6. Fit new parts of the same type. Re-solder cracked joints.
  7. Close the case. The qualified person does the first power-up.

Reading a TV from the outside

For TVs, see also the hub's Appliance and Generator Repair, which teaches fault-finding from the outside. At this level you add the block logic:

LED TV blocks: power board → main board → timing board → panel, with an LED backlight and driver.

Symptom Likely area
No standby light, nothing Power board (start there)
Standby light on, will not start Main board or its supply
Sound but dark screen Backlight circuit; a torch held to the screen shows a faint picture if the picture exists
Flicker, dim, dark patches Failing backlight LEDs

Backlight circuits can carry high voltage and the strips are often costly to replace; for many sets the cost is not worth it. CRT televisions are Tier C: refer them.

At Level 2 you diagnose and refer TVs, and you may open and test dead power boards under supervision. You do not replace backlight strips or run a TV with the cover off.

Flat-screen TV seen from the back with every board numbered Rear of an LED TV with the panel, power board, main board, timing control board, backlight strips on the edges, speakers, mains lead and the front standby light and remote sensor noted. Power Main board T-con 1 2 3 4 5 6 7 8 9 Parts (numbers match the drawing) 1 LCD panel (glass: never press) 2 Power board (mains inside: refer) 3 Main board 4 T-con (timing) board 5 Backlight LED strips (edge) 6 Speakers 7 Mains lead (unplug first) 8 Flat ribbon cables 9 Standby light and remote sensor (front)
A flat-screen TV from the back. Boards vary by brand; read the service manual for the exact model. Source: author's drawing; TVPartsToday Backlight.
No. Part What it does Safety rule
1 LCD panel The glass that shows the picture Never press; it cracks
2 Power board Makes the supplies for the other boards; has mains Refer: Tier B or C
3 Main board Receives the signal and runs the set Dead tests only
4 T-con board Sends the timing signals to the panel Do not disconnect ribbons while powered
5 Backlight LED strips Light the panel from the edge Backlight circuits can carry high voltage
6 Speakers Make the sound Disconnect before long tests
7 Mains lead Brings 230 V Unplug first
8 Ribbon cables Carry signals Do not bend sharply
9 Standby light and remote sensor Show the set is on standby and receive the remote A standby light off can mean a power-board fault

SAFETY PROTOCOL: TVs (outside view and Tier B dead checks only) Before you start. Unplug the TV. Move it face down on a soft mat. Wait. Discharge only with a qualified technician. While you work. Do not press the screen. Do not work on the power board without a qualified technician. No powered tests by trainees. After. Re-fit covers, record findings, return the item or refer it. Emergency. Burning smell or smoke: unplug if safe, leave, call 112. Do not touch anyone in contact with mains. Ask a qualified expert. For any mains work ask a qualified technician or an Energy Commission-certified electrician.

To mend or not to mend

Compare: repair cost (parts and your time), the age and value of the item, and the chance it fails again. Tell the customer honestly. A repair that costs more than half the price of a new item needs a clear reason.

Mend or not?

For each case, say which block you suspect and whether to mend. (1) An amplifier with lights but no sound; the speaker leads are intact. (2) A TV with sound but no picture. (3) A radio that crackles when you turn the volume. (4) A CRT TV that is dead.

Block drawings and a dead amplifier

  1. Draw the block diagram of a radio and an amplifier on a page.
  2. For three faults, name the block where you suspect the fault.
  3. Under supervision (Tier B), isolate and discharge a scrap amplifier. Test the speaker, the fuse, the rectifier and the smoothing capacitor.
  4. Write what you would tell the customer.
  5. For a TV demonstration unit, note the symptoms, say which board you suspect and refer; do not open.

Customer words

Write three sentences you would say to a customer whose TV has sound but no picture, to explain the fault, the cost uncertainty and your advice.

Check yourself

  1. What does "no standby light" suggest on a TV?
  2. Why must you not substitute a different part in an amplifier output?
  3. Which TVs do you refuse to open?
08

Unit 7 · Quote, guarantee and market yourself

A repair table is a small business. At Level 2 you earn more because you can do more, so your prices, guarantees and honesty must be better too.

Competency standard

Learning outcome Performance criteria — the trainee…
7.1 Choose a location and range of services picks a location and a Tier A and B service list
7.2 Quote a job prices parts, time, overhead and mark-up
7.3 Give a guarantee states a clear guarantee and what it does not cover
7.4 Break even works out the number of jobs to cover monthly costs
7.5 Market yourself and obey the law writes a profile and an advert; knows registration and e-waste basics

Range. Small repair table or shop. Evidence. Costings; marketing plan; job book.

Ask a qualified expert. Fees, tax, permits and business law change: this is general information, not legal or tax advice. Ask the Office of the Registrar of Companies, the STMA, GRA or a qualified accountant. Electrical matters go to an Energy Commission-certified electrician.

Location and services

Use the Level 1 ideas and add services you can now offer: small audio amplifiers, battery and inverter checks, power-board dead tests (supervised), TV diagnosis and referral. Keep Tier C work off your price list. For phones and computers, see the hub's Phone Repair and Computer Hardware and Networking modules.

Tools and items for this unit

Item What it is and what it does Safety rule
Quote sheet (Appendix B1) Lists parts, labour and total before work starts Customer approves in writing
Guarantee slip Says what is covered and for how long Match what you promise to what you can honour
Battery log Records tests of each battery Keep with the job card
Discharge record Records time and reading after discharge Part of the safety record

Quote a job (example)

An amplifier repair: parts GH¢40, labour 1.5 hours at an example GH¢25 an hour, overhead GH¢5.

Item Example GH¢
Parts 40.00
Labour (1.5 × 25) 37.50
Overhead 5.00
Cost 82.50
Mark-up 30% (82.50 × 0.30 = 24.75) 24.75
Price 107.25

Round to GH¢107. All numbers are examples.

Guarantee

Give a short written guarantee, for example 7 days on the repair work and the parts you fitted, and say what it does not cover: new faults, water or drop damage, and mains surges. Give the customer a receipt with the date and the fault. A guarantee builds trust, but it must be affordable: track how many jobs come back.

Break-even

Break-even is the number of jobs you must do in a month to cover your fixed costs. Fixed costs are the same each month (table or shop rent, power, data, transport). The money left from each job after parts is the contribution.

Break-even

Monthly fixed costs: rent GH¢300, power GH¢100, data GH¢50, transport GH¢150 (examples). Average job price GH¢107 and parts GH¢40 (examples). (1) What is the contribution per job? (2) How many jobs to break even?

Register and market

  • A sole proprietor's business name costs GH¢130 at the ORC in 2026, with GH¢70 a year to renew.
  • Get the Assembly's business operating permit; the fee for an electronics repair table was not verified. Register your trainees.
  • E-waste: keep it sorted; do not burn; ask the EPA about approved collectors under Act 1124. The WHO says open burning is the most hazardous e-waste practice.
  • Market with WhatsApp Business, a Google Business Profile, a clear signboard, and referrals. Show before-and-after photos with the customer's permission.
  • Keep honest: tell customers when an item is not worth mending, and refer what you may not touch.

Accessibility

Persons with disabilities can do much of this work (author's judgement). Seated bench work, a magnifier lamp, good lighting and a lower bench suit many users. Deaf trainees can do most tasks because the work is visual; use the meter's display for colour codes where colour vision is difficult. Keep the pathway to the bench clear. The Assembly's disability fund share was not verified; ask your Assembly.

Quote and plan

  1. Choose three jobs from your list and quote each with parts, labour, overhead and mark-up.
  2. Work out your monthly fixed costs and your break-even number of jobs.
  3. Write a guarantee note.
  4. Write an advert and a WhatsApp business profile.
  5. Prepare a one-page plan to show your trainer.

Return rate

Make a table with 10 imaginary jobs, 2 of which come back. What percentage came back? What does a guarantee cost you if each return costs GH¢20 of your time?

Check yourself

  1. What is break-even?
  2. Name two things a guarantee should say it does not cover.
  3. Why must you refuse Tier C jobs?
09

Glossary

Term Meaning
Anode and cathode The two ends of a diode; current flows from anode to cathode
Block diagram A drawing that shows the main parts and how the signal passes
Contribution Price minus parts cost on a job
Discharge Safely removing stored charge from a capacitor
Inverter Turns battery DC into AC
Isolate Unplug and remove all power
OL Over limit; the meter's open reading
Rectifier Turns AC into DC
SMD Surface-mount device; a part without legs through the board
SMPS Switch-mode power supply
UPS Uninterruptible power supply
Tier A, B, C The permission ladder for what you may touch
Bleeder resistor A resistor used to drain a capacitor
Bulk capacitor The big capacitor after the rectifier
ESR Equivalent series resistance of a capacitor
Optocoupler A part that passes a signal by light across a gap
Time constant R times C: the time for a capacitor to fall to about 37%
True RMS A meter reading that follows the heating value of any waveform
10

Logbook

Copy these pages into an exercise book. Your logbook is part of your assessment evidence.

  • Unit 1: tier list; isolate and discharge readings
  • Unit 2: component test table
  • Unit 3: board repair record; settings
  • Unit 4: block drawing; bench supply readings
  • Unit 5: battery log; power-cut survey
  • Unit 6: block drawings; job cards
  • Unit 7: quotes; break-even; plan
  • Every homework, dated
11

Self-check quiz

  1. Name the three tiers of the permission ladder.
  2. Who does the first power-up of a repaired mains unit?
  3. Why lift one leg of a resistor to measure it?
  4. What replacement voltage rating may a capacitor have?
  5. How do you repair a broken track?
  6. Why never use a bigger fuse?
  7. Name the six blocks of a simple power supply.
  8. What does the current limit on a bench supply do?
  9. Name two lead-acid battery cautions.
  10. What does no standby light on a TV suggest?
  11. Which TVs do you refuse to open?
  12. Cost GH¢82.50 and a 30% mark-up: what is the price?
12

Appendix A · The Technician's Handbook

Quick-look tables for the bench. Foreign values are labelled international: check them against the Ghana Standards Authority or Energy Commission text when read. Copy pinouts from the data sheet; this book does not give pinouts from memory.

Ask a qualified expert. Mains, battery, stored charge and fire risks appear in every table below. A qualified electronics technician or an Energy Commission-certified electrician must approve any mains-related work. For injury see a doctor or nurse; for fire ask the Ghana National Fire Service.

A1 · Cards from Level 1, updated

Use the Level 1 Bench Card Pack (colour code, marking, meter, battery, solder, safety). At Level 2 add: Tier card (A battery and low-voltage; B mains items, unplugged and discharged with a qualified technician, no powered tests by trainees; C never) and the Discharge record (time, resistor used, meter reading, name).

A2 · Component testing handbook

Part Out of circuit Good reading Bad reading
Resistor Ohm range Within tolerance of the colour code Open (OL) or far from the value
Fuse Continuity Beep No beep
Switch Continuity ON and OFF ON beeps; OFF does not Wrong in either position
Coil or transformer winding Ohm range A low resistance OL
Diode Diode-test range One way about 0.5 to 0.7 V for silicon (example); the other way OL Both ways low or both OL
LED Diode-test range Lights faintly in one direction Never lights, or both ways
Electrolytic capacitor Capacitance range and a look Close to the printed value; no bulge Bulged, leaking, or far below value
Transistor Diode-test between legs, or a component tester Two junctions behave like diodes (read data sheet for the leg order) Shorts or no junctions

Notes: There is no universal good ESR figure: compare with the data sheet or a known-good part; "three to five times" advice seen on forums is not verified. A Schottky diode drops less than silicon and Zener behaviour needs the data sheet. LED drop depends on colour (red about 2 V, blue and white about 3 V are example values; check the data sheet).

A3 · SMD codes

Style How to read Example
3-digit First two digits then the number of zeros 103 = 10 kilohm
4-digit (1% parts) First three digits then zeros 1002 = 10 kilohm
R as the decimal point R marks the point 4R7 = 4.7 ohm; 0R5 = 0.5 ohm
EIA-96 Two digits pick one of 96 values from a table, a letter gives the multiplier 01Y = 1 ohm (Y = x0.01); D = x1000, E = x10,000, F = x100,000

Always check the maker's marking system. A 000 or 0R0 chip is usually a zero-ohm link; measure to be sure. Chip sizes: see the SMD figure in Unit 3.

A4 · Parts you cannot guess: pinouts, packages and substitutes

Package or part What to do
TO-92 (small three-leg), TO-220 (tab), SOT-23 (tiny) Find the data sheet for the exact part number and suffix; the leg order differs between makers
Voltage regulators (78xx, 79xx, LM317 types) Read the data sheet for the pinout and the input and output voltage
Optocoupler Do not swap with a part of a different type or rating
MOSFET or IGBT Match voltage, current and package; read the data sheet

Never guess an IC. Names: American 1N and 2N, European BC and BD, Japanese 2SA, 2SB, 2SC and 2SD are naming schemes only; verify against the data sheet. Read three things on every data sheet page: absolute maximum ratings, typical values and the pinout drawing.

A5 · Power-supply reference

  • Linear supply: mains transformer, bridge rectifier, smoothing capacitor, regulator. Switch-mode supply: see the diagram in Unit 4.
  • Dead-test order: isolate, wait, discharge, confirm dead, look, fuse, bridge diodes, bulk capacitor, switch, output diodes and capacitors (Unit 4).
  • Discharge time (worked example in Unit 1): R x C is the time constant; five time constants leave under 1% of the start voltage (e^-5 = 0.67%). For 4.7 kilohm and 220 microfarad that is about 5.2 s. The qualified technician sets the resistor.
  • Bench supply start values (examples): voltage at the rated value of the board, current limit low, raise only as needed.

A6 · Battery and inverter reference

State of 12 V lead-acid, rested Approximate voltage (examples; differ by maker, type and temperature)
Full 12.6 to 12.9 V
About half 12.1 V
Flat below about 11.8 V (check the data sheet)

Rest the battery for hours after charge or load; surface charge gives a false high reading. Charging has stages (bulk, absorption, float); follow the battery maker's voltages.

Cable drop worked example (checked by script). An inverter of 1,000 W on a 12 V battery draws about 1,000 / 0.9 / 12 = 93 A (efficiency 90% assumed). Copper resistivity is about 0.0172 ohm mm2 per m at 20 C (standard physics value). For 1.5 m each way (3 m round trip): 6 mm2 gives 0.0086 ohm, a drop of 0.80 V (6.6% of 12 V) and 74 W lost as heat; 16 mm2 gives 0.0032 ohm, 0.30 V (2.5%), 28 W; 25 mm2 gives 0.0021 ohm, 0.19 V (1.6%), 18 W. So thin cable wastes power and heats: the correct size is the cable maker's ampacity table and a qualified electrician, not this example.

Runtime example. A 12 V 100 Ah battery holds 1,200 Wh. Using only half of it (to protect the battery) at 85% inverter efficiency, a 300 W load runs 1,200 x 0.5 x 0.85 / 300 = 1.7 h (example). A 12 V 7 Ah UPS battery (84 Wh) at 100 W and 85% gives about 43 min before any depth limit and about 21 min using half (example).

Waveforms. Pure sine-wave inverters suit motors, fridges and sensitive electronics; modified sine-wave ones can make some appliances run hot or noisy; check the appliance maker. A cheap average-reading meter can misread a modified sine wave.

Fault codes. UPS and inverter fault codes differ between brands: find the manual for the exact model; this book gives no code list. Use the code log in Appendix B.

A7 · Fault trees (symptom, first checks that cost nothing, test, action)

Phone or laptop charger (outside only). Dead: another socket, another lead, then refer. Hot or buzzing: unplug; refuse to open it. Slow charging: swap lead and port; a worn lead is the most common cause.

Bench or board power supply. No output: fuse, then bridge diodes, bulk capacitor, then switch part. Low or unstable output: output capacitors, optocoupler, feedback. Always dead tests only at Tier B.

UPS or inverter. Battery side first: battery voltage rested, terminals, fuse, cables, charger. If the battery side is good: refer the output side.

Audio amplifier. No sound: power rails, then speaker, then input. Hum: grounds, smoothing capacitor. Distortion: output stage; Tier B.

Radio. Dead: cells, clips, switch. Crackle: dirty control or dry joint. Weak: antenna and battery.

TV (outside view). No standby light: power board. Sound but no picture: backlight. Picture but no sound: audio part or speaker. Stop at Tier B.

A8 · Formula sheet

Formula Worked example (example numbers, checked by script) Mistake
V = I x R; P = V x I; P = I squared x R 12 V at 2 A is 24 W; 100 ohm at 12 V is 1.44 W Underrated resistor
Parallel resistors R1 x R2 / (R1 + R2) 330 ohm and 220 ohm give 132 ohm Forgetting the answer is lower
Parallel capacitors add; series capacitors C1 x C2 / (C1 + C2) 100 uF + 47 uF = 147 uF; two 100 uF in series = 50 uF Mixed up
Divider Vout = Vin x R2 / (R1 + R2) 12 V, 10 k and 4.7 k: 3.84 V Unloaded value only
RC time constant = R x C 4.7 k x 220 uF = 1.03 s Units (k and u)
Capacitor reactance Xc = 1 / (2 x pi x f x C) 100 uF at 50 Hz is about 32 ohm f in Hz
Ripple (rule of thumb) = I / (f x C) 1 A, 100 Hz ripple, 2,200 uF: about 4.5 V (a rough guide) Full-wave means twice mains frequency
Efficiency = out / in 60 W out, 75 W in = 80%; loss 15 W Forgetting the loss is heat
Transformer ratio 230 V to 12 V is a ratio of about 19:1 Mains is not for trainees
Frequency and period 50 Hz is 20 ms; 100 kHz is 10 us
Decibels Doubling voltage is 6 dB; doubling power is 3 dB
Wh from Ah 3.7 V x 2 Ah = 7.4 Wh mAh vs Ah

True RMS versus average-responding meters: the second reads some waveforms wrongly (see A6).

A9 · Standards and rules crosswalk

Rule Owner Applies to What it means at my bench Source status
L.I. 2008 Electrical Wiring Regulations Energy Commission Indoor wiring Only Certified Electrical Wiring Professionals wire buildings Official page
GS IEC 60884-2-1 and 60884-2-2 Ghana Standards Authority Household plugs and socket-outlets, import and retail from 1 Jan 2019 Fit approved plugs; BS 1363 is the listed national plug Summary only
Act 1078 (2022) Ghana Standards Authority Standards enforcement Penalties for sub-standard goods Summary only
Act 1124 (2025) EPA Hazardous and e-waste Registration, permit and eco-levy for makers and importers; repair-shop duty not verified Summary only
IPC J-STD-001, IPC-A-610, IPC-7711 and 7721 IPC (international) Soldering, acceptance, rework Process, how to judge a joint, how to rework; editions to be checked Foreign, summary only
IEC 62368-1 IEC (international) Safety of audio, video and ICT equipment Why safety-marked parts must be replaced with the same type Foreign, summary only
IEC 61010 IEC (international) Test equipment Meter safety category (CAT) Foreign, summary only
IEC 60062 IEC (international) Marking codes Colour and printed codes Listing only
ESD standards (ANSI/ESD S20.20 and IEC 61340-5-1) ESDA and IEC Static control Wrist strap, mat, common ground Not verified in this edition; ask a supplier

International standards: check against the Ghana text when read. Items marked not verified must be confirmed with the office before you print or rely on them.

Bench library (foreign, editions and prices not verified). Electronic Troubleshooting (Tomal and Widmer); Make: Electronics (Charles Platt); the data sheets and manuals for the exact items you repair.

13

Appendix B · Forms

Ask a qualified expert. Warranty and customer-data wording is a legal matter: ask a qualified lawyer. For tax, check with GRA or a qualified accountant.

B1 Quote and guarantee

Item Parts (GH¢) Labour (GH¢) Total (GH¢) Customer approves

Guarantee: covers ______ for ______ days; does not cover ______.

B2 Battery log

Date Battery and use Rested voltage Terminals Fuse Result

B3 Discharge record

Date Item Resistor used Time held Meter reading Name

B4 Fault-code log (for UPS and inverters)

Brand and model Code or light pattern Meaning from the maker's manual Action

B5 Break-even sheet

Monthly fixed cost (GH¢) Average contribution per job (GH¢) Jobs needed
fixed / contribution
14

Appendix C · The mistake catalogue (25)

Ask a qualified expert. Several mistakes below can cause shock or fire. For any mains work ask a qualified electrician; for injury see a doctor or nurse.

No. Mistake What it costs How to avoid it
1 Wrong polarity on an electrolytic Burst part Match the stripe
2 Wrong fuse (bigger) Fire Same type and rating
3 Measuring resistance live Wrong reading, damage Isolate first
4 Ohms on a charged capacitor Bad reading, meter damage Discharge first
5 Testing diodes in circuit False reading Lift one leg or compare
6 Wrong solder for the iron Poor joints Check the alloy and temperature
7 Too hot too long Lifted pads Short heat time, right tip
8 Lower-voltage capacitor fitted Failure Same or higher voltage
9 Bridging fine-pitch pins Short Flux, drag, braid
10 Using a screwdriver to discharge Burn, damaged board, shock Use a resistor tool
11 Probes across a battery on current range Blown meter fuse Dial on volts
12 Meter left on current or resistance, then measuring a battery Short Reset to OFF
13 Trusting a modified-sine reading Wrong conclusion True-RMS meter
14 Replacing parts without finding the cause Repeat failure Fault-finding order
15 Returning a job untested Complaint Final test
16 Powering a mains board up alone Shock Never; qualified person only
17 Skipping the discharge Shock Discharge and confirm
18 Same-size but lower-watt resistor Burn Watts at least as high
19 Guessing a transistor's legs Part burns Data sheet
20 Swapping an IC by guess Dead board Exact part
21 Cleaning with a flammable liquid near a hot iron Fire Iron off
22 Cutting through a swollen battery Fire Refuse
23 Thin battery cable Overheat Cable per the maker
24 No fuse near the battery Fire Fit one
25 Ignoring the customer's story Wrong fix Write it on the job card
15

Appendix D · Worked scenarios

Teaching examples written for this book, not reports of real jobs. Prices are examples.

Ask a qualified expert. Several scenarios involve mains, batteries or injury risk. For mains work ask a qualified electrician; for injury see a doctor or nurse.

  1. The charger killed by a surge. Symptom: dead. Decision: refuse to open; sell a protected replacement. Lesson: protection is cheaper than repair.
  2. The TV with no backlight. Symptom: sound but a dark screen. First clue: backlight circuit. Action: outside checks, refer the board work to the qualified technician.
  3. The inverter that does not hold. Symptom: shuts off after a minute. First checks: rested battery voltage, terminals, fuse, cable. Often a tired battery. Lesson: battery side first.
  4. The radio with a dry joint. Symptom: crackles when tapped. Fix: resolder the joint. Lesson: tap, then look.
  5. The fake-brand adapter. Symptom: warm, wrong marks. Decision: refuse; explain; tell the customer to buy a marked unit.
  6. The unsafe habit. A colleague discharges a capacitor with a screwdriver. Action: stop work, correct the method, record, tell the supervisor.
16

Appendix E · Tools and Items Glossary

Level 1 items are in the Level 1 glossary. This list adds Level 2 items. Local names differ from town to town: use the standard name and show the picture. The Also called column lists other common English or trade names.

Ask a qualified expert. Items marked mains or battery need a qualified technician or an Energy Commission-certified electrician; for injury see a doctor or nurse.

Item What it is and does Also called
Backlight strip LED strips that light an LCD panel from the edge LED bar
Battery fuse Heavy fuse on the battery lead fuse link
Bleeder resistor A resistor across a capacitor that drains it discharge resistor
Bridge rectifier Four diodes that change AC to rough DC rectifier bridge
Bulk capacitor The big capacitor after the rectifier; holds charge primary capacitor
Ceramic capacitor A small non-polar capacitor disc cap
Choke A coil that blocks noise inductor
Clamp meter Meter that measures current by clamping a wire tong tester
Component tester Pocket tester for parts transistor tester
Controller chip Chip that sets the switching of a supply PWM IC
Crystal A part that sets an exact frequency quartz
Electrolytic capacitor Polarised capacitor with high value can capacitor
ESR meter Meter for the hidden resistance of capacitors cap meter
Fast-recovery diode A diode that switches quickly
Flux pen A pen with liquid flux
Heat-sink compound Paste that passes heat to a heat sink thermal paste
Hydrometer Density meter for battery acid acid tester
Infrared thermometer Non-contact temperature reader IR gun
Inrush thermistor A part that limits the first surge NTC
Inverter Turns battery DC into AC
Isolation transformer Separates a unit from the mains earth
LCR meter Measures L, C and R
LDO and regulator A chip that gives a steady voltage 78xx type
MOSFET A fast power switch FET
Optocoupler Passes a signal across a gap by light optoisolator
Potentiometer A variable resistor volume control
Power resistor A resistor rated for high watts wirewound resistor
Relay A switch moved by a coil
Rectifier diode A diode for mains rectifiers 1N400x type
Schottky diode A diode with a low voltage drop
Series lamp A bulb in series to limit current light bulb limiter
Surge protector A strip with a part that absorbs spikes
T-con board Timing board in a TV timing control
Thermal fuse A fuse that opens on heat
Transformer Changes AC voltage by magnetism
Triac A switch for AC
UPS Battery-backed supply uninterruptible power supply
USB power meter Plug meter showing V and A USB tester
Varistor A part that clips voltage spikes MOV
Voltage stabiliser Mains tidy-up box AVR
Zener diode Holds a set voltage
17

Appendix F · Index

Look up Go to
Alloys and flux Unit 3
Batteries and inverters Unit 5; Appendix A6
Bench supply Unit 4
Capacitor discharge Unit 1; Appendix A5
Component tests Unit 2; Appendix A2
Fault trees Appendix A7
Formulas Appendix A8
Forms Appendix B
Mistakes Appendix C
SMD Unit 3; Appendix A3
Standards Appendix A9
Tiers Unit 1
TVs Unit 6
18

Further reading and sources

Best next reads: the service manual of the device you are mending; SparkFun's free multimeter tutorial; the next module, Electronics Repair and Soldering Level 3.

What this module does not cover: powered testing of mains units, CRT televisions, microwave ovens, SMD hot-air work and chip-level repair (Level 3), phones and computers, building wiring, and solar installation.

Every source used in this manual is listed, with links, in the Teacher Copy.

One application of the Cold-Start Learning Kit, which stays general-purpose and can build a guide on any topic in any field. Written in CTVET format; not CTVET's own electronics curriculum.