About this module
At this level you work with little supervision on low-voltage work, you handle problems that are not routine, you teach others, and you can run a business. With that comes more responsibility: for safety, for honest advice and for your customers' money.
Who it is for. Trainees who have completed Electronics Repair and Soldering Level 2, or who can show the same skills and who understand the permission ladder. Aged 18 or over. National Proficiency II leads to National Certificate I in the national framework. This module is an advanced module comparable to that level; it is not a CTVET curriculum and does not carry accreditation.
CTVET status. Electronics competency-based courses were listed at NP I and NP II with dates that ended in April 2025; current status is not verified. Ask CTVET or the regional TVET Service office for the current standard before you claim any qualification.
Bridge from Level 2: what you already know
- The permission ladder: Tier A alone, Tier B supervised, Tier C never
- Isolate, wait, discharge, test dead; the first power-up is not yours
- Component tests; board and track repair; first SMD look
- Power-supply blocks, linear and switch-mode; bench supply with current limit
- Battery care; inverter and UPS battery-side checks
- Radio, amplifier and TV block logic
- Quoting, guarantee, break-even
How the module works
Each unit has learning outcomes, performance criteria, a range and evidence. You are judged Competent or Not Yet Competent by being watched at work, by your repairs and records, by answering questions and by your logbook. Each unit ends with homework and Check yourself; the module ends with a 12-question quiz and a capstone.
Unit 1 · Schematics, service manuals and signal tracing
A circuit diagram is a map. A service manual is a guide who knows the road. With both, you do not guess.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 1.1 Read a schematic | names the symbols, follows the power and the signal, and marks test points |
| 1.2 Use a service manual | finds the block diagram, the part list and the test voltages for a fault |
| 1.3 Trace a signal | uses half-splitting to find the failed stage |
| 1.4 Use the scope safely | sets probe, ground and timebase correctly and reads a simple trace |
| 1.5 Record and report | writes a repair report that another technician can follow |
Range. Low-voltage boards (Tier A); mains boards dead and supervised (Tier B). Evidence. Observation; marked diagrams; repair report.
Ask a qualified expert. A scope's probe ground is connected to mains earth on many bench scopes, so clipping it to the wrong point on a live board can cause a short or danger. Never use a scope on a mains-powered unit without a qualified technician. For electrical work ask an Energy Commission-certified electrician; for injury see a doctor or nurse.
Reading a schematic
- Symbols stand for parts: a zig-zag or box for a resistor, two lines for a capacitor, a triangle with a bar for a diode, a circle with a letter for a transistor.
- Lines are wires. A dot where lines cross means joined; no dot means not joined.
- Power usually runs from top to bottom; signals usually from left to right.
- Reference marks such as R12, C5 and D3 match the printing on the board and the parts list.
- Test points (TP1, TP2) show where to measure and what you should find.
The service manual
A service manual usually has: a block diagram, the circuit diagram, a parts list with values and ratings, test voltages, and notes on adjustment and safety. Always use the manual for the model you have. Voltages and values in a different model can mislead you. Where no manual exists, draw your own diagram as you trace the board.
Half-split fault finding
- Draw the blocks from input to output.
- Pick the middle of the chain. Measure there.
- If the signal is good, the fault is after that point; if bad, before.
- Repeat on the remaining half. After three or four steps you have the stage.
- Within the stage, test the parts out of circuit.
Voltage divider (a useful circuit)
Two resistors in series divide a voltage: V out = V in × R2 ÷ (R1 + R2). Many boards use a divider to set a voltage or feed a sensor.
Divider
- A 12 V supply feeds R1 = 6.8 kΩ in series with R2 = 4.7 kΩ. What is the voltage across R2?
- R1 and R2 are both 10 kΩ with 12 V in. What is the voltage across R2?
- On the bench the voltage across R2 in question 1 measures 8 V. What could be wrong?
The oscilloscope in brief
An oscilloscope draws a graph of voltage against time. The vertical scale is volts per division; the horizontal scale is time per division.
- Most probes are 10X: set the scope channel to match, and compensate the probe with the scope's test signal before use.
- Connect the probe ground clip to a ground point close to the test point. A long ground lead can add false ringing on fast signals.
- Ground on a bench scope is earth. Clipping it to a point that is not at ground can create a short.
- For this course, use the scope on low-voltage boards on a bench supply, and on audio and logic signals. Mains-side measurements are for qualified technicians with isolation equipment.
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Screen with grid | Shows voltage (up) against time (across) | Read the volts and time settings on the screen before you read the wave |
| 2 | Volts per division knob | Sets how many volts each square stands for | Start on a high range, then reduce |
| 3 | Time per division knob | Sets how much time each square stands for | Choose slow for audio and fast for switching signals |
| 4 | Trigger level knob | Holds the picture steady by starting the sweep at the same point | A wrong trigger gives a false picture |
| 5 | Channel 1 input connector | Where the probe plugs in; its outer ring is the scope's earth | Never clip the probe ground to a live point |
| 6 | Probe cable | Carries the signal from the circuit to the scope | Do not use a cable with cracked insulation |
| 7 | Power button | Switches the scope on | Use an earthed plug and a good mains lead |
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Screen with grid | Shows voltage (up) against time (across), one square being a division | Do not leave a bright dot still on an old screen |
| 2 | Volts per division | Sets how many volts each division means | Start on a high range, then reduce |
| 3 | Time per division | Sets how much time each division means | Slow for mains-frequency or audio, fast for switching |
| 4 | Trigger level | Holds the picture steady by starting the sweep at the same point | A wrong trigger makes a false picture |
| 5 | Vertical position | Moves the trace up or down | |
| 6 | Channel 1 input | Where probe 1 plugs in; its ground is the scope's earth | Never clip the ground to a live point |
| 7 | Channel 2 input | Second probe | Both grounds are joined: never two different grounds |
| 8 | Power button | Switches on | Use an earthed plug |
| 9 | Probe compensation terminal | A small test signal to adjust the probe | Do it before first use |
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Tip | Touches the test point | Keep the tip tidy; a lost cover can slip and short pins |
| 2 | Body | Insulated holder | Hold here |
| 3 | 1X and 10X switch | Chooses no attenuation or ten times attenuation | The scope channel must be set to match |
| 4 | Cable | Carries the signal | Do not kink |
| 5 | BNC connector | Plugs into the scope | Twist to lock |
| 6 | Ground lead | Joins the probe's ground to the circuit ground | Keep it as short as possible; a long lead adds false ringing |
| 7 | Ground clip | Clips to a ground point | Never to a live point |
| 8 | Compensation adjuster | A tiny screw that matches the probe to the scope input | Use the scope's test terminal and a plastic tool |
SAFETY PROTOCOL: oscilloscope and probes Before you start. Check the scope's earthed plug and the probe's insulation. Choose the probe setting (1X or 10X) and set the channel to match. Compensate the probe on the test terminal. Know the circuit: low-voltage or isolated only. While you work. Clip the ground first, to a ground point near the test point. Touch the tip to the test point with one hand. Mains-side measurements are for qualified technicians with isolation equipment. Never float or break the scope's earth to take a mains-side reading. After. Disconnect the tip first, then the ground. Switch off. Store the cover on the tip. Record the reading and the settings. Emergency. A spark or a shock: stop, switch off at the source if safe, keep others away and call your trainer. Call 112 for a serious shock, burn or fire. Do not touch a person who is still in contact with mains. Ask a qualified expert. A qualified technician or an Energy Commission-certified electrician must approve any mains-side measurement; for injury see a doctor or nurse. Meter and probe safety categories (CAT) are the maker's claim for the place of use.
Tools and items for this unit
| Item | What it is and what it does | Size or type | Also called | Safety rule |
|---|---|---|---|---|
| Oscilloscope | Draws a graph of voltage against time | 2 channels | scope, CRO | Earthed plug; low-voltage or isolated only |
| Probe (10X) | A lead that reduces the signal by ten and loads the circuit less | Passive | scope probe | Compensate; short ground |
| Function (signal) generator | Produces test sine, square and triangle signals | Bench | signal generator | Low-voltage output only |
| Logic probe | Shows high, low or pulsing on a digital line | Pen | Low-voltage only | |
| Isolated probe | Probe built to float safely from the ground | Specialist | differential probe | Used by qualified persons |
| Service manual | The maker's document with schematic and notes | PDF or book | repair manual | Follow it |
Writing a repair report
A good report has: customer and date, the item and model, the symptom in the customer's words, the tests you did, the fault found, the parts replaced, the result, the price, and the guarantee. A report lets another technician continue your work and protects you in disputes.
Trace a fault
- Take a Tier A board with a known fault (a faulty audio stage, for example) and its diagram.
- Draw the blocks and mark the half-split points.
- Measure the supply, then the middle of the chain. Decide where the signal stops.
- Test the parts in that stage out of circuit.
- Replace the faulty part and test.
- Write a one-page repair report.
- Under supervision, practise using a scope on a low-voltage signal: compensate the probe, connect the ground close, and draw the trace.
Draw a map
Take a simple battery device (not mains) and draw its circuit diagram from what you find inside. Mark where you would measure.
Check yourself
- What is half-split fault finding?
- Why use the manual for the exact model?
- Where must the scope's probe ground clip go?
Unit 2 · Advanced repair: SMD, hot air and parts
Modern boards use small surface-mount parts. Learn to place and remove them calmly, buy parts honestly and refuse risky substitutions.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 2.1 Solder SMD parts | places and solders two-terminal and small multi-pin parts with iron and flux |
| 2.2 Use hot air | removes and refits a small part with correct temperature and airflow |
| 2.3 Know the limits | refuses BGA and reball work without proper equipment and training |
| 2.4 Source parts | buys from reliable sources, checks parts and keeps records |
| 2.5 Substitute safely | uses equal or better parts only where the specification allows |
Range. Dead low-voltage practice boards; scrap boards. Evidence. Observation; repaired boards; parts log.
Ask a qualified expert. Hot air and solder fume need extraction; see a doctor or nurse if you wheeze or cough after work. Mains-powered boards remain Tier B with a qualified technician; ask an Energy Commission-certified electrician for building wiring.
SMD with the iron
- Put a little flux on the pads. Tin one pad.
- Hold the part with tweezers in place and touch the tinned pad to fix one end.
- Solder the other end. Re-flow the first end if it is crooked.
- For multi-pin parts, tack two opposite corners, add flux, and drag solder along the pins; remove bridges with braid.
- Clean with isopropyl alcohol and inspect with a magnifier.
Hot air
Beginner guides from tool makers suggest about 260 to 350 °C at low or medium airflow for most small SMD jobs, heating gradually. Figures vary between sources and with the part, so follow the datasheet and your station's manual.
- Use a nozzle that fits the part. Keep it moving in small circles about 1 to 2 cm above the part (example guidance).
- Too much airflow blows nearby parts away. Shield or tape neighbouring plastic parts.
- Heat gradually; large boards absorb heat in copper planes.
- Lift the part with tweezers only when all the solder is shiny and moves.
- Clean and re-tin the pads, place the new part, and re-flow.
BGA (ball grid array) chips have balls under the chip, not pins. They need a reballing station and training and are not for beginners. Refuse such work unless you have the right equipment.
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Display | Shows the set temperature | Check the setting before lifting the handpiece |
| 2 | Temperature knob | Sets the air temperature | Start low and raise slowly |
| 3 | Airflow knob | Sets how strongly the air blows | High airflow blows small parts away |
| 4 | Power switch | Switches the unit | Switch off only when the nozzle has cooled; some units need a cooling cycle |
| 5 | Hose | Carries the air | Do not kink or pull |
| 6 | Handpiece | Holds the heater and the nozzle | Never point at a person |
| 7 | Nozzle | Directs the hot air at the part | Choose the size that fits the part |
| 8 | Holder stand | Where the handpiece rests | Always return it here |
SAFETY PROTOCOL: hot-air rework station Before you start. Place the station on a heat-proof surface away from paper. Wear glasses. Set the fan to blow fume away. Shield nearby plastic parts. Choose a nozzle to fit. Set temperature low and increase gradually; sources vary, so follow the datasheet and the station's manual. While you work. Keep the handpiece moving in small circles above the part, never touching it. Never point at your hand or face. Never leave a hot handpiece in your hand: use the stand. Do not heat a battery or a sealed part. After. Return the handpiece to the stand. Let the nozzle cool until the unit says it is safe. Clean flux with isopropyl alcohol. Switch off and unplug. Wash hands. Emergency. A burn: cool under running water for 10 minutes and cover it; see a doctor or nurse if large or blistered. A fire: switch off if safe, use the extinguisher you were trained on, call 112 if not under control at once. Ask a qualified expert. For burns and breathing problems see a doctor or nurse; for the right extinguisher ask the Ghana National Fire Service.
Parts and counterfeits
Fake parts are common. Typical signs: wrong or messy markings, wrong date codes, pins that look re-tinned, a capacitor in a case that is too large for its value. Many tiny ceramic capacitors carry no marking at all, so you cannot tell by eye.
- Buy from shops that give a receipt and take returns. Keep the receipt with the job record.
- Compare an unknown part with a known good one on the meter.
- Salvaged parts may be worn or old: test before using.
- In Ghana, the Ghana Standards Authority has stepped up its fight against sub-standard electrical products. Do not fit parts that you suspect are counterfeit into a customer's device.
Substitution rules
| Part | Substitution rule |
|---|---|
| Resistor | Same value; equal or higher power rating |
| Electrolytic capacitor | Same capacitance; equal or higher voltage; similar size |
| Diode, transistor, regulator | Use the exact type or a cross-reference from the data sheet |
| Fuse | Same current and voltage rating and type; never bigger |
| Safety-marked parts (in mains supplies) | Exact replacement only; by a qualified technician |
| Unknown IC | Do not guess; obtain the exact part |
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Static-dissipative mat | Drains static slowly from the parts on it | Keep clean and dry |
| 2 | Wrist strap | Keeps you at the same potential as the bench | Wear on bare skin; do not wear on a mains power supply or a CRT |
| 3 | Coiled cord with resistor | Joins the strap to the ground point; has a built-in resistor | Replace if cut; check the label |
| 4 | Common point ground | One point where the mat and the strap are joined | Connection to earth is done by a qualified electrician |
| 5 | Cord from the mat | Links the mat to the common point | |
| 6 | Board being worked | The item under repair | Keep it on the mat |
| 7 | Bench | The work surface | Keep it tidy |
SAFETY PROTOCOL: ESD bench Before you start. Unplug the unit first. Check the strap cord and the mat. Put on the strap, bare skin. While you work. Touch the mat or the board frame before touching parts. Do not wear the strap while working on a mains power supply or a CRT. Keep plastic cups, bags and clothing away from sensitive parts. After. Put sensitive parts in anti-static bags. Remove the strap by the plug. Emergency. A shock through the strap means the ground is wrong: stop, unplug and call a qualified electrician; call 112 for a serious injury. Ask a qualified expert. The earth connection of the bench is for a qualified electrician; for injury see a doctor or nurse.
ESD at advanced level
Use a wrist strap with its built-in resistor on low-voltage boards, an anti-static mat and bags. Do not wear a strap on mains-powered supplies.
Parts decisions
Decide: use, refuse or test first, and why. (1) A 1,000 µF 25 V capacitor to replace a 1,000 µF 16 V part. (2) A 5 A fuse to replace a blown 2 A fuse. (3) A transistor from a salvaged board, unmarked. (4) A BGA chip removal for a customer's laptop.
SMD and hot-air drills
- On a practice board, solder five two-terminal SMD parts with the iron.
- Solder one small multi-pin SMD part by tacking and dragging; remove any bridge.
- With hot air, remove a small part, clean the pads, and refit it. Record the temperature and airflow.
- Test each result with the meter.
- List three parts you would test before using, and how.
- Write a parts log: source, date, receipt number and job.
Spot the fake
Look at three online listings of an electronic part (do not buy). List two warning signs that the part may be fake or unsuitable.
Check yourself
- Name one rule for fuse substitution.
- What is BGA, and why refuse it without training?
- Name two signs of a fake part.
Unit 3 · Power electronics faults
Switch-mode supplies and inverters are the heart of modern electronics, and a large share of the faults. You study them so you can diagnose them, advise honestly, and do the parts of the repair that are safe for you.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 3.1 Explain a switch-mode supply | draws and names the stages, including feedback and protection |
| 3.2 Do dead tests | finds blown fuse, shorted switching part, failed capacitor, open start-up resistor under supervision |
| 3.3 Judge repair or replace | weighs repair cost, safety and re-failure risk |
| 3.4 Handle inverter and battery faults | diagnoses the battery side and the low-voltage stage and refers the mains side |
| 3.5 Respect the gate | refuses powered mains work; refers it |
Range. Low-voltage stages and battery sides (Tier A); mains-power boards dead and supervised (Tier B). Evidence. Observation; dead-test table; case reports.
Ask a qualified expert. Switch-mode supplies and inverters contain dangerous mains voltage and charged capacitors. Powered tests are for a qualified electronics technician or an Energy Commission-certified electrician; solar charge controllers and installation need a licensed electrician (see the hub's Solar Energy modules). For shock or burns, see a doctor or nurse; in an emergency call 112.
Stages of a switch-mode supply
- Input: fuse, filter, rectifier and the large primary capacitor (dangerous stored charge).
- Start-up: a high-value resistor (or a small circuit) gives the control chip its first power.
- Switching: a fast switch (transistor or MOSFET) chops the DC into pulses through a small transformer.
- Secondary: the transformer's output is rectified and smoothed to low-voltage DC outputs.
- Feedback: a part (often an optocoupler) reports the output voltage back to the control chip, which adjusts the pulses.
- Protection: over-current, over-voltage and short circuit protection stop the supply to save the device.
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Primary winding | Takes the chopped mains-side DC | Mains side: dangerous |
| 2 | Secondary winding | Gives the isolated low-voltage output | Do not bridge to the primary |
| 3 | Switch | Chops the current on and off | Common failure part |
| 4 | Controller | Adjusts the pulse width to keep the output steady | Exact replacement only |
| 5 | Current-sense resistor | Tells the controller how much current flows | A burnt one shows overload |
| 6 | Output | The low-voltage DC | |
| 7 | Optocoupler | Sends the feedback across the isolation gap by light | Bridging it removes the isolation |
| 8 | Reference chip (TL431 type) | Compares the output with a fixed reference | Read the data sheet |
Typical symptoms and dead-test clues
| Symptom | Clues to look for (dead tests, supervised) |
|---|---|
| Dead; fuse blown | Shorted switching part, shorted rectifier, shorted primary capacitor |
| Dead; fuse good | Open start-up resistor, open fuse, failed control chip |
| Output low or unstable | Weak secondary capacitors (bulged), failing optocoupler |
| Clicking or squealing (hiccup) | Dried secondary capacitors, a shorted load drawing too much; protection cycling |
| Hot parts or burnt smell | Shorts; stop and refer |
A blown fuse is a symptom, not the fault. Never fit a new fuse and switch on. Look for the cause first.
| No. | Part | What it does | Safety rule |
|---|---|---|---|
| 1 | Mains supply with a fuse or breaker | Brings power in | Fuse or breaker sized by the qualified person |
| 2 | Isolation transformer | Separates the unit under test from the mains earth so a single touch is less likely to complete a path | It does not make live parts safe to touch |
| 3 | Series lamp | A bulb that limits the current if the unit has a short; glows bright on a fault | Choose the bulb by the technician |
| 4 | Unit under test | The opened item | Only a qualified person works on it |
| 5 | Insulating mat and dry floor | Stops a path to earth through the feet | Keep dry |
SAFETY PROTOCOL: first power-up behind an isolation transformer and series lamp (qualified person only) Before you start. A qualified technician checks the set-up, fuses, and the unit for repairs. Isolate and discharge the unit as in Level 2. Make sure the area is dry and others are away. While you work. One hand only. Switch on with the series lamp in the loop. A steady bright lamp means a short: switch off and find the fault. Never remove the lamp "to see if it works". Never touch live parts. After. Switch off and unplug. Discharge again and confirm dead before you open it again. Record the test. Emergency. A shock or a smell of burning: switch off at the source, keep others away and call 112; do not touch the person until the supply is off. Ask a qualified expert. This is live work. Only a qualified electronics technician or an Energy Commission-certified electrician may do it; trainees do not. For injury see a doctor or nurse.
Repair or replace?
Decide with honesty:
- Is the cost of repair more than about half the cost of a new unit?
- Are safety-marked parts involved (the guides call for exact replacements)?
- Is there evidence of repeat failure (poor design, fake parts, surges)?
- Can the work be tested safely before the customer takes it?
If any answer is no, advise replacement and explain why.
Inverters and UPS at advanced level
Most faults come from the battery side: age, charge, terminals and fuses. Next come the low-voltage control: cooling fans, relays and the switching transistors fed from the battery. The mains output stage is for qualified people.
- A modified-sine inverter may make some equipment buzz or run poorly; a pure sine inverter suits sensitive loads.
- Lithium batteries that are swollen must be removed from service and handed in for proper disposal.
- Do not use solar charge controllers or PV wiring as practice: see the hub's Solar Energy modules and use a licensed electrician.
Case discipline
Write each case in a report: symptom, tests, causes ruled out, cause found, part replaced, test result, who powered it up, and the customer's advice.
Case decisions
Decide: repair, replace or refer, and why. (1) A sealed phone charger with a cracked case. (2) A UPS giving 5 minutes of back-up with a four-year-old battery. (3) An amplifier power supply with a blown fuse and a shorted rectifier diode. (4) A swollen lithium battery pack.
Dead-test table
- Under supervision, take a scrap switch-mode supply board, isolate and discharge, and confirm dead.
- Draw its stages from the board; mark fuse, rectifier, primary capacitor, switching part, transformer, optocoupler.
- Test each part dead and write the results in a table.
- Mark the parts you would replace and say why.
- Write a short report with your repair or replace advice.
Honest advice
Write what you would tell a customer whose power supply has failed twice in six months, in plain words, including the cost and the risk.
Check yourself
- What does the optocoupler do?
- Why is a blown fuse only a symptom?
- Who powers up a repaired mains supply?
Unit 4 · Quality, standards, e-waste and supervising
Quality is a promise you keep every time. At this level you also teach others, so your habits become theirs.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 4.1 Run a quality check | uses a final checklist before returning any item |
| 4.2 Know the rules that touch the trade | says what the Energy Commission, GSA and EPA do |
| 4.3 Handle e-waste legally | sorts, stores and hands over e-waste properly |
| 4.4 Supervise an apprentice | plans tasks by tier, checks work and records progress |
| 4.5 Handle complaints and returns | records and learns from returns |
Range. Workshop and business practice. Evidence. Checklists; apprentice record; observation.
Ask a qualified expert. Laws and fees change; this unit is general information, not legal advice. For appliance rules ask the Energy Commission or the Ghana Standards Authority; for e-waste ask the EPA; for apprentices and employment ask the Labour Department or a qualified lawyer. For electrical work ask an Energy Commission-certified electrician. For injury, see a doctor or nurse.
Tools and items for this unit
| Item | What it is and what it does | Also called | Safety rule |
|---|---|---|---|
| Tools register | List of every tool, its condition and its calibration date | tool log | Update weekly |
| Calibration sticker | Shows when an instrument was last checked | cal label | Do not use out-of-date instruments for safety tests |
| Labelled bins | Boxes for parts, e-waste, batteries | Never mix batteries with general waste | |
| Parts traceability label | A label showing which job a part came from | ||
| Torque screwdriver | A screwdriver that stops at a set tightness | Do not over-tighten plastic | |
| Fixture or jig | A holder that places a board the same way each time |
The final quality checklist
Before you return an item, check and tick:
- The fault the customer reported is fixed and the item works as it should.
- No new fault was caused (check lights, buttons, sockets).
- Solder joints are neat; flux cleaned; no loose wires or screws.
- Case closed with all screws; no sharp edges or cracked plastic.
- For battery items: battery fresh or tested; no swelling.
- For mains items: a qualified person has done the safety checks and first power-up; the item is not returned if it fails them.
- Job record complete; price agreed; guarantee note given.
- Parts removed are returned or sorted for e-waste.
The rules around the trade
- Wiring: only Certified Electrical Wiring Professionals under L.I. 2008 may do indoor wiring. A repair shop does not do wiring.
- Appliance standards: the Energy Commission's standards and labelling regime covers appliances such as lamps, air-conditioners and refrigerators, and a notice said stricter import enforcement was to apply from December 2025; the current position is not verified. Ask the Commission.
- Sub-standard goods: the GSA has said it is stepping up market enforcement under the Ghana Standards Authority Act, 2022 (Act 1078). Do not sell or recommend goods you know are sub-standard.
- E-waste: the Environmental Protection Act 2025 (Act 1124) replaced Act 917 and regulates hazardous and electronic waste; producers and importers register with the EPA and pay a levy. A fund for e-waste is set up under the Act. For a repairer: ask the EPA what is needed to handle or hand over e-waste.
- Health: the WHO says open burning of e-waste is the most hazardous practice. Greenpeace Africa reports that informal e-waste workers lack protection and urges support for repair and refurbishing. Your trade is part of the solution: repair, sort, never burn.
Supervising an apprentice
- Register the apprentice. STMA says master artisans must register their trainees.
- Write the tiers of tasks the apprentice may do: only Tier A alone at first; Tier B never without a qualified supervisor; Tier C never.
- Demonstrate, watch, check, hand over: show the task, watch them do it, check the result, then let them do it alone.
- Record what the apprentice has learned, task by task, with dates. This helps for a later test or certificate.
- Treat them fairly. Under the Labour Act a written contract is needed for employment of 6 months or more, and workers get 15 working days' paid leave. An apprentice may be covered by a separate apprenticeship agreement; ask the Labour Department or a lawyer.
- Pay. Do not underpay; the minimum wage for 2026 is GH¢21.77 a day for workers. Whether apprentice allowances count is not verified.
Your name is on the work. If an apprentice makes a mistake, you answer to the customer. Check every job before it leaves.
Complaints and returns
- Welcome returns. Write the date, the fault, the cause and what you did.
- Work out your return rate = returns ÷ jobs. A rate that rises tells you something is wrong: bad parts, rushing or an untrained apprentice.
- Replace or repair free within the guarantee and say what is not covered.
Return rate
Ama's table did 60 jobs in March and 3 came back. Each return cost her GH¢20 of time and parts (example). (1) What is her return rate? (2) What did returns cost in March?
Quality and apprentice plan
- Write a final checklist for your table.
- Check three finished repairs with it. Record any failures.
- Make a one-page apprentice plan: name, tasks by tier, who checks, dates.
- Make an e-waste box and write a rule for handing it over.
- Write a returns sheet with columns for date, item, fault, cause and cost.
Ask the EPA
Find out (by visiting the EPA Western Region office or a trusted contact) how a small repair shop should hand over e-waste. Write what you learn, or write that it could not be verified.
Check yourself
- What is the return rate formula?
- Which tier may a new apprentice work in alone?
- Why never burn cables or boards?
Unit 5 · Establish your own business
A good technician is not yet a business owner. A business needs a legal form, a place, money, a plan and people who trust you.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 5.1 Choose a legal form | compares sole proprietor, partnership, company and cooperative |
| 5.2 Register step by step | lists the bodies and fees for a business name, TIN, permit and trade licences that apply |
| 5.3 Plan premises and start-up | works out a start-up budget and chooses a good location |
| 5.4 Find finance | names three sources and their risks |
| 5.5 Write a plan and pitch | writes a one-page plan and gives a pitch |
| 5.6 Hire, insure and market | explains hiring basics, insurance and marketing channels |
Range. A small electronics repair business in the Takoradi area. Evidence. Registration checklist; start-up budget; one-page plan; pitch.
Ask a qualified expert. Fees, taxes, permits and the law change. This unit is general information, not legal, tax or financial advice. Ask the Office of the Registrar of Companies, GRA, the Sekondi-Takoradi Metropolitan Assembly (STMA), a qualified accountant or lawyer, and a bank or the Ghana Enterprises Agency before you act. Electrical work stays with an Energy Commission-certified electrician.
Choose a legal form
| Form | What it is | 2026 ORC fee | Remarks |
|---|---|---|---|
| Sole proprietor (business name) | You and the business are one; unlimited liability | GH¢130; renewal GH¢70 a year | Simplest start |
| Partnership | 2 to 20 partners; partnership agreement | GH¢270; renewal GH¢100 a year | Agreement stamped at the Lands Commission |
| Company limited by shares | A separate legal person | GH¢585 plus a 1% capital duty on stated capital; the rate as printed needs checking | At least 2 directors and a secretary; annual returns |
| Cooperative | Members own it | Not registered at ORC; organisational TIN from GRA | Department of Co-operatives route not verified |
Annual returns cost GH¢175 a year, and late filing is GH¢1,000 (1 to 4 years) or GH¢2,000 (5 years or more). For a new repair table, a business name is usually enough; a company is worth considering when you have partners, staff and larger contracts.
Registration step by step
- Search and register the business name at the ORC.
- Tax identity. An individual's Ghana Card PIN has been the TIN since 1 April 2021; companies get a TIN from GRA after ORC registration.
- Assembly business operating permit. STMA has an online portal and a fee-fixing list; the fee for an electronics repair table is not verified. Ask the STMA revenue office. Permit payment is due by 31 March in the filing calendar in the shared facts.
- Trade licences. No Energy Commission licence is needed for a repair table that does no wiring (not verified); wiring needs a certified electrician. Ask the Energy Commission if unsure. For a shop, a Ghana National Fire Service certificate may apply: not verified.
- Register your trainees.
- Tax route. A resident with only business income who is not VAT-registered may use the Modified Taxation Scheme: turnover up to GH¢20,000 pays fixed instalments; GH¢20,001 to GH¢750,000 pays 3% of turnover (the ceiling was raised from GH¢500,000 by the Income Tax (Amendment) Act 2026; GRA's own page still showed 500,000 on 8 October 2026).
- VAT. From 1 January 2026, VAT is 15% plus NHIL 2.5% and GETFund 2.5%; the registration threshold for goods is GH¢750,000; services have no turnover threshold, so a repair business that supplies taxable services should ask GRA or an accountant whether it must register within 30 days. A VAT-registered business cannot use the Modified Taxation Scheme.
- Withholding tax. Payers may withhold tax on payments to you, for example 7.5% on services above GH¢2,000 a year for some payers; ask for the certificate.
- Keep records for at least six years.
Tools and items for this unit
| Item | What it is | Safety rule |
|---|---|---|
| Fire extinguisher | Cylinder for small fires; the right type is a Ghana National Fire Service question | Know where it is; service it |
| Signboard | Tells the customer what you do and where | Check the council rules |
| Lockable cabinet | Keeps customers' items safe | Keep a register |
| Receipt printer or book | Gives proof of payment | Keep copies |
| Mobile-money record | Your account of customer payments | Reconcile weekly |
Premises and location
- Choose places with foot traffic (market, lorry station, school, shop corner) and a safe, dry, lockable space with power and light.
- Rent and power are fixed costs. Compare at least three places.
- Keep the bench away from rain, dust and children, and keep a clear fire route.
Start-up budget (example)
| Item | Example GH¢ |
|---|---|
| Soldering station | 1,000 |
| Multimeter | 250 |
| Bench power supply | 500 |
| Hand tools | 350 |
| Magnifier lamp | 150 |
| Fume extractor or fan | 150 |
| Bench equipment | 2,400 |
| Starting parts stock | 900 |
| Table, shelves and lockable box | 400 |
| Signboard | 150 |
| Business name registration | 130 |
| Start-up total | 3,980 |
| Working capital (money for the first two months) | 2,020 |
| Total capital needed | 6,000 |
All figures are examples; the 2026 name fee is from the ORC. Jiji asking prices in a November 2026 search ranged from about GH¢61 for a basic iron to about GH¢1,000 for a station, and from GH¢160 to GH¢250 for common multimeters.
Finance
| Source | Remarks |
|---|---|
| Own savings and family | Cheapest; agree terms in writing |
| Susu or VSLA | Small amounts; regular saving habit |
| Microfinance or bank loan | Interest and collateral; use a licensed lender; the policy rate was 14.00% at the Bank of Ghana |
| Ghana Enterprises Agency (GEA) programmes | Business advisory centres in Takoradi and nearby; programmes change |
| Government budget programmes | The 2026 Budget names the National Apprenticeship Programme and others; check eligibility |
| Assemblies' disability fund | Share not verified; ask your Assembly |
Take a loan only for equipment that earns money, and only an amount you can repay from profit. Compare lenders and read the contract; ask a qualified accountant or financial adviser.
Hire, insure and market
- Hire. Register workers with SSNIT: the employee pays 5.5% and the employer 13% of basic pay, a total of 18.5%. The employer pays within 14 days after month-end. Employers deduct PAYE and pay by the 15th of the next month.
- Insure. Use only an insurer licensed by the National Insurance Commission; verify at its website. Compulsory covers for a workshop are not verified.
- Market. WhatsApp Business, Google Business Profile, a clear signboard, a portfolio with before-and-after photos (with permission), referrals and honest advice.
One-page business plan and pitch
A one-page plan has: who you serve, what you offer (Tier A and B services, no Tier C), where, prices, start-up cost and capital, monthly costs, break-even number of jobs, how you will market, risks and what you ask for. Practise a two-minute pitch that covers the same points.
Accessibility
Persons with disabilities can run a repair business (author's judgement; the Persons with Disability Act 2006 protects their rights, but check the text). A seated bench, good lighting, a magnifier, simple signs, and WhatsApp for ordering suit many owners. Deaf owners can work well because the work is visual. Choose a ground-floor location. Ask the Assembly about its disability fund; the share was not verified.
Pick the form
Kojo wants to start a repair table alone with GH¢6,000. Esi and Yaw want to start together and put GH¢3,000 each. (1) Which form suits Kojo and what is the 2026 ORC fee? (2) Which suits Esi and Yaw and what is the ORC fee? (3) What must be added for Esi and Yaw's agreement?
Registration pack
- List each registration step for your business, who to ask, and the fee or "not verified".
- Make your start-up budget and capital need.
- List three sources of finance and the risk of each.
- Write a one-page business plan.
- Give a two-minute pitch to a classmate.
Visit the STMA
Visit or call the STMA revenue office (or ask a local master artisan) and find the operating permit rules for an electronics repair table. Write what you learn, or "not verified".
Check yourself
- What is the 2026 ORC fee for a business name?
- Which tax route is for small sole proprietors who are not VAT-registered?
- Who may you register with SSNIT?
Unit 6 · Accounting and bookkeeping for a repair shop
If you do not write it down, you do not own it. Keep a few honest books and you will know whether you are making money before the money runs out. This unit goes deeper than the hub's Money Skills Level 2 and the Entrepreneurial Thinking Level 2.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 6.1 Keep the books | keeps a cash book, receipts, petty cash and stock records |
| 6.2 Track debtors and creditors | records who owes you and whom you owe |
| 6.3 Make statements | prepares a simple income statement and balance sheet |
| 6.4 Cost, price and break even | prices jobs, compares margin and mark-up, and finds break-even |
| 6.5 Depreciate and reconcile | depreciates equipment; reconciles cash and MoMo monthly |
| 6.6 Run the month-end and tax records | closes the month; keeps tax records |
Range. One small repair business. Evidence. Books for a month; statements; calculations in the logbook.
Ask a qualified expert. Tax and accounting rules change. This unit is general information, not tax or accounting advice. Check with GRA or a qualified accountant before you file or pay tax, and for the SSNIT and PAYE of your workers. Free tools such as a spreadsheet are enough to begin.
The basic idea
Assets = Liabilities + Equity. Assets are what the business owns (cash, stock, equipment, money owed to it). Liabilities are what it owes. Equity is the owner's share. Debits increase assets and expenses; credits increase liabilities, capital and income. A trial balance checks that the books balance, but it is only a partial check.
Tools and items for this unit
| Item | What it is | Safety rule |
|---|---|---|
| Job-tracking software or notebook | Lists every job, status and price | Back it up |
| Sales book | Lists each sale | Match to receipts |
| Ledger | Double-entry accounts | See the worked example |
The records you keep
| Record | What goes in it |
|---|---|
| Cash book | Every cash and MoMo receipt and payment, in date order |
| Receipts and invoices | A copy of each; numbered |
| Petty cash | Small cash for tea, transport, tape; with a float and a voucher for each payment |
| Stock card | Each type of part: bought, used, left |
| Job book | Each job with fault, fix, price and guarantee |
| Debtors list | Customers who owe you, amount and date |
| Creditors list | Suppliers you owe, amount and date |
Keep records in Ghana for at least six years. Keep owner's money and business money apart: use a separate MoMo wallet or account and pay yourself a fixed amount, called drawings.
A worked example: Kofi's repair shop in March (all figures are examples)
Opening position. Kofi puts GH¢6,000 of capital into the business on 1 March. To keep the example short, assume the table, signboard and name were already paid in the start-up budget (Unit 5), and the bench equipment of GH¢2,400 is bought on 2 March.
March cash book summary.
| Item | In GH¢ | Out GH¢ |
|---|---|---|
| Capital from owner | 6,000 | |
| Bench equipment | 2,400 | |
| Parts bought for cash | 1,100 | |
| Cash sales received | 3,900 | |
| Rent | 300 | |
| Power | 80 | |
| Data | 60 | |
| Transport | 150 | |
| Advertising | 40 | |
| Apprentice allowance | 400 | |
| Drawings (Kofi's pay) | 800 | |
| Totals | 9,900 | 5,330 |
| Closing cash | 4,570 |
(9,900 − 5,330 = 4,570.)
Other facts at 31 March. Total sales for the month were GH¢4,200, of which GH¢300 is owed by a shop customer (a debtor). Parts bought in the month totalled GH¢1,400 (GH¢1,100 paid and GH¢300 owed to a supplier, a creditor). A count shows GH¢250 of parts left (closing stock). The bench equipment is depreciated over 4 years with no value left at the end.
Depreciation. (cost − salvage) ÷ useful life. (2,400 − 0) ÷ 4 = GH¢600 a year = GH¢50 a month.
Cost of parts used. Opening stock 0 + parts bought 1,400 − closing stock 250 = GH¢1,150.
Income statement for March (profit and loss).
| Line | GH¢ |
|---|---|
| Sales | 4,200 |
| Less cost of parts used | 1,150 |
| Gross profit | 3,050 |
| Rent | 300 |
| Power | 80 |
| Data | 60 |
| Transport | 150 |
| Advertising | 40 |
| Apprentice allowance | 400 |
| Depreciation | 50 |
| Total expenses | 1,080 |
| Net profit | 1,970 |
(3,050 − 1,080 = 1,970.)
Balance sheet at 31 March.
| Assets | GH¢ | Liabilities and equity | GH¢ |
|---|---|---|---|
| Cash | 4,570 | Creditors (supplier) | 300 |
| Debtors | 300 | Capital | 6,000 |
| Stock of parts | 250 | Add net profit | 1,970 |
| Equipment (2,400 − 50) | 2,350 | Less drawings | (800) |
| Owner's equity | 7,170 | ||
| Total assets | 7,470 | Total liabilities and equity | 7,470 |
The two sides agree: 4,570 + 300 + 250 + 2,350 = 7,470 and 300 + 7,170 = 7,470. Note: profit (GH¢1,970) is not the same as cash (GH¢4,570): cash includes the capital, and profit includes money not yet received and stock not yet used.
Costing, margin and mark-up
- Mark-up is a percentage of cost. Margin is a percentage of price.
- Example: cost GH¢82.50, mark-up 30% gives a price of 82.50 × 1.30 = GH¢107.25. Margin = (107.25 − 82.50) ÷ 107.25 = 24.75 ÷ 107.25 = 23.1%.
- A 30% mark-up is therefore only a 23.1% margin. Do not mix them.
Break-even
Kofi's fixed costs for March: rent 300 + power 80 + data 60 + transport 150 + advertising 40 + apprentice 400 + depreciation 50 = GH¢1,080. His gross margin is 3,050 ÷ 4,200 = 72.6%.
Break-even sales = fixed costs ÷ gross margin ratio = 1,080 ÷ 0.7262 ≈ GH¢1,487 a month. Below that he loses money; above it he profits.
Depreciation of a new hot-air station (example)
A hot-air station costs GH¢800, is expected to last 5 years and be worth GH¢100 at the end. (800 − 100) ÷ 5 = GH¢140 a year = GH¢11.67 a month.
Employee costs (example)
Ama is a paid helper on GH¢1,200 basic monthly pay (example). SSNIT: the employee pays 5.5% = GH¢66, the employer 13% = GH¢156, total 18.5% = GH¢222. PAYE on the pay after SSNIT (1,200 − 66 = 1,134): the 2026 monthly bands are the first GH¢588 at 0%, the next GH¢80 at 5%, the next GH¢100 at 10%, and the next GH¢2,900 at 17.5%. So tax = 0 + 4 + 10 + (1,134 − 768 = 366) × 0.175 = 4 + 10 + 64.05 = GH¢78.05. Ama's take-home pay is 1,200 − 66 − 78.05 = GH¢1,055.95. The employer's total cost is 1,200 + 156 = GH¢1,356. Check the current rates with GRA and SSNIT, and with a qualified accountant.
Tax records (check with GRA or an accountant)
- A sole proprietor with only business income who is not VAT-registered may use the Modified Taxation Scheme: 3% of turnover in the GH¢20,001 to GH¢750,000 band. On Kofi's March sales annualised (4,200 × 12 = GH¢50,400), 3% would be GH¢1,512 a year (example only).
- Services have no VAT turnover threshold; ask GRA whether you must register. A VAT-registered business cannot use the Modified Taxation Scheme.
- Keep every receipt, invoice and bank or MoMo statement for six years.
- Free software such as Wave and Zoho Books offers free plans with limits. A spreadsheet is enough for a table.
The month-end routine
- Total the cash book and check it against the cash in the box and the MoMo balance. Reconcile any difference (for example, a transaction fee not yet recorded).
- Count the stock and update the stock cards.
- Update the debtors and creditors lists.
- Record depreciation.
- Prepare the income statement and balance sheet.
- Pay yourself the fixed drawings; do not take extra.
- File and pay what is due (see the calendar in your plan; confirm dates with GRA and SSNIT).
- Write a one-line note: what went well, what to change.
March for Ama's table (all examples)
Ama starts with GH¢5,000 capital. In April she buys equipment GH¢1,800 (life 3 years, no salvage), parts GH¢900 for cash, and pays rent GH¢250, power GH¢70 and transport GH¢100. Sales are GH¢3,000, all in cash. Closing stock of parts is GH¢200. She takes drawings of GH¢500. (1) Cash at month end. (2) Cost of parts used. (3) Depreciation for the month. (4) Net profit. (5) Check that the balance sheet balances.
Break-even
Ama's fixed costs are rent 250, power 70, transport 100 and depreciation 50. Her gross margin is 2,300 ÷ 3,000. What is her break-even monthly sales?
Your own books for a month
- Set up a cash book, a stock card for five parts, a debtors list and a creditors list.
- Record a month of your practice jobs (real or role-played).
- Prepare an income statement and balance sheet.
- Work out break-even sales.
- Do the month-end routine and write your note.
- Ask your trainer to check that the balance sheet balances.
Margin or mark-up
Take three of your prices. For each, work out the mark-up on cost and the margin on price. Explain the difference in one sentence.
Check yourself
- What is the accounting equation?
- What is the difference between mark-up and margin?
- Why separate owner's money from business money?
Unit 7 · Grow, sustain and the capstone
A repair business grows by trust. Quality, honest prices, clear records and fair treatment of people carry you from one table to a trusted shop.
Competency standard
| Learning outcome | Performance criteria — the trainee… |
|---|---|
| 7.1 Run quality systems | uses checklists, a returns record and a customer-care routine |
| 7.2 Set a pricing strategy | sets a price list and tests it against break-even |
| 7.3 Plan growth | compares options to grow and their risk |
| 7.4 Use records for loans and contracts | prepares records a lender or client will accept |
| 7.5 Plan ethics and succession | writes a code of conduct and a simple succession note |
| 7.6 Present the capstone | presents a one-page plan and 12-month cash-flow forecast to a panel |
Range. One small repair business. Evidence. Price list; forecast; capstone presentation.
Ask a qualified expert. Growth plans involve money, tax, contracts and employment. This unit is general information, not financial, tax or legal advice. Ask a qualified accountant, a lawyer, GRA, the GEA or your bank before you act. Electrical work stays with an Energy Commission-certified electrician.
Customer care
- Greet, listen, write down the fault in the customer's words.
- Give an honest estimate and tell the customer what you cannot do (Tier C).
- Keep the customer informed. A short WhatsApp message saves a visit.
- Return the item clean and tested, and show it works.
- Ask for feedback and a referral.
Pricing strategy
Think of three levels: a basic check or fix (cheap, quick), a standard repair with a guarantee, and a premium repair with a longer guarantee or a collection service. Test every price against your break-even and your margin. Do not copy the cheapest shop; compete on trust and speed, and never cut prices below your cost.
Example price list (examples). Cable fix GH¢35; radio crackle fix GH¢50; amplifier dead-test and repair from GH¢107; battery or UPS battery-side check GH¢40; written estimate for a TV GH¢30 (credited if repaired).
Ways to grow
| Option | What it needs | Risk |
|---|---|---|
| More hours or a second bench | A trained apprentice | Quality slips |
| A second location | Rent and stock | Cash tied up |
| Selling parts and chargers (tested, reputable) | Stock money | Fake or unsold stock |
| Contracts with schools, churches, shops, farms | A written agreement and records | Late payment |
| Training apprentices | A plan and time | Your time |
| Partnering with a phone repairer, computer shop or electrician | Clear roles; refer, do not copy | Disputes |
Partner with an Energy Commission-certified electrician for wiring jobs and refer to them, rather than doing wiring yourself. Public tenders and bigger contracts usually need a tax identity, registration and clean records; ask the buyer's procurement office for the rules.
Records for loans and contracts
A lender or client wants: your registration, TIN, a few months of cash book, income statement, balance sheet, a cash-flow forecast, and proof of address. Your clean books are your best collateral. Keep records for six years. Government programmes announced in the 2026 Budget, such as the National Apprenticeship Programme, may be open to you; check eligibility with the agency.
Ethics and succession
- Do not fit fake parts, charge for work not done, or hide faults.
- Do not repair what is unsafe; refer it.
- Do not burn e-waste, and do not leave it in the street.
- Treat apprentices and customers fairly.
- Succession: write a one-page note naming who can run the table if you are sick: where the keys, books and passwords are, who holds the customers' items, and who pays suppliers. Tell a trusted person.
The 12-month cash-flow forecast
A cash-flow forecast estimates money in and out each month so you know when cash may run short.
Worked example (all figures examples). Opening cash GH¢1,000. Sales start at GH¢2,500 in month 1 and rise by GH¢250 a month, so month 12 is GH¢5,250 and the year totals GH¢46,500. Parts cost 27% of sales. Fixed cash costs are GH¢1,030 a month (rent 300, power 80, data 60, transport 150, advertising 40, apprentice 400). Drawings are GH¢800 a month. Depreciation is not a cash cost, so it is left out.
| Month | Sales | Parts (27%) | Fixed costs | Drawings | Net cash change | Closing cash |
|---|---|---|---|---|---|---|
| 1 | 2,500 | 675 | 1,030 | 800 | −5 | 995 |
| 2 | 2,750 | 742.50 | 1,030 | 800 | 177.50 | 1,172.50 |
| 3 | 3,000 | 810 | 1,030 | 800 | 360 | 1,532.50 |
(Month 1: 2,500 − 675 − 1,030 − 800 = −5; closing 1,000 − 5 = 995.) Continue the table to month 12 in your own sheet.
Forecast months 4 to 6
Using the same assumptions, work out the net cash change and the closing cash for months 4, 5 and 6, with sales of GH¢3,250, GH¢3,500 and GH¢3,750.
The capstone
You present to a panel (a repair shop owner, an accountant or GEA adviser, and a trainer):
- One-page business plan (Unit 5).
- 12-month cash-flow forecast with your own assumptions, saying which are examples and which you checked locally.
- Start-up budget and registration checklist with "not verified" items marked.
- Quality checklist, apprentice plan and e-waste plan.
- A live demonstration: a short diagnosis of a low-voltage fault with the tier rule stated.
- A five-minute pitch and answers to panel questions.
The panel uses the capstone checklist in the assessment table. The trainee is judged Competent or Not Yet Competent.
Prepare the capstone
- Finish your plan and your 12-month forecast.
- Check every figure and label examples.
- Prepare the quality checklist, apprentice plan and e-waste plan.
- Practise the pitch twice with a partner.
- Rehearse the live diagnosis.
- Hand in a folder of your books for a month.
Three questions
Write three hard questions a panel might ask you, and your honest answers.
Check yourself
- What is a cash-flow forecast for?
- Why is depreciation left out of a cash forecast?
- Name one rule of ethics for your table.
Glossary
| Term | Meaning |
|---|---|
| BGA | Ball grid array; a chip with balls under it |
| Balance sheet | A list of assets, liabilities and equity at one date |
| Break-even | Sales or jobs needed to cover fixed costs |
| Cash-flow forecast | A plan of money in and out by month |
| Creditor | Someone you owe |
| Debtor | Someone who owes you |
| Depreciation | Spreading the cost of equipment over its life |
| Drawings | Money the owner takes out of the business |
| Half-split | Test the middle of the chain to halve the search |
| Margin | Profit as a percentage of price |
| Mark-up | Profit as a percentage of cost |
| Optocoupler | A part that passes a signal by light across an isolation gap |
| Reconcile | Match your records to the bank or MoMo statement |
| Return rate | Returns divided by jobs |
| Calibration | Checking an instrument against a known reference |
| Common point ground | One point where bench ground paths join |
| Isolation transformer | A transformer that separates a unit from the mains earth |
| Series lamp | A bulb in series that limits fault current |
| Time constant | R times C |
| True RMS | A reading that follows the heating value of any waveform |
Logbook
Copy these pages into an exercise book. Your logbook is part of your assessment evidence.
- Unit 1: marked diagrams; repair report
- Unit 2: SMD and hot-air record; parts log
- Unit 3: dead-test table; case reports
- Unit 4: final checklist; apprentice plan; returns sheet
- Unit 5: registration pack; start-up budget; one-page plan
- Unit 6: one month of books; income statement; balance sheet; break-even
- Unit 7: price list; 12-month forecast; capstone folder
- Every homework, dated
Self-check quiz
- What is half-split fault finding?
- Where does the scope's probe ground clip go?
- Give one rule for substituting an electrolytic capacitor.
- Why refuse BGA work without training?
- Why is a blown fuse only a symptom?
- Who does the first power-up of a repaired mains supply?
- What is the formula for return rate?
- What is the 2026 ORC fee for a business name?
- State the accounting equation.
- Cost GH¢82.50 with a 30% mark-up: price and margin?
- Kofi's fixed costs are GH¢1,080 and his gross margin ratio is 72.6%. What are the break-even sales?
- What is depreciation for an item costing GH¢2,400 with no salvage and a 4-year life, per month?
Appendix A · The Master Technician's Reference
Look-up pages for the advanced bench. Foreign values are labelled international: check them against the Ghana Standards Authority or Energy Commission text when read. Copy pinouts and ratings from data sheets; this book does not give them from memory.
Ask a qualified expert. Mains, high voltage, stored charge, hot air, solder fume and fire risks appear below. Mains work is for qualified technicians and Energy Commission-certified electricians; for injury see a doctor or nurse; for fire ask the Ghana National Fire Service.
A1 · Schematic reading kit
- Symbols. Use the Level 1 symbol figure; add: fuse, switch, relay, transformer, optocoupler, MOSFET, regulator, ground types and connectors from the service manual's own legend.
- Motifs to find. (a) Voltage divider: two resistors from a line to ground with the output between them; Vout = Vin x R2 / (R1 + R2). Worked example (checked by script): 12 V with 10 k over 4.7 k gives 3.84 V. (b) RC filter: a resistor in series with a capacitor to ground; cut-off frequency about 1 / (2 pi R C), so 10 k with 100 nF cuts at about 159 Hz. (c) Regulator: input capacitor, regulator chip, output capacitor. (d) Feedback: output sample, reference, optocoupler, controller (see the flyback figure in Unit 3).
- Test-point log. Write each test point, the expected value from the manual, the measured value and the difference.
| Test point | Expected (manual) | Measured | Difference | Meaning |
|---|---|---|---|---|
A2 · Switch-mode reference
| Stage | What fails | Signature | Next test |
|---|---|---|---|
| Input (fuse, filter, bridge) | Fuse, bridge, thermistor | Dead, fuse blown | Diode range on the bridge |
| Bulk capacitor | Dried or shorted | Dead or hum | Capacitance, ESR vs a known-good part |
| Start-up | Open start-up resistor | Dead, fuse good | Resistance |
| Switch | Shorted | Fuse blown, switch part short | Dead test; then check the gate resistors |
| Controller | Dead chip | No pulses | Scope on the gate at a safe point |
| Secondary | Shorted rectifier or capacitor | Output low, hot | Diode range |
| Feedback | Weak optocoupler, wrong reference | Output high or hunting | Dead tests then qualified powered test |
| Protection | Latches off | Clicking, hiccup | Find the cause, not the latch |
Safe test. Powered tests only by a qualified person behind an isolation transformer and a series lamp (Unit 3). Chip families found in Ghana chargers and TV supplies are not verified: read the chip's own marking and its data sheet.
Worked formulas (checked by script). Ideal buck output duty = Vout / Vin = 5 / 12 = 41.7%. Efficiency = out / in: 60 W out from 75 W in is 80% with 15 W lost as heat. Ripple on a smoothing capacitor is about I / (f x C): 1 A, 100 Hz and 2,200 microfarads give about 4.5 V (a rough guide only). Capacitor energy is half x C x V squared: 220 microfarads at 400 V holds 17.6 J.
A3 · Scope and logic-probe reference
- 10X rule. A 10X probe divides the signal by 10: multiply the reading by 10 if the scope does not do it, and set the channel to match.
- Compensation. Touch the probe to the scope's test terminal and adjust until the square wave has square corners.
- Ground clip. Short, near the test point; the scope ground is earth.
- Typical waveforms to expect: a square wave on a switching gate; a sawtooth or ripple on a smoothing capacitor; a clean DC on a regulator output with a little ripple. Match them to the service manual; the book gives no brand-specific values.
- Measurement checklist: probe set and compensated; ground clip placed; range set; trigger set; unit is low-voltage or isolated; reading and setting written down.
- Logic probe: shows high, low and pulses on digital lines; low-voltage only.
A4 · SMD and hot-air reference
| Topic | Reference |
|---|---|
| Chip sizes | 1206, 0805, 0603 and 0402 typical sizes: see the figure in Level 2 Unit 3; check the data sheet |
| EIA-96 | Two digits and a letter; the lookup table is in the maker's document |
| Hot-air start | About 260 to 350 C at low or medium airflow, heated gradually; figures vary by source and part |
| Nozzle | The size that fits the part; keep moving 1 to 2 cm above (example guidance) |
| Pre-heat | A pre-heater or slow heat avoids thermal shock to large boards |
| Solder paste | Applied with a stencil or a fine tip; the paste maker's profile is the guide |
| Flux | Use no-clean or rosin flux; clean with isopropyl alcohol |
| IPC rework | IPC-7711 and IPC-7721 describe rework, modification and repair; edition letters to be checked on ipc.org |
| BGA | Refuse unless equipped and trained |
Rework record form
| Date | Board and part | Method (iron or hot air) | Temperature and time | Result | Name |
|---|---|---|---|---|---|
A5 · Parts and counterfeits
- Read a data sheet. Find three things: absolute maximum ratings (never exceed), typical values, and the pinout and package drawing.
- Cross-reference. Match the parameters that matter: for a transistor or MOSFET: type, voltage, current, package; for a diode: voltage, current, speed; for a regulator: output voltage and current; for an optocoupler: transfer ratio and isolation voltage.
- Counterfeit signs. Wrong or messy markings; odd date codes; re-tinned pins; a part in a case too large for its value; unmarked tiny capacitors cannot be told by eye.
- Incoming-parts log.
| Date | Part | Shop | Receipt number | Inspection result | Used in job |
|---|---|---|---|---|---|
- Supplier register (fill in from your own survey). Shop, address area, parts range, receipts given (yes or no), return policy, prices and date.
A6 · Quality system
- Final quality checklist. Use the Unit 4 checklist as a form on every job card.
- IPC class vocabulary. IPC-A-610 describes three classes by end use: Class 1 general electronics, Class 2 dedicated service electronics, Class 3 high-reliability equipment. Class is chosen by the end use, not by how the work was done. Standards are copyrighted: this book summarises and never reproduces them.
- Calibration and tools register. Record each instrument, its calibration date and who checked it.
- Complaint and return log.
| Date | Customer (private) | Item | Complaint | Cause | Action | Cost to the shop |
|---|---|---|---|---|---|---|
- Returns analysis. Return rate = returns / jobs x 100. Review each month: group by cause.
A7 · Compliance crosswalk (with "checked on" dates)
| Rule | Owner | Applies to | What it means at my bench | Source status | Checked on |
|---|---|---|---|---|---|
| L.I. 2008 | Energy Commission | Indoor wiring | Only Certified Electrical Wiring Professionals | Official page | |
| GS IEC 60884-2-1 and 2-2 | Ghana Standards Authority | Plugs and sockets | Use approved plugs | Summary only | |
| Act 1078 (2022) | Ghana Standards Authority | Standards | Penalties for sub-standard goods | Summary only | |
| Act 1124 (2025) | EPA | E-waste and hazardous waste | Permit and eco-levy rules; the rate is not found | Summary only | |
| IPC J-STD-001, IPC-A-610, IPC-7711 and 7721 | IPC (international) | Soldering, acceptance, rework | Quality language | Foreign, summary only | |
| IEC 62368-1 | IEC (international) | AV and ICT equipment safety | Exact safety parts | Foreign, summary only | |
| Fire certificate for workshops | Ghana National Fire Service | Business premises | Required for non-residential premises; steps and fees not verified | Not verified; ask GNFS | |
| Income tax and VAT | GRA | Your business | Registration, records and thresholds | See Unit 6 |
International items: check against the Ghana text when read.
E-waste route page. No Takoradi drop-off was verified: ask EPA Western Region and the STMA waste unit. A national e-waste collection drive was reported in 2025. Sorting guide: lead-acid batteries and lithium batteries go to their own tin or sand-filled boxes; fluorescent lamps and old tubes (mercury) stay whole; oil-filled capacitors stay sealed; boards and cables go to e-waste. Never burn.
A8 · Business pack
| Item | Where | What to record |
|---|---|---|
| STMA operating permit | STMA | Fee: ask and record: ______ |
| ORC registration | Office of the Registrar of Companies | Fee: ask and record: ______ |
| GRA TIN and filing | GRA | Date and reference |
| GNFS certificate | Fire Service | Fee: ask and record: ______ |
| Insurance | An insurer | Cover and cost |
| Bookkeeping | Units 6 and 7 | Month-end routine |
| Pricing sheet | Unit 7 | Mark-up and margin |
| 12-month forecast | Unit 7 | Copy the table |
Appendix B · Forms
Ask a qualified expert. Warranty, liability and customer-data wording is a legal matter: ask a qualified lawyer. For tax, check with GRA or a qualified accountant.
Use the forms in Appendix A: test-point log, rework record, incoming-parts log, complaint and return log. Add:
B1 Final quality checklist (one per job)
- Reported fault fixed and tested
- No new fault caused
- Joints neat, flux cleaned
- Case closed, screws complete
- Battery fresh or tested; not swollen
- Mains items: qualified person's safety checks signed
- Job record complete, price agreed, guarantee given
- Removed parts returned or sorted
B2 Apprentice progress log
| Date | Task | Tier | Supervisor | Result | Signature |
|---|---|---|---|---|---|
B3 Safety incident report
| Date | What happened | Injury or damage | Action taken | Prevented next time by |
|---|---|---|---|---|
Appendix C · The mistake catalogue (36)
Ask a qualified expert. Many mistakes below involve shock, fire or injury. For mains work ask a qualified technician or Energy Commission-certified electrician; for injury see a doctor or nurse.
| No. | Mistake | Cost | Avoid it by |
|---|---|---|---|
| 1 | Wrong polarity on an electrolytic | Burst part | Match the stripe |
| 2 | Wrong or bigger fuse | Fire | Same type and rating |
| 3 | Resistance measured live | Wrong reading | Isolate first |
| 4 | Ohms on a charged capacitor | Meter damage | Discharge first |
| 5 | Diodes tested in circuit | False reading | Lift a leg |
| 6 | Wrong solder for the iron | Poor joints | Match alloy and heat |
| 7 | Too hot too long | Lifted pads | Right tip, short time |
| 8 | Lower-voltage capacitor | Failure | Same or higher voltage |
| 9 | Fine-pitch bridge | Short | Flux, drag, braid |
| 10 | Screwdriver discharge | Burn, shock | Resistor tool |
| 11 | Probes across a battery on current | Blown fuse | Volts range |
| 12 | Meter left on current | Short | Reset to OFF |
| 13 | Scope ground on a live point | Short, shock | Ground to ground only |
| 14 | Modified-sine reading trusted | Wrong fix | True-RMS meter |
| 15 | Replacing without finding the cause | Repeat failure | Half-split |
| 16 | Return untested | Complaint | Final checklist |
| 17 | Powering a mains board alone | Shock | Never; qualified person |
| 18 | Skipping discharge | Shock | Discharge and confirm |
| 19 | Wrong probe setting (1X or 10X) | Wrong reading | Match the scope channel |
| 20 | Compensation skipped | Distorted waveform | Compensate first |
| 21 | Long ground lead | False ringing | Short lead |
| 22 | Safety part not exact | Hazard | Exact replacement |
| 23 | Guessing an IC | Dead board | Exact part |
| 24 | Hot-air airflow too high | Parts blown away | Low airflow, shield |
| 25 | Heat on a battery | Fire | Never |
| 26 | Cleaning with flammable liquid near a hot iron | Fire | Iron off |
| 27 | Bypassing the optocoupler gap | Lost isolation | Never |
| 28 | Cutting a swollen battery | Fire | Refuse |
| 29 | Thin battery cable | Overheat | Per cable maker |
| 30 | No fuse near the battery | Fire | Fit one |
| 31 | Counterfeit part fitted | Early failure | Buy with receipts |
| 32 | Ignoring ESD | Hidden damage | ESD bench |
| 33 | Wrist strap on a mains supply | Shock path | Do not wear |
| 34 | Working alone on a hazardous job | No help | Buddy rule |
| 35 | Not recording | Cannot trace | Job card |
| 36 | Pricing without costing | Loss | Cost and mark-up |
Appendix D · Worked scenarios
Teaching examples written for this book, not reports of real jobs. Prices are examples.
Ask a qualified expert. Several scenarios involve mains, batteries or injury risk. For mains work ask a qualified electrician; for injury see a doctor or nurse.
- The charger with a dead optocoupler. Symptom: output high, then dead. Clue: dead tests show a leaky optocoupler. Action: a qualified technician replaces it with the exact type, tests behind the isolation set-up. Lesson: feedback faults cause high outputs.
- The UPS that "does not hold". Symptom: drops out. Finding: tired battery, loose terminal. Action: battery side first. Lesson: do not blame the board.
- The LED TV with a dark screen. Symptom: sound but no picture. Finding: failed backlight strip. Decision: price the strip against a new TV; offer both.
- The counterfeit MOSFET. Symptom: new part fails again. Finding: wrong markings. Action: buy from a shop with receipts, test before fitting.
- The returned job. Symptom: back in two days. Cause: untested. Action: complaint log, free fix, final checklist added.
- The dangerous habit. An apprentice wears an ESD strap on a mains supply. Action: stop work, correct, record, discuss.
- The not worth mending. A cheap adapter is warm and unmarked. Decision: refuse, explain. Lesson: a refusal protects you and the customer.
- The price that lost money. A job priced without parts and time. Action: recost, raise the mark-up.
Appendix E · Tools and Items Glossary
This list adds the items first used at Level 3; Level 1 and Level 2 items are in their own glossaries. Local names differ from town to town: use the standard name and show the picture. The Also called column lists other common English or trade names.
Ask a qualified expert. Items marked mains, hot or battery need a qualified technician; for injury see a doctor or nurse.
| Item | What it is and does | Also called |
|---|---|---|
| Analyser (logic) | Records many digital lines at once | logic analyser |
| Anti-static bag | Bag that protects parts from static | ESD bag |
| Anti-static mat | Mat that drains static | ESD mat |
| BGA | Chip with balls under it | ball grid array |
| Borescope | Tiny camera on a cable to see into tight places | inspection camera |
| Brass wool | Tip cleaner | |
| Calibration reference | A known source to check an instrument | |
| Calibration sticker | Date label | |
| Common-mode choke | A coil that blocks noise on both lines | |
| Conformal coating | Thin varnish that protects a board | |
| Current-sense resistor | A small resistor that shows current | shunt |
| Curve tracer | Instrument that plots a part's behaviour (awareness only) | |
| Differential probe | Probe that measures between two points, floating | isolated probe |
| ESD ionizer | Device that neutralises static with ions | |
| ESD tester | Checks the strap and the mat | |
| Flux (no-clean) | Flux that may stay on the board | |
| Flux (water-soluble) | Flux that must be washed away | |
| Function generator | Test signal source | signal generator |
| Fume extractor | A fan with a filter that pulls fume away | |
| HEPA filter | A filter that traps very fine particles | |
| Hot-air station | Heater and blower for SMD work | rework station |
| IGBT | A power switch for high voltage | |
| Infrared pre-heater | A heater under the board that warms it evenly | pre-heater |
| Isolation transformer | Separates the unit from the mains earth | |
| LLC converter | A type of resonant supply (awareness only) | |
| Logic probe | Shows high, low, pulsing | |
| Micro-soldering iron | A fine iron for tiny work | |
| Microscope (stereo) | Magnifier with two eyepieces | |
| MPPT controller | Solar controller (referral only) | |
| Oscilloscope | Graph of voltage against time | scope |
| PFC controller | Chip that tidies the mains current | |
| Probe (10X) | Scope probe that reduces by 10 | |
| Series lamp | A bulb that limits current | |
| Solder paste | Tiny solder balls in flux | |
| Spectrum analyser | Shows signals by frequency (awareness only) | |
| Stencil | Metal sheet used to apply paste | |
| TL431 | A common reference chip | |
| TVS diode | A diode that clips spikes | |
| Thermal camera | Shows heat as a picture | |
| Torque screwdriver | Screwdriver with a set tightness | |
| UPS (line-interactive) | A battery-backed supply that corrects voltage | |
| UPS (online) | A supply that always runs from the battery | double-conversion UPS |
| Vacuum pick-up | A pen that lifts small parts by suction | |
| X capacitor | A safety-marked capacitor across the mains | |
| Y capacitor | A safety-marked capacitor from mains to the case or secondary |
Appendix F · Standards and bench library
Ask a qualified expert. Standards are not a substitute for a qualified engineer's advice. Ask a qualified technician or an Energy Commission-certified electrician before you rely on any of them.
International standards used here (summaries only; check against the Ghana text): IPC J-STD-001, IPC-A-610, IPC-7711 and IPC-7721; IEC 62368-1; IEC 61010. Books (foreign; editions and prices not verified): Electronic Troubleshooting (Tomal and Widmer); Electronic Troubleshooting and Repair Handbook (Homer Davidson); Make: Electronics (Charles Platt); Troubleshooting Analog Circuits (Bob Pease). Free: SparkFun and iFixit guides.
Appendix G · Index
| Look up | Go to |
|---|---|
| Calibration | Unit 4; Appendix A6 |
| Compliance | Unit 4; Appendix A7 |
| Counterfeits | Unit 2; Appendix A5 |
| ESD | Unit 2 |
| Final checklist | Unit 4; Appendix B |
| Formulas | Appendix A2 |
| Hot air | Unit 2; Appendix A4 |
| Isolation set-up | Unit 3 |
| Mistakes | Appendix C |
| Oscilloscope | Unit 1; Appendix A3 |
| Scenarios | Appendix D |
| Switch-mode supplies | Unit 3; Appendix A2 |
| Tools | Appendix E |
Further reading and sources
Best next reads: the service manual of the devices you repair; SparkFun's free hot-air rework tutorial; the hub's Money Skills Level 2 and Entrepreneurial Thinking Level 2; and the Ghana Enterprises Agency's business advisory centres.
What this module does not cover: powered testing of mains units, CRT and microwave repair, BGA reballing, chip-level programming, solar installation and wiring, phones and computers, and Takoradi prices of parts and the Assembly's permit fee for this trade (not verified).
Every source used in this manual is listed, with links, in the Teacher Copy.